Kathrein DCM 32 Operating Manual

Manual is about: Kathrein Cable Modem Operating Manual

Summary of DCM 32

  • Page 1

    Bedienungsanleitung operating manual mode d'emploi kabelmodem cable modem modem câble dcm 32 dcm 42 / 42 i bestell-nr./ order no./ référence: 26210042 26210043 26210044.

  • Page 2

    2.

  • Page 3: Inhalt / Contents / Sommaire

    Inhalt / contents / sommaire 3 inhalt / contents / sommaire inhalt / contents / sommairevorwort ............................................................. 3 vorwort.............................................................................................................. 6 anschlüsse und anzei...

  • Page 4: Inhalt / Contents / Sommaire

    Inhalt / contents / sommaire 4 anschlussschema.......................................................................................... 17 preface ............................................................................................................ 18 connections and displays...................

  • Page 5: Inhalt / Contents / Sommaire

    Inhalt / contents / sommaire 5 branchements et affichages ......................................................................... 31 consignes de sécurité ................................................................................... 32 remarques importantes concernant l'utilisation.............

  • Page 6: Vorwort

    Vorwort 6 vorwort sehr geehrter kunde, die neuen kabelmodems dcm 32 (docsis), dcm 42 und dcm 42 i (eurodocsis) *) von kathrein bieten ihnen über den breitbandka- bel-anschluss einen hochgeschwindigkeitszu- gang ins internet. Sie verfügen damit über eine äußerst schnelle verbindung ins internet und i...

  • Page 7: Anschlüsse Und Anzeigen

    Anschlüsse und anzeigen 7 anschlüsse und anzeigen leds (erklärung auf seite 14 ff) 1 2 3 4 1 stromversorgung 12 v 2 hf-buchse (f-buchse) 3 ethernet-buchse 4 usb-buchse.

  • Page 8: Sicherheitshinweise

    Sicherheitshinweise 8 sicherheitshinweise wichtige hinweise zum betrieb im folgenden abschnitt finden sie wichtige hin- weise zum betrieb, aufstellungsort und an- schluss des modems. Lesen sie diese hinweise sorgfältig, bevor sie das gerät in betrieb nehmen. Längere abwesenheit/gewitter trennen sie ...

  • Page 9: Sicherheitshinweise

    Sicherheitshinweise 9 reparatur lassen sie reparaturen nur von qualifiziertem fachpersonal ausführen. Eigenmächtiges Öffnen und reparaturversuche führen zu garantiever- lust. Durch unsachgemäße eingriffe am gerät kann die elektrische sicherheit gefährdet werden. Der hersteller haftet nicht für unfäl...

  • Page 10: Aufstellungsort Und Montage

    Aufstellungsort und montage 10 aufstellungsort und montage aufstellungsort jedes elektronische gerät entwickelt wärme. Die erwärmung liegt jedoch in einem ungefährlichen bereich. Empfindliche möbeloberflächen und furniere können sich durch die ständige wärme- einwirkung im laufe der zeit leicht verf...

  • Page 11: Aufstellungsort Und Montage

    Aufstellungsort und montage 11 netzspannung betreiben sie das modem über das mitgelieferte steckernetzteil nur an einer netzspannung von 230 v/50 hz. Das gerät darf erst an das netz angeschlossen werden, nachdem die verbindun- gen mit der antennensteckdose und dem pc hergestellt wurden. Erdung die h...

  • Page 12: Installation

    Installation 12 installation voraussetzungen für den betrieb des kabelmodems müssen fol- gende bedingungen erfüllt sein: breitbandkabelanschluss mit rückkanal, netzwerkfähiger pc (ethernet 10/100base-t oder usb 1.1). Anschlüsse beim anschluss des kabelmodems gehen sie in folgender reihenfolge vor, s...

  • Page 13: Installation

    Installation 13 sprechend den anweisungen in der readme- datei auf der installations-cd vor. Bei problemen mit dem anschluss setzen sie sich bitte mit dem zuständigen kabelnetzbetreiber in verbindung. Verwenden sie zum festdrehen der f-stecker auf den f-buchsen keine werkzeuge. Ziehen sie die stecke...

  • Page 14

    Betriebsanzeigen und fehlerdiagnose 14 betriebsanzeigen und fehlerdiagnose zur statusüberwachung und fehlererkennung sind an der frontseite des kabelmodems fünf leds vorhanden: power leuchtet grün cable leuchtet grün pc blinkt oder leuchtet grün data blinkt oder leuchtet grün test dunkel (bei test o...

  • Page 15: Technische Daten

    Technische daten 15 technische daten das dcm 32 ist nach mcns docsis 1.0, 1.1, 2.0 und das dcm 42/42 i nach eurodocsis 1.0, 1.1, 2.0 spezifiziert. Downstream demodulation 64 qam / 256 qam eingangspegel -15 dbmv bis +15 dbmv eingangsimpedanz 75 Ω rückflussdämpfung >6 db von 88 mhz bis 860 mhz dcm 32 ...

  • Page 16: Technische Daten

    Technische daten 16 dcm 32 frequenzbereich 5 bis 42 mhz (eckfrequenzen) dcm 42 / 42 i frequenzbereich 5 bis 65 mhz (eckfrequenzen) snmp management mib group mib ii, mcns mib schnittstellen ethernet ieee802.3/10/100base-t usb usb 1.1 rf f-buchse 75 Ω betriebsspannung 12 v= leistungsaufnahme 9 w (max....

  • Page 17: Anschlussschema

    Anschlussschema 17 anschlussschema sehr geehrter kunde, sollten sie mit ihrem modem wider erwarten probleme haben, setzen sie sich bitte mit ihrem zuständigen kabelnetzbetreiber in verbindung. Usb-kabel ethernet- kabel kabelanschluss koaxkabel netz 10 b as e- t rf dc in us b.

  • Page 18: Preface

    Preface 18 preface dear customer, the new cable modems dcm 32 (docsis), dcm 42, and dcm 42 i (eurodocsis)* ) from kathrein provide you with high-speed access to the internet via the broadband cable connec- tion. While you now have an extremely fast connection to the internet at your disposal, your t...

  • Page 19: Connections and Displays

    Connections and displays 19 connections and displays leds (explanation on page 26) 1 2 3 4 1 power supply 12 v 2 rf input (f socket) 3 ethernet socket (western) 4 usb series b socket 10 bas e -t rf dc in us b.

  • Page 20: Safety Instructions

    Safety instructions 20 safety instructions important notes regarding operation the following section contains important informa- tion as to the operation, place of installation and connection of the receiver. Read these notes carefully before putting the unit into operation. Extended absence/thunder...

  • Page 21: Safety Instructions

    Safety instructions 21 repairs if repairs are needed, get a qualified specialist to carry them out and nobody else. Unauthorised opening and attempts at repairs entail loss of guarantee. Electrical safety can be put at risk by tampering with the unit. The manufacturer’s liability excludes accidents ...

  • Page 22: Putting Into Operation

    Putting into operation 22 putting into operation every electronic device generates heat. The rise in temperature, however, lies within a safe range. Slight colour changes may occur to sensitive fur- niture surfaces and veneers over the course of time due to the constant effect of heat. Colour change...

  • Page 23: Putting Into Operation

    Putting into operation 23 mains voltage run the modem via the accompanying plug-in power adapter off a mains voltage of 230 v/50 hz only. The unit must not be connected to the sup- ply until after the connections to the antenna socket and the pc have been set up. Grounding the house distribution sys...

  • Page 24: Installation

    Installation 24 installation preconditions for operation of the cable modem the following conditions need to be satisfied: broadband cable connection with backward channel, network-compatible pc (ethernet 10/100base-t or usb 1.1). Connections when connecting the cable modem, follow the steps below i...

  • Page 25: Installation

    Installation 25 provider if problems occur with the line. Do not use any tools to tighten the f-plugs on the f-sockets. Tighten the plug connectors hand-tight only! As soon as the modem is connected properly, it commences operation. No further measures are required. It now automatically finds the da...

  • Page 26

    Status indicators and error diagnosis 26 status indicators and error diagnosis there are five leds on the front panel of the ca- ble modem to monitor status and show errors: power lights up green cable lights up green pc flashes or lights up green data flashes or lights up green test not lit (orange...

  • Page 27: Specifications

    Specifications 27 specifications the dcm 32 corresponds to the specification mcns docsis 1.0,1.1, 2.0. The dcm 42 corre- sponds to the specification eurodocsis 1.0,1.1, 2.0. Downstream demodulation 64 qam / 256 qam input level -15 dbmv to +15 dbmv input impedance 75 Ω return loss >6 db from 88 mhz t...

  • Page 28: Specifications

    Specifications 28 dcm 32 frequency range 5 mhz to 42 mhz (edge frequencies) dcm 42 / 42 i frequency range 5 mhz to 65 mhz (edge frequencies) snmp management mib group mib ii, mcns mib interfaces ethernet ieee802.3/10base-t usb usb 1.1 rf f socket, 75 Ω voltage supply 12 vdc power consumption 9 w (ma...

  • Page 29: Connection Scheme

    Connection scheme 29 connection scheme dear customer, in the unlikely event that you should experience problems with your modem, please contact your relevant cable network provider. Usb cable ethernet cable cable connection coaxcable mains 10 b as e- t rf dc in us b.

  • Page 30: Avant Propos

    Avant propos 30 avant propos cher client, les nouveaux modems dcm 32 (docsis), dcm 42 et dcm 42 i (eurodocsis) *) de kathrein vous offrent un accès à vitesse élevée à l'internet via une connexion par câble large bande. Vous disposez ainsi d'une liaison extrêmement rapide à l'internet et votre ligne ...

  • Page 31: Branchements Et Affichages

    Branchements et affichages 31 branchements et affichages voyants (explication à partir de la page 35) 1 2 3 4 1 alimentation 12 v 2 prise hf (embase type f) 3 prise ethernet (western) 4 prise usb 10 bas e -t rf dc in us b.

  • Page 32: Consignes De Sécurité

    Consignes de sécurité 32 consignes de sécurité remarques importantes concernant l'utilisation vous trouverez dans le paragraphe suivant des remarques importantes sur l'utilisation, le lieu d'installation et le raccordement du modem. Lisez attentivement ces remarques avant de met- tre en service l'ap...

  • Page 33: Consignes De Sécurité

    Consignes de sécurité 33 réparation faites réparer votre modem uniquement par des techniciens qualifiés. Toute ouverture de l'appa- reil et toute tentative de le réparer de votre propre initiative entraînent la perte de la garantie. Des interventions non qualifiées sur l'appareil peuvent en comprome...

  • Page 34

    Lieu d'installation et montage 34 lieu d'installation et montage lieu d'installation tout appareil électronique produit de la chaleur. L'élévation de température reste cependant dans des limites non dangereuses. La surface de cer- tains meubles ou des placages sensibles peuvent changer légèrement de...

  • Page 35

    Lieu d'installation et montage 35 tension d'alimentation n'utilisez le modem qu'avec l'adaptateur secteur livré avec le modem et branché seulement à une tension secteur de 230 v / 50 hz. L'appareil doit être branché sur le secteur seulement après que les liaisons à la prise d'antenne et au pc ont ét...

  • Page 36: Installation

    Installation 36 installation conditions préalables pour le fonctionnement du modem, les conditions suivantes doivent être satisfaites : raccordement pour câble large bande avec canal de retour, pc avec adaptation pour réseau (ethernet 10/100base-t ou usb 1.1). Raccordements pour brancher le modem câ...

  • Page 37: Installation

    Installation 37 en cas de problèmes de raccordement, veuillez contacter l'exploitant responsable du réseau câ- blé. N'employez pas d'outils pour serrer les fiches f sur les prises ou embases f. Un serrage à la main de ces fiches est suffisant ! Dès que le modem est correctement branché, il se met en...

  • Page 38

    Affichages de service diagnostique d'erreur 38 affichages de service diagnostique d'erreur pour surveillance du statut et reconnaissance d’erreurs il y a cinq leds sur la surface frontale du modem câble: power resplendit en vert cable resplendit en vert pc clignote ou resplendit en vert data clignot...

  • Page 39

    Affichages de service diagnostique d'erreur 39.

  • Page 40: Caractéristiques Techniques

    Caractéristiques techniques 40 caractéristiques techniques le dcm 32 est spécifié selon mcns docsis 1.0, 1.1, 2.0 et le dcm 42 / 42 i selon euro- docsis 1.0, 1.1, 2.0. Downstream démodulation 64 qam / 256 qam niveau d'entrée -15 dbmv à +15 dbmv impédance d'entrée 75 Ω atténuation de ré- flexion >6 d...

  • Page 41: Caractéristiques Techniques

    Caractéristiques techniques 41 dcm 32 plage de fréquence 5 mhz à 42 mhz (fréquences limites) dcm 42 / 42 i plage de fréquence 5 mhz à 65 mhz (fréquences limites) gestion snmp groupe mib mib ii, mcns mib interfaces ethernet ieee802.3/10/100base-t usb usb 1.1 hf embase type f 75 Ω tension de service 1...

  • Page 42: Schéma Des Connexions

    Schéma des connexions 42 schéma des connexions cher client, si, contre toute attente, votre modem devait vous poser quelques problèmes, veuillez contacter l'exploitant du réseau câblé. Câble usb câble ethernet branchement au réseau câblé câble coaxial adaptateur secteur 10 b as e- t rf dc in us b.

  • Page 43: Notizen

    Notizen 43 notizen.

  • Page 44: Notizen

    Notizen 44.

  • Page 45

    Internet: http://www.Kathrein.De kathrein-werke kg • phone ++49 80 31 184-0 • fax ++49 8031 184-306 anton-kathrein-straße 1 – 3 • p.O. Box 10 04 44 · d-83004 rosenheim • germany 93 6.24 56/ c /0 605/zwt t echn ische Änd erungen v or behalte n. Subj ec t to alterations. So us rése rv e de mo dif ic a...