Kantech IoPass SA-500 Installation Manual

Manual is about: Stand-Alone Door Controller

Summary of IoPass SA-500

  • Page 1

    Warning: this manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. I o p a s s ™ s t a n d - a l o n e d o o r c o n t r o l l e r i n s t a l l a t i o n m a ...

  • Page 2

    Warning! Please read carefully n o t e t o i n s t a l l e r s this warning contains vital information. As the only individual in con- tact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. S y s t e m f a i l u re s this sy...

  • Page 3

    Limited warranty kantech systems warrants the original purchaser that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, kantech systems shall, at its option, repair or replace any d...

  • Page 5

    V ta b l e o f c o n t e n t s section 1 • introduction to iopass™ 7 1.1 product overview .........................................................7 1.2 about this manual ........................................................7 1.2.1 - new in this version ..............................................

  • Page 6

    Vi.

  • Page 7

    I n t r o d u c t i o n t o i o p a s s ™ - p r o d u c t o v e r v i e w 7 s e c t i o n 1 • i n t r o d u c t i o n t o i o p a s s ™ 1.1 product overview the iopass is a fully programmable stand-alone access control system that allows entry using proximity technology, keypad or both, for up to 5,...

  • Page 8

    I n t r o d u c t i o n t o i o p a s s ™ - specifications 8 1.4 specifications • typical read range—up to 10 cm (4") 1 ; • input voltage—12vdc; • current dc maximum—300ma; • display—16 characters, 2 lines, lcd with backlight; • cards: • access cards—5000 cards • auxiliary cards—20 cards • dimension...

  • Page 9

    I n s t a l l i n g a n d w i r i n g i o p a s s ™ - u n p a c k i n g t h e i o p a s s u n i t 9 s e c t i o n 2 • i n s t a l l i n g a n d wi r i n g i o p a s s ™ 2.1 unpacking the iopass unit check that the following parts are in your iopass package: • one (1) iopass unit (sa-500 or sa-600); ...

  • Page 10

    I n s t a l l i n g a n d w i r i n g i o p a s s ™ - mounting the ioprox p100 reader 10 2.6 mounting the ioprox p100 reader note: for model sa-600 only. To mount the ioprox proximity reader, please refer to installation instructions provided with the reader. Note: if the iopass unit and p100 reader...

  • Page 11

    I n s t a l l i n g a n d w i r i n g i o p a s s ™ - s e t t i n g r e l a y 1 f u n c t i o n s 11 2.11 setting relay 1 functions depending on how you intend to use relay-1, you will need to configure the jumpers, located on the sa-rm56 relay module, before you mount it inside the wall. Note: for ...

  • Page 12: General W

    I n s t a l l i n g a n d w i r i n g i o p a s s ™ - connecting the power 12 general w iring diagram.

  • Page 13

    P r o g r a m m i n g i o p a s s ™ - i n t r o d u c t i o n - i o p a s s p r o g r a m m i n g m o d e 13 s e c t i o n 3 • p r o g r a m m i n g i o p a s s ™ - i n t r o d u c t i o n 3.1 iopass programming mode to enter the programming mode, you have to enter the 6- digit master password follo...

  • Page 14

    P r o g r a m m i n g i o p a s s ™ - i n t r o d u c t i o n - iopass factory defaults 14.

  • Page 15

    P r o g r a m m i n g i o p a s s ™ - f e a t u r e s - a c c e s s m o d e s e l e c t i o n 15 s e c t i o n 4 • p r o g r a m m i n g i o p a s s ™ - f e a t u r e s 4.1 access mode selection before you start registering cardholders, you must select the suitable access mode for your installation....

  • Page 16

    P r o g r a m m i n g i o p a s s ™ - f e a t u r e s - door ajar alarm function 16 (without card or password or both). When this occurs, a “door forced open” type of event is generated. Note: for more information refer to “5.11 configuring the forced entry alarm”, page 24. 4.8 door ajar alarm funct...

  • Page 17

    P r o g r a m m i n g i o p a s s™ - s t e p b y s t e p - s e l e c t i n g t h e s y s t e m l a n g u a g e 17 s e c t i o n 5 • p r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p 5.1 selecting the system language iopass offers users the ability to select the system operating lan- guage. T...

  • Page 18

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - managing passwords 18 5.3.2 - modifying the main password the main password is a “global” password that can be used when access mode “2” is selected. This access mode offers two options: • users present the card to the reader, or • they ent...

  • Page 19

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - a d d i n g & d e l e t i n g c a r d s 19 5.4 adding & deleting cards up to 5,000 cards can be stored in the unit (plus 20 auxiliary cards). Note: once you have selected the “access mode”, you may start enrolling cards. Otherwise, please r...

  • Page 20

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - viewing cards 20 to add/delete a group of cards: 1. Enter the master password (default is [111111]) fol- lowed by the [#] key. The lcd displays the follow- ing: 1. Enroll 2. Passwd 3. Timer 4. System 2. Press [1-enroll]. The lcd displays: 1...

  • Page 21

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - v e r i f y i n g a c a r d n u m b e r 21 3. Press [1-access card] to view access cards or press [2-aux. Card] to view auxiliary cards . The lcd displays: 1. Program cards 2. View cards 4. Press [2-view cards]. The lcd displays: xxxx id_xx...

  • Page 22

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - auxiliary function configuration (relay-1) 22 to disarm the system: 1. Enter the guard code [123] followed by the [#] key. 2. The lcd prompts for a card: card please 3. Present a card to the reader then enter the cardholder’s pin (any card ...

  • Page 23

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - c o n f i g u r i n g t h e d u r e s s f u n c t i o n ( r e l a y - 1 ) 23 5.9 configuring the duress function (relay-1) the duress function is used to provide added security to personnel. In situations of duress, a cardholder enters his ...

  • Page 24

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - configuring the forced entry alarm 24 5.10.2 - using the tamper alarm function once the function is enabled in the system, follow this procedure to stop the tamper alarm if it has been activated. 1. When the tamper alarm has been activated,...

  • Page 25

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - p i n e r r o r f u n c t i o n c o n f i g u r a t i o n 25 5.12.2 - activating the alarm relay on door ajar 1. Enter the master password (default is [111111]) fol- lowed by the [#] key. The lcd displays the follow- ing: 1. Enroll 2. Passw...

  • Page 26

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - beeper key tone configuration 26 1. Enroll 2. Passwd 3. Timer 4. System 2. Press [4-system]. The lcd displays: 1.Alarm 2.Check 3.Mode 4.Other 3. Press [4-other]. The lcd displays: 1.Tone 2.Duress 3.More 4. Language 4. Press [3-more]. The lc...

  • Page 27

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - s e t t i n g t h e s t r i k e r e l a y t i m e r 27 3.Duress 4.Ajar 3. Press [2-alarm]. The lcd displays: current: 240 sec. New: 4. Using the keypad, enter the number of seconds during which the alarm will sound. Enter digits in “seconds...

  • Page 28

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - resetting the iopass unit to factory defaults 28 quick reference programming table 1.Enroll 1.Access card program cards 1.S_add view cards 2.S_del 3.B_add 4.B_del 2.Aux. Card program cards 1.S_add view cards 2.S_del 2.Passwd 1.Master 2.Main...

  • Page 29: Programming Worksheet

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - r e s e t t i n g t h e i o p a s s u n i t t o f a c t o r y d e f a u l t s 29 programming worksheet system passwords access mode [4]-[3]-[1] mode “0” - card only (default) mode “1” - card and pin mode “2” - card or main password timers n...

  • Page 30

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - resetting the iopass unit to factory defaults 30 card information record sheet note: make copies of this sheet to record cardholder information. Cardholder name card number auxiliary card pin (if used) i_____i_____i_____i_____i_____i_____i_...

  • Page 31: Using The Iopass™ System

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - r e s e t t i n g t h e i o p a s s u n i t t o f a c t o r y d e f a u l t s 31 using the iopass™ system by default, the led (indicator) is red, and the lcd of the iopass unit displays: ready for card you may have been given an access card...

  • Page 32

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - resetting the iopass unit to factory defaults 32 ready for card door open 2. The “door open” message is displayed (and blinking) and will remain on the lcd until the door is closed properly. Once the function is enabled in the system, follo...

  • Page 33

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - r e s e t t i n g t h e i o p a s s u n i t t o f a c t o r y d e f a u l t s 33.

  • Page 34

    P r o g r a m m i n g i o p a s s ™ - s t e p b y s t e p - resetting the iopass unit to factory defaults 34.

  • Page 36

    Kantech systems tel: +1(978) 731-6252 • toll free: us & canada: 1 888 222-1560 • fax: +1(978) 731-7759 web site: www.Kantech.Com e-mail: techlink@tycoint.Com © 2003, kantech systems. All rights reserved. Specifications may be modified without notice. ™ trademarks of kantech systems. Printed in usa •...