Kampmann PowerKon + W Installation Manual

Summary of PowerKon + W

  • Page 1

    I289/06/09/1 gb installation manual retain this manual carefully for future use! Registernummer: 6r1168 wall convectors 1.26 wall models with powerkon heat exchanger.

  • Page 2: 1.26

    Important note important note! Non- observance of this note cannot guarantee the fault-free operation of the unit(s). Table of contents 1. Correct and proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. Safety information. . . . . . . . . . . . . . . . . . . ....

  • Page 3: Wall Convectors

    3 1. Correct and proper use kampmann wall convectors are manufactured in accordance with the state-of-the-art and recognised safety regulations. Personal danger or damage to the equipment or other property can be caused if the equipment is not installed, commissioned and used correctly and properly....

  • Page 4: 1.26

    4 1.26 wall convectors wall models with powerkon heat exchanger installation manual 3. Scope of delivery each wall convector comes with the following components: • 1 no. Wall casing with air outlet through c-profile linear grille 1 or with air outlet through a perforated profile 2 , powdercoated as ...

  • Page 5: Wall Convectors

    5 4. Installation of wall convectors 4.1 fitting brackets g using the wall brackets 1 , mark the drill holes for wall-mounting the unit. Calculate the spacing, as given in fig. 4, using the table below. G a further wall bracket 2 is needed as a central bracket for casing lengths of greater than 1600...

  • Page 6: 1.26

    1 flow connection 1/2” 2 return connection 1/2” 3 air vent 4 thermostatic valve body 1/2” (accessory) 5 thermostatic valve head (accessory) 6 return shut-off valve 1/2” (accessory) 6 1.26 wall convectors wall models with powerkon heat exchanger installation manual 4.2 fitting heat exchanger/water co...

  • Page 7: Wall Convectors

    7 wall convectors 1.26 wall models with powerkon heat exchanger installation manual 4.3 fitting wall casing g place the wall casing with the valve recess so that it fits over the wall brackets and the heat exchanger as shown in fig. 7. Ensure that the spacing dimensions are adhered to, as listed in ...

  • Page 8: 1.26

    8 1.26 wall convectors wall models with powerkon heat exchanger installation manual wall casing depth t mm 70 120 170 220 convector height / depth bh x bt mm 100 x 50 100 x 100 100 x 150 100 x 200 wall casing height h mm 250/400/550/700 fig. 8: dimensions of powerkon + w wall casing length finned co...