Karmek One ALICE CANALIZZATA Operating And Maintenance Handbook

Manual is about: CHANNELED PELLET STOVE

Summary of ALICE CANALIZZATA

  • Page 1

    Channeled pellet stove alice canalizzata operating and maintenance handbook.

  • Page 2

    2 dear customer, we want to thank you for choosing one of our production stoves for your purchase. We are confident that we supplied you with a technologically valid product. In the following pages, we provide you with some instructions, so that you may know and use the product at its best, as well ...

  • Page 3

    3 a. General information a.1 general safety rules a.2 technical features a.3 accessory equipment a.4 identity plate a.5 guarantee a.6 suitable fuel a.7 ordering spares b. Installation instructions b.1 initial warnings b.2 moving and transporting b.3 positioning b.4 channeling b.5 installing the flue...

  • Page 4

    4 d. Functions of the mechanical and electric components d.1 screw motor d.2 smoke intake motor d.3 tangential fan d.4 centrifugal fan d.5 electronic card d.6 general switch d.7 fumes probe d.8 room probe d.9 sparking plug d.10 thermocouple e. Ordinary cleaning and maintenance e.1 cleaning and maint...

  • Page 5

    5 a. General information a.1 general safety rules attention please!!! You can never be too cautious: before the installation read and comply with these fundamental rules: ● all local regulations, including those referring to national and european laws, must be respected while installing the stove. ●...

  • Page 6

    6 ● in order to facilitate the possible interventions by the technical assistance, do not fit the stove inside closed spaces and do not place it adjacent to the walls, for this may compromise the correct afflux of the air. ● the lack of draught by the flue (or, for instance, the obstruction or closi...

  • Page 7

    7 mental abilities or low experience and knowledge, unless they have been supervised or educated to the use of the appliance by the person who is responsible for its security. A.2 technical features nominal power: 12kw average efficiency: 88% heating capacity: 280-310m³ power supply: 230v 50hz nomin...

  • Page 8

    8 1 side fumes outlet 2 top fumes outlet 3 rear fumes outlet 4 combustion air inlet 5 switch and power socket 6 channeled air outlet.

  • Page 9

    9 a.5 guarantee the guarantee certificate, which we consigned to you when you purchased the stove, must be sent to the producer firm karmek one srl, 8 days after delivery date the latest; otherwise, the guarantee itself will no longer be valid. The estimated 24-months guarantee is valid exclusively ...

  • Page 10

    10 b. Installation instructions b.1 initial warnings the device must be installed on a pavement that presents an adequate burden capacity. If the existing building does not satisfy this requirement, appropriate measures (for instance a burden distribution plate) must be taken. The installation of th...

  • Page 11

    11 b.4 channeling the stove is able to convey a part of the heat in another environment through a lever in the lower front of the stove. If the switch remains in the open position (right) the heated air is pumped only from the front top and bottom of the stove. If the switch remains in the closed po...

  • Page 12

    12.

  • Page 13

    13 b.6 installing the combustion air inlet pipe for any described solution, two alternatives are possible: ● draw the air directly from the outside through a piping (internal Ø 50mm; max length 1,5m), connected to the air inlet pipe on the back of the stove. ● draw the air directly from the installa...

  • Page 14

    14 electrical scheme.

  • Page 15: C.1 Initial Warnings

    15 c. Operating instructions c.1 initial warnings all regulations, included those referring to national and european laws, must be respected when installing the device. Do not use the device as an incinerator or in any other way than that for which it was designed. Do not use any fuel other than pel...

  • Page 16

    16 c.3 user menu press the p3 key (menu) to access the menu. The menu has various voices and levels that allow access to the settings and to the programming of the stove. Each level is reached by selecting an item and pressing the p3 key. To go through the items list use the p1 and 2 or 5 and 6 keys...

  • Page 17

    17 05 - tuesday prog 1 on/off 06 - wednesday prog 1 on/off 07 - thursday pog 1 on/off 08 - friday prog 1 on/off 09 - saturday prog 1 on/off 10 - sunday prog 1 on/off 11 - start prog 2 time 12 - stop prog 2 time 13 - monday prog 2 on/off 14 - tuesday prog 2 on/off 15 - wednesday prog 2 on/off 16 - th...

  • Page 18

    18 05 - stop 2 04 - select language 01 - italiano set 02 - francais set 03 - english set 04 - deutsch set 05 - mode stand-by on/off 06 - buzzer on/off 07 - load initial set 08 - state stove - c.4 adjust blowers allows the adjustment of the two fans independently. The following settings are available...

  • Page 19

    19 c.5 set clock sets current time and date. The motherboard clock is fitted with a lithium battery that grants 3/5 years of operating time. C.6 set chrono - enable chrono switches on or off all chronothermostat functions. - program day enables, disables and sets daily chronothermostat functions. It...

  • Page 20

    20 selezione significato valori possibili start 1 ora di attivazione ora - off stop 1 ora di disattivazione ora - off start 2 ora di attivazione ora - off stop 2 ora di disattivazione ora - off - program week enables, disables and sets weekly chronothermostat functions. The weekly programmer feature...

  • Page 21

    21 program 2 menu level selection meaning allowed values 03-03-11 start prog 2 lighting time time - off 03-03-12 stop prog 2 switching off time time - off 03-03-13 monday prog 2 d ay o f ap p li ca ti o n on/off 03-03-14 tuesday prog 2 on/off 03-03-15 wednesday prog 2 on/off 03-03-16 thursday prog 2...

  • Page 22

    22 - program week-end enables, disables and sets chronothermostat functions for the week-end (saturday and sunday, days 5 and 6). Tip: the programming function features fairly elaborate procedures. It is advisable to activate one weekly program at a time. Avoid enabling daily, weekly and week-end pr...

  • Page 23

    23 c.10 - load initial this mode, that should be used only before lighting and with the stove cooled down, allows to charge the grate with pellet for 90”. Start charging with p1 key and stop with p4. C.11 - state stove displays the state of the stove reporting information about the various devices c...

  • Page 24

    24 c.12 failed lighting if the time set in pr01 is exceeded and fumes temperature did not reach the minimum allowed value set in pr13 with a rate of 2°vc/min, the stove goes into an alarm state. C.13 working phase once lighting phase ends correctly, the stove enters working mode, that is the normal ...

  • Page 25: Components

    25 d. Functions of the mechanical and electric components d.1 screw motor the screw motor drives the screw, which brings the pellets from the tank to the grate. D.2 smoke intake motor the smoke intake motor is fixed on the extraction turbine on the back of the stove. Its function is to intake and to...

  • Page 26

    26 d.6 general switch this electronic component of the stove is composed by a 4a fuse and by an electronic filter that protect the stove from electrical overload and electromagnetic inconveniencies. D.7 fumes probe the fumes probe surveys the fumes’ temperature in the intake turbine, and it operates...

  • Page 27

    27 e. Ordinary cleaning and maintenance e.1 cleaning and maintenance by the costumer before lighting the stove, it is advisable to clean the inside of the stove. ● open the door and vacuum the fire table. ● remove the great, verify its cleanliness and clean the holes if necessary. ● vacuum the grate...

  • Page 28: F. Alarms Displaying

    28 f. Alarms displaying if a malfunction occurs the motherboard signals the problem and performs different actions based on the type of the alarm. The following table lists all possible alarms and the condition or device that causes each one. Alarm origin message displayed fumes probe alarm sond fum...

  • Page 29: G. Waste Material

    29 f.4 alarm for absence of fire while in working phase this alarm is activated if during working phase the fire goes off and fumes temperature falls below the minimum treshold set in pr13 parameter. F.5 alarm caused by failure of the fumes motor this alarmi ensues when the smoke intake motor fails....

  • Page 30

    30 g. Solution to possible problems problem possible cause solutions the display is blank and the keys do not work. Lack of power. Check if the power supply cable is connected. Anomalies in the connection between the display and the card. Check if the display and the card are properly connected. The...

  • Page 31

    31 problem possible cause solutions the stove is blocked for an unsuccessful pellet supply. Technical problem with the screw. Important: unplug the stove before - ridding the screw of possible obstructions - ridding the chute of possible obstructions - removing the pellet dust accumulation from the ...

  • Page 32: Guarantee Conditions:

    Alice canalizzata handbook – rev. 00 310513 legal head office: via martiri delle foibe, 17 31015 conegliano (tv) phone 0438 1883101 fax 0438 1883103 e-mail info@karmek.It guarantee conditions: at the end of each season, it is obligatory to have the authorized assistance center perform a general clea...