English 5.906-757.0 rev. 00 (10/15) 1 ivc 60/24-2 tact² service manual.
2 english 5.906-757.0 rev. 00 (10/15) contents preface 3 safety instructions 3 hazard levels 3 description in this service manual 4 service groups 4 functional group structure 4 textual description 4 technical features 4 field of application 4 safety installations 4 type plate 4 parts of the system ...
English 5.906-757.0 rev. 00 (10/15) 3 060 error diagnosis 18 070 peculiarities/ others 18 technical documentation 19 technical specifications 19 circuit diagram 20
4 english 5.906-757.0 rev. 00 (10/15) good service work requires extensive and practice-orient- ed training as well as well-structured training materials. Hence we offer regular basic and advanced training pro- grammes covering the entire product range for all service engineers. In addition to this,...
English 5.906-757.0 rev. 00 (10/15) 5 example: install/uninstall anra wheel axle observe the allocation of service groups to the appliance components in the overview diagram in chapter "overview over the service and functional groups". instruction preparatory operations 1 2 key numerical a b key...
6 english 5.906-757.0 rev. 00 (10/15) 1 power switch 2 instrument panel 3 intermediate ring 4 sediment container 5 suction head 몇 warning switch off the appliance and remove the plug from the socket. Observe general safety information! No special functional characteristics. Parts of the system front...
English 5.906-757.0 rev. 00 (10/15) 7 note unless otherwise described, the installation takes place in reverse order. abit uninstall / install instrument panel 1 screw 2 handle loosen screws. remove the handle. 1 screws 2 cover filter open the cover of the filter. unscrew the screws. 1 ele...
8 english 5.906-757.0 rev. 00 (10/15) 1 instrument panel 2 hood note mind the wiring when removing the cover. thread the instrument panel through the opening of the cover. remove the hood. Installation information upon reinstallation, make sure that no cables are jammed! 1 screws 2 instrument pa...
English 5.906-757.0 rev. 00 (10/15) 9 acsk uninstall / install suction head 1 screws 2 intermediate ring 3 side plate remove the sediment container. unscrew the screws. remove side plate. 1 intermediate ring 2 screws 3 machine frame unscrew the screws. remove intermediate ring. Service g...
10 english 5.906-757.0 rev. 00 (10/15) 몇 warning switch off the appliance and remove the plug from the socket. Observe general safety information! No special functional characteristics. Note unless otherwise described, the installation takes place in reverse order. 1 nut 2 electric connectors unsc...
English 5.906-757.0 rev. 00 (10/15) 11 1 lock latches 2 suction head open lock latches. remove the suction hand. abha uninstalling / installing cover 1 screws 2 control electronics 2 unscrew the screws. remove control electronics 2. 1 screw loosen screws. Acst uninstall/ install suction ...
12 english 5.906-757.0 rev. 00 (10/15) 1 screws unscrew the screws. 1 electrical socket plug connections (suction turbine 1) 2 electrical socket plug connections (suction turbine 2) separate the electric connectors. Note observe the connection diagram. 1 screws 2 casing suction turbine 3 suction...
English 5.906-757.0 rev. 00 (10/15) 13 1 handle 2 locking 3 cover filter pull on the lock. open the cover of the filter. 1 flat fold filter remove flat folded filter. abha uninstalling / installing cover 1 screws 2 cover tact unit unscrew the screws. remove cover tact unit. Acff uninstal...
14 english 5.906-757.0 rev. 00 (10/15) 1 tact magnets 2 tact unit remove tact magnets. remove tact unit. 1 screwdriver 2 locking nose 3 casing cover tact unit detach the tact unit from the latches using a screwdriv- er. remove casing cover of the tact unit. 1 sealings 2 guide tact magnets 3 ...
English 5.906-757.0 rev. 00 (10/15) 15 abha uninstalling / installing cover 1 screws 2 cover tact unit unscrew the screws. remove cover tact unit. 1 tact magnets 2 electric socket plug connections 3 electric screw connections separate the electric connectors. disconnect electric screw conn...
16 english 5.906-757.0 rev. 00 (10/15) 몇 warning switch off the appliance and remove the plug from the socket. Observe general safety information! No special functional characteristics. Note unless otherwise described, the installation takes place in reverse order. acsk uninstall / install suction...
English 5.906-757.0 rev. 00 (10/15) 17 1 screw connection 2 plug disconnect screw connection. 1 level sensor 2 union joint 3 intermediate ring unscrew the covering nut. pull the filling level sensor out of the intermediate ring. abit uninstall / install instrument panel 1 electric socket plu...
18 english 5.906-757.0 rev. 00 (10/15) abha uninstalling / installing cover 1 power switch 2 electric socket plug connections separate the electric connectors. 1 screws 2 cord grip 3 mains cable unscrew the screws. remove strain relief. remove mains cable. Note mind correct installation of...
English 5.906-757.0 rev. 00 (10/15) 19 ahse uninstall / install control electronics 1 1 screws 2 control electronics 2 disconnect all electrical connections. unscrew the screws. remove control electronics 2. Note observe the connection diagram. Service group does not contain any maintenance ...
20 english 5.906-757.0 rev. 00 (10/15) technical documentation appliance type appliance no. Operating instructions spare parts list ivc 60/24-2 tact² 1.576-100.0 5.963-949.0 5.971-299.0 technical specifications ivc 60/24-2 *eu *ch ivc 60/24-2 *gb mains voltage v 220-240 110 frequency hz 1~ 50/60 1~ ...
English 5.906-757.0 rev. 00 (10/15) 21 circuit diagram.
22 english 5.906-757.0 rev. 00 (10/15) b1 level sensor h1 indicator lamp l1 magnet l2 magnet m1 suction turbine m2 suction turbine n1 control electronics 1 n2 control electronics 2 s1 power switch x1 mains plug x2 terminal strip x4 plug socket contacts filling level sensor x5 plug pin contacts filli...