    2 dear customer, we want to thank you for choosing one of our production stoves for your purchase. We are confident that we supplied you with a technologically valid product. In the following pages, we provide you with some instructions, so that you may know and use the product at its best, as well ...

  • Page 3

    3 a. General information a.1 general safety rules a.2 technical features a.3 accessory equipment a.4 identity plate a.5 guarantee a.6 suitable fuel a.7 ordering spares a.8 waste material b. Installation instructions b.1 initial warnings b.2 moving and transporting b.3 positioning b.4 installing the ...

  • Page 4

    4 d.7 room probe d.8 sparking plug d.9 thermocouple e. Ordinary cleaning and maintenance e.1 cleaning and maintenance by the customer e.2 periodic maintenance by the assistance center f. Alarms displaying f.1 fumes temperature probe alarm f.2 unsuccessful lighting alarm f.3 switching-off while worki...

  • Page 5

    5 a. General information a.1 general safety rules attention please!!! You can never be too cautious: before the installation read and comply with these fundamental rules:  all local regulations, including those referring to national and european laws, must be respected while installing the stove. ...

  • Page 6

    6 ● in order to facilitate the possible interventions by the technical assistance, do not fit the stove inside closed spaces and do not place it adjacent to the walls, for this may compromise the correct afflux of the air. ● the lack of draught by the flue (or, for instance, the obstruction or closi...

  • Page 7

    7 a.2 technical features in the following pages, we provide you with a list explanatory of the technical features: pellet stove “elena” nominal power: 10kw efficiency: 87% power supply: 230v 50hz power absorption: 90-270w pellet tank capacity: 20kg co measured at 13% of oxygen at nominal thermal pow...

  • Page 8

    8 pellet stove “lisa” nominal power: 8kw efficiency: 85% power supply: 230v 50hz power absorption: 90-230w pellet tank capacity: 15kg pellet consumption (kg/h): 1,6kg/h co (measured at 13% of oxygen at nominal thermal power) 0,01% exhausted gas temperature at nominal thermal power: medium 187°c - ma...

  • Page 9

    9.

  • Page 10

    10

  • Page 11

    11.

  • Page 12

    12 a.3 accessory equipment the stove is equipped with: - a remote control; - a supply cable; - adjustable feet; - a handbook. A.4 identity plate the identity plate is positioned on the back of the stove, and it reports the following data: - commercial brand - supply tension - serial number - absorbe...

  • Page 13

    13 a.6 suitable fuel the stove functions solely by pellets, a cylinder-shaped fuel made out of a mixture of various wooden materials; pellets are compliant to din 51731 regulations. The following list summarizes the main characteristics of recommended pellets: diameter 6-6,5mm maximum length 20-25mm...

  • Page 14: B. Installation Instructions

    14 b. Installation instructions b.1 initial warnings the device must be installed on a pavement that presents an adequate burden capacity. If the existing building does not satisfy this requirement, appropriate measures (for instance a burden distribution plate) must be taken. The installation of th...

  • Page 15

    15 b.4 installing the flue gas outlet the installation can be performed either without a masonry flue, or with an existing flue. Fig 1. Installation without a masonry flue flue gas outlet Ø 80 – using an easy to inspect t-joint, reach the outside of the building horizontally; proceed vertically unti...

  • Page 16

    16.

  • Page 17

    17 b.5 installing the combustion air inlet pipe for any described solution, two alternatives are possible: ● draw the air directly from the outside through a piping (internal Ø 50mm; max length 1,5m), connected to the air inlet pipe on the back of the stove. ● draw the air directly from the installa...

  • Page 18

    18 electrical scheme.

  • Page 19: C.1 Initial Warnings

    19 c. Operating instructions c.1 initial warnings all regulations, included those referring to national and european laws, must be respected when installing the device. Do not use the device as an incinerator or in any other way than that for which it was designed. Do not use any fuel other than pel...

  • Page 20

    20 c.3 display in the following scheme, we report the various functions of the display. Important: if the temperature is not set within a few seconds, the display will automatically return to the previous screenshot..

  • Page 21

    21 c.4 lighting the stove for the first time a skilled technician must perform the first lighting; otherwise, the guarantee will expire. C.5 activating the stove when the pellet tank is filled for the first time, you must remember that the screw tube, which feeds the grate, is completely empty; ther...

  • Page 22

    22 c.7 switching off the stove you can switch the stove off by pushing the key n. 4 for a few seconds. The message “off” will appear on the display; the pellet flow is interrupted and the speed of the smoke intake motor will increase to lower the temperature. The stove will complete its cycle and wi...

  • Page 23

    23 c.9 managing the automatic lighting (chronothermostat) the automatic lighting function permits to weekly program the lighting and switching off of the stove. Through this function, it is possible to set two daily lightings; it is also possible to avoid extra programming, by memorizing the set dat...

  • Page 24

    24 ut08/ut09: they indicate the starting and stopping time of the program 2, if the ut01 setting is set on the weekly mode (different from off) ut10: it modifies the weekdays you wish the program 2 to be on. By pressing the “2” key you run over the days, and by pressing the “1” key you set or unset ...

  • Page 25

    25 a9 settings description lisa’s value elena’s values monica’s values pr 01 maximum time for the lighting (in minutes) 15’ 15’ 15’ pr 02 time for the stabilization of the flame during the starting phase “fire on” (in minutes) 06’ 06’ 06’ pr 03 time break between the cleanings of the grate (in minut...

  • Page 26: Components

    26 d. Functions of the mechanical and electric components d.1 screw motor the screw motor drives the screw, which brings the pellets from the tank to the grate. D.2 smoke intake motor the smoke intake motor is fixed on the extraction turbine on the back of the stove. Its function is to intake and to...

  • Page 27

    27 d.6 fumes probe the fumes probe surveys the fumes’ temperature in the intake turbine, and it operates when the temperature reaches 270°c, driving the stove to the conservation mode “ris” d.7 room probe the room probe is positioned on the back of the stove and it surveys the temperature of the roo...

  • Page 28

    28 e. Ordinary cleaning and maintenance e.1 cleaning and maintenance by the costumer before lighting the stove, it is advisable to clean the inside of the stove. ● open the door and vacuum the fire table. ● remove the great, verify its cleanliness and clean the holes if necessary. ● vacuum the grate...

  • Page 29: F. Alarms Displaying

    29 f. Alarms displaying the alarms are displayed on the command panel; on the first line the message alar appears, while on the second line the typology of the anomaly is displayed. The occurring of an alarm provokes the immediate stop of the stove, and only after solving the problem it is possible ...

  • Page 30

    30 g. Solution to possible problems problem possible cause solutions the display is blank and the keys do not work. Lack of power. Anomalies in the connection between the display and the card. Check if the power supply cable is connected. Check if the display and the card are properly connected. The...

  • Page 31

    31 problem possible cause solutions the stove is blocked for an unsuccessful pellet supply. Technical problem with the screw. Important: unplug the stove before - ridding the screw of possible obstructions - ridding the chute of possible obstructions - removing the pellet dust accumulation from the ...

  • Page 32: Guarantee Conditions:

    Guarantee conditions: at the end of each season, it is obligatory to have the authorized assistance center perform a general cleaning of the module; otherwise, the guarantee will expire..