Kathrein HDZ 100 Installation Manual

Manual is about: Caravan roof gland, Protective casing for cable interfaces on the caravan roof for Kathrein rotary antenna systems type CAP series

Summary of HDZ 100

  • Page 1

    Installation manual caravan roof gland hdz 100 protective casing for cable interfaces on the caravan roof for kathrein rotary antenna systems type cap series.

  • Page 2: Contents

    2 contents ............................................................................................................................... 2 foreign language installation manuals/service ...................................................... 3 address of the service centre .............................

  • Page 3: Esc

    3 dear customer, chère cliente, cher client, gentile cliente, estimado cliente, gb you can obtain an english version of our installation instructions from our representatives in your country (http://www.Kathrein.De/include/kontakte_groups_eng.Cfm?Kontinent=1&gruppe=sat) or download one from our home...

  • Page 4: Hdz 100 Scope of Supply

    4 hdz 100 components/scope of supply • cover with two gaskets and four captive screws • sealing plug • bottom half of the casing with gasket and six plugs • three fastening screws hdz 100 scope of supply • protective casing for cable interfaces on the caravan roof for kathrein rotary antenna systems...

  • Page 5: Proper Use

    5 proper use the hdz 100 roof gland protects the cable connection point and the roof gland point when laying cables from cap systems on the caravan or mobile home roof. The gland seatings are designed for two cables (Ø 5 mm) and one cable (Ø 6.5-7 mm). Any use other than that specifi ed above will v...

  • Page 6

    6 safety instructions - important notes safety during installation work when carrying out installation work in locations where there is a risk of falling, take appropriate safety precautions, e.G. Use of a working platform. Make sure that the vehicle roof is suffi ciently strong and stable to carry ...

  • Page 7

    7 cables lay all cables such that nobody can tread on them or trip over them. When connecting the power cables (receiver and turntable) to the vehicle electrical supply, make sure that the cable polarity is not reversed. If the cable polarity is reversed there is a risk of thermal overload and damag...

  • Page 8: Installation Examples

    8 installation examples basic variants roof gland with cable interface roof gland without cable interface cable continuation with cable interface note: for the cap 600/700 units there are always two cables emerging from the turntable. For the cap 900 unit there are always three cables emerging from ...

  • Page 9: Installation And Connection

    9 • circular cutter, Ø 38 mm • cross-head screwdriver for m4 screws • power drill • twist drill Ø 2.5 mm • knife • round fi le or emery paper • sikafl ex ® 291 sealant (included in the cap turntable scope of supply. Comply with the respective safety instructions for the sealant) • if required for th...

  • Page 10: Installation And Connection

    10 installation and connection installation steps roof gland variant 1. In the centre of the intended position of the cable outlet spigot, drill the opening for the cable gland with a circular cutter (Ø: 38 mm). Deburr the hole with a round fi le or emery paper (see illustration on the right). 2. Pr...

  • Page 11: Installation And Connection

    11 installation and connection 5. Ensure before starting adhesive work that the temperature of materials to be glued and the adhesive sealant is between +5 °c and +40 °c. Prepare all necessary fastening elements and tools. 6. Prepare the tube of adhesive sealant in accordance with the instructions e...

  • Page 12: Installation And Connection

    12 cable continuation variant 1. First cut the cylindrical spigot off the underside of the casing. There are two ways of doing this: - use a sharp knife to cut through the wall between the base of the casing and the spigot (see illustration on the right) or 11. Use the plugs supplied to seal the cab...

  • Page 13: Installation And Connection

    13 9. Now open up the break-out in the end face of the cover for the cable outlet (see illustrations on the right). 2. Continue as described in points 3. To 8. Of the description for the “roof gland” variant. 10. Now connect the cables from the turntable on the cables from the interior of the vehicl...

  • Page 14: Installation And Connection

    14 installation and connection 11. Insert the cable in the seal and push it into the cable clips in the casing (see illustration on the right). 12. Use the plugs attached to seal the cable attachment points that are now not required (see illustration on the right). Do not cut away any plugs that are...

  • Page 15: Technical Data (In Mm)

    15 technical data (in mm) 211 38 37 ()65 28,5 90 max. 31 max. 17 20 (3x) 2,5 schnittstellen: schutzart nach en 60529: ip55 verpackung: bruttogewicht: 0,35 kg nettogewicht: 0,25 kg - dachbohrung: 38 - leitungsführungskanal: b =31, h =17 - kabel: 2x hf 5; 1x dc 6,5 - 7 - kernbohrung in unterkonstrukti...

  • Page 16: For Your Notes

    Internet: http://www.Kathrein.De kathrein-werke kg • anton-kathrein-straße 1 - 3 p.O. Box 100 444 • 83004 rosenheim germany 936.3442/-/0908/zwt - t echnical data subject to change. For your notes.