Kasco Marine 3.1JF Owner's Manual

Manual is about: aerating fountain

Summary of 3.1JF

  • Page 1

    Kasco marine, inc. 800 deere rd. Prescott, wi 54021 phone (715) 262-4488 * fax (715) 262-4487 www.Kascomarine.Com * sales@kascomarine.Com contents safety instructions …………………………………….. General owner’s instructions………………………….. 8400jf parts included, tools needed, & unit specs….. 3.1jf parts included, ...

  • Page 2

    We at kasco marine, inc. Would like to both thank and congratulate you on your purchase of the jf model aerating fountain. We appreciate you choosing kasco and for your purchase. Your decision to purchase kasco’s 8400jf, 3.1jf, or 5.1jf aerating fountain will not disap- point you. The jf series aera...

  • Page 3: Inspect The Shipment

    General owner’s instructions inspect the shipment immediately inspect your kasco fountain shipment for any visible damages. Also cross reference the parts supplied with the parts included sheet to check for shortages. Shortages should be reported im- mediately to your kasco marine distributor or rep...

  • Page 4: 8400Jf Parts Included

    8400jf parts included a. 8400jf aerating fountain (unit with cord or unit with disconnect) (1) a1. Cord in separate box (1) (depending on size of cord) b. Float in separate box (1) (diagram to right) 1. 3 float sections (1) 2. Top float bracket (3) 3. Bottom float bracket w/ 50’ rope (3) 4. 9” x 3/8...

  • Page 5: 3.1Jf Parts Included

    3.1jf parts included a. 3.1jf aerating fountain (unit with cord or unit with disconnect) (1) a1. Cord in separate box (1) (depending on size of cord) b. Float in separate box (1) (diagram to right) note: if you purchased 6 lights, refer to 5.1jf float assembly . 1. 3 float sections (1) 2. Top float ...

  • Page 6

    84000jf & 3.1jf assembly and installation instructions step one remove all contents from package and place on a clean, flat surface. Inspect the shipment for any dam- ages. If damages are found, immediately notify your carrier and your kasco marine, inc. Representative. Next, cross reference the par...

  • Page 7

    Step seven position the bottom screen (part #b9) over the float so the motor housing (can) passes through the large hole in the center of the screen. Remove the center three 3/8” lock nuts from the 9” bolts and place the bottom screen clips (part #b13) over the bolts as shown. The power cord can be ...

  • Page 8

    Step fourteen hardwire the 240v/208v, 4 wire service into the c- 85 control panel per the instructions on page 14 of this manual. The aerating fountain can either be plugged into the 240v outlet on the right hand side of the c-85 panel or hardwired into the panel. Plug: insert the plug on the unit i...

  • Page 9: 5.1Jf Parts Included

    5.1jf parts included a. 5.1jf aerating fountain (unit with cord or unit with disconnect) (1) a1. Cord in separate box (1) (depending on size of cord) b. Float in separate box (1) (diagram to right) 1. 3 float sections (1) 2. Top float bracket (3) 3. Bottom float bracket w/ 50’ rope (3) 4. 9” x 3/8” ...

  • Page 10

    5.1jf assembly and installation instructions step one remove all contents from package and place on a clean, flat surface. Inspect the shipment for any dam- ages. If damages are found, immediately notify your carrier and your kasco marine, inc. Representative. Next, cross reference the parts include...

  • Page 11

    Step seven position the bottom screen (part #b9) over the float so the motor housing (can) passes through the large hole in the center of the screen. Remove the center three 3/8” lock nuts from the 9” bolts and place the bottom screen clips (part #b13) over the bolts as shown. The power cord can be ...

  • Page 12

    Step fourteen hardwire the 240v/208v, 4 wire service into the c- 95 control panel per the instructions on page 15 of this manual. The aerating fountain must be hard- wired into the panel. Hardwire: the bottom of the c-95 control panel has several knock-outs for hardwiring the unit. Re- move a knock-...

  • Page 13: Redwood

    Nozzle options & pattern sizes note: pattern sizes listed are approximate. Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes. • all five (or six) nozzles are included with the package. • the linden, willow, and...

  • Page 14: Model: C85

    Model: c85 display aerator control with time switch, gfcb, lightning arrestor and 15 amp gfci lighting receptacle suitable for use with submersible lights in rainproof (type 3r) enclosure suitable for indoor or outdoor use 40 amp. Max per leg 120/240 volt single phase (three wire) ac pump circuit: 3...

  • Page 15: Model: C95

    Model: c95 display aerator control with time switch, gfcb, lightning arrestor and 15 amp gfci lighting receptacle suitable for use with submersible lights in rainproof (type 3r) enclosure suitable for indoor or outdoor use 40 amp. Max per leg 120/240 volt single phase (three wire) ac pump circuit: 2...

  • Page 16: Maintenance Recommendations

    Maintenance recommendations ** under no circumstances should anyone enter the water while a fountain is operating. ** ** please keep the original box for maintenance shipping. ** the following maintenance procedures can be utilized to ensure many years of quality performance from your kasco fountain...

  • Page 17

    Warranty, warranty claim, & return policy 2 year limited warranty: kasco ® marine, inc. Warrants this fountain to be free from defects in material or workmanship (except for the ropes, power cord, and propeller) under normal use and service. The kasco marine, inc. Obligation under this warranty is l...

  • Page 18

    Once the warranty coverage has been established, the unit may be sent to any kasco authorized repair center for evaluation and repair. Please call kasco marine at 715-262-4488 prior to shipping to receive a return authorization number and/or repair form, then ship to: kasco marine, inc. 800 deere rd...

  • Page 19

    6 1 3 14 13 2 15 4 11 12 9 10 5 8 18 16 20 17 21 19 22 23 7 8400j replacement parts item no. Part no. Description qty. 1 840250 jet pump housing 1 2 840260 impeller, 8400 1 3 840240 2 hp housing cone 1 4 840220 8400 jet/ pump base 1 5 820700 assembly, black top, 8400 1 6 475628 screw, fillister head...

  • Page 20

    5 1 3 12 11 2 13 4 9 10 7 8 16 14 18 15 19 17 20 21 6 3.1j replacement parts item no. Part no. Description 3 hp/qty. 1 840250 jet pump housing 1 2 840360 impeller, 3 hp 1 3 840240 2 hp housing cone 1 4 840220 8400 jet/ pump base 1 5 475628 screw, fillister head 3 6 990275 o ring, cord 1 7 990280 sea...

  • Page 21

    5 1 3 12 11 2 13 4 9 10 7 8 16 14 18 15 19 17 20 21 6 5.1j replacement parts item no. Part no. Description qty. 1 840550 5.1 j housing 1 2 840560 impeller, 5 hp 1 3 840558 cone, 5.1j 1 4 840220 8400 jet/ pump base 1 5 475628 screw, fillister head 3 6 990275 o ring, cord 1 7 990280 sealing plug 1 8 9...

  • Page 22: Troubleshooting Tips

    Troubleshooting tips below are some helpful troubleshooting tips. If a problem occurs, please double check the assembly and in- stallation instructions as well as the instructions for the proper control panel. More troubleshooting tips can be found at www.Kascomarine.Com/general_info_troubleshooting...

  • Page 23

    800 deere rd. Prescott, wi 54021 phone: 715-262-4488 - fax: 715-262-4487 www.Kascomarine.Com sales@kascomarine.Com kasco repair sheet — customer info. * important reminders * • all repairs sent in must be accompanied by a copy of this completed sheet! • routine maintenance consists of checking the z...

  • Page 24: Kasco Marine, Inc.

    Kasco marine, inc. 800 deere rd. Prescott, wi 54021 phone (715) 262-4488 * fax (715) 262-4487 www.Kascomarine.Com * sales@kascomarine.Com * service@kascomarine.Com 24 fountain warranty information please register your fountain online at www.Kascomarine.Com/general_info_warranty_registration.Htm also...