Each time before operating
the cleaner
n
Check connecting cable for damage
(risk of getting an electric shock), have
a damaged connecting cable replaced
without delay by authorised Customer
Service personnel or an electrician.
n
Check high-pressure hose for damage
(danger of explosion), replace
a damaged high-pressure hose without
delay.
n
Check cleaner (pump) for any leaks.
3 drops per minute are allowable and
can appear on the underside of the
cleaner. Seek the help of Customer
Service if leaks are more serious.
Every week
n
Check oil level in oil reservoir: if the oil is
milky (water in oil), seek the help of
Customer Service immediately.
n
Clean strainer at the water connection.
n
Clean the filter at the suction hose for
detergent.
Annually or after 500
operating hours
n
Change the oil
– For oil quantity and type see
Technical Specifications.
– Undo fastening screws, remove unit
cover, remove cover of oil reservoir.
– Lay cleaner on its side and drain oil
into a suitable container.
– Fill slowly with fresh oil; air bubbles
have to escape.
Emptying and cleaning the
detergent tank
n
Pull out the screw cap and hose for
the detergent tank.
n
Loosen the tank holder and overturn
the tank.
n
Empty and clean the tank.
Troubleshooting
Danger!
Before any repair work is undertaken,
switch the cleaner off and pull out the
power plug. Have electrical
components checked and repaired
only be authorised Customer Service
personnel.
For faults which are not identified in
this chapter, or when in doubt or
when expressly instructed to do so,
consult authorised Customer Service
personnel.
Cleaner does not work
n
Check mains voltage.
n
Check connecting cable for damage.
n
If the motor has overheated, let the
cleaner cool down. Then switch it on
again.
n
Consult Customer Service if there is an
electrical fault.
Cleaner does not come up to
pressure
n
Set nozzle to “high pressure”.
n
Clean nozzle or replace with new one.
n
Clean strainer at the water connection.
n
Evacuate air from the cleaner.
n
Check water inlet volume (see Technical
Specifications).
!
5959-797.book Seite 20 Dienstag, 7. Januar 2003 12:02 12