Keating Of Chicago 37399 User Manual - Avoid Service Checklist

Manual is about: GAS GRIDDLE

Summary of 37399

  • Page 1

    1-800-keating www.Keatingofchicago.Com users manual miraclean ® gas griddle series 2000 read and save this manual for future reference. Keep this manual for training new personnel. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 installation instruct...

  • Page 2

    Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. Warning improper installation can cause damage, injury or death. N...

  • Page 3: Introduction

    Introduction instructions in this manual should be read thoroughly before attempting to operate this miraclean ® griddle. All installation and service on keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel. Service information for...

  • Page 4

    Gas connections and pipe size the miraclean ® griddle requires a standard gas pipe size of 3/4 inch (19mm) i.D. Connection. The size of the gas supply pipe is very important if the pipe is too small you will have low gas pressure at the miraclean ® griddle manifold. Low gas pressure will cause slow ...

  • Page 5: Placing Miraclean

    Assembly instructions for griddle stand on casters (there is no top on this stand) placing miraclean ® griddle in operation (when all previous instructions have been completed). Check the serial plate to determine if the burner is set up for the proper type gas before connecting the quick- disconnec...

  • Page 6: Cooking With Your

    4 lighting instructions miraclean ® griddle (see lighting instructions plate attached to front of miraclean ® griddle). Make sure that the main gas valve on the gas supply line to the miraclean ® griddle is in the “on” position. 1. Turn gas valve knob to "pilot" position. 2. Push gas valve knob inwa...

  • Page 7: Cooking Procedures

    The miraclean ® griddle can be kept in perfect condition by using a razor blade griddle scraper to remove the film that is deposited from the products that have been previously cooked. Eggs, being cooked at a lower temperature, require substantially no scraping; but meat and meat products cooked at ...

  • Page 8: Cleaning The Miraclean®

    Cleaning the miraclean® griddle the surface of the miraclean ® griddle is very durable and with proper care, following the procedures below, will last many years. A sample of keating klenzer, keating palmetto brush and a 4" scraper are included with each new griddle. 1. Scrape miraclean ® surface. 2...

  • Page 9: Avoid Service Checklist

    Preventive maintenance cleaning chart avoid service checklist before calling for service, review this list. It may save you both time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Warranty repairs keating’s warrant...

  • Page 10: Parts List

    8 figure 6-3 natural and propane gas heating systems item description part number 1 spark ignition assembly see item 4, figure 6-2 2 thermopile 022770 3 pilot tube (1/4”) 007998 4 pilot assembly 029769 (all natural gas, 24”-30” 029599 lp, 24”-39” bef) natural gas orifice 007696 propane orifice 00776...

  • Page 11: Service Diagnosis

    9 service diagnosis the following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qualified & licensed service company. (equipment still under warranty requires it.) note: to correctly and quickly diagnose the system, the chart below should b...

  • Page 12: Service

    Service servicing should only be performed by qualified & licensed service companies. Gas valve regulator adjustment recommended gas pressure at manifold (4.0" w.C. Natural gas 10.0" w.C. Propane gas) adjustment of the gas valve pressure regulator is not normally necessary since it has been preset a...

  • Page 13

    Millivolt check (for qualified service technicians only) the millivolt valve is a thermopile self-powered combination gas control. Before checking the millivolt system, the following operations should be performed and observations made: 1. A genuine keating millivolt thermostat should be used for mi...

  • Page 14

    B. Thermopile output check (“b” reading. Thermostat contacts open - main burner off.) 1. Thermopile system - 500 millivolts minimum. If the minimum millivolt reading is not obtainable, readjust thermopile for maximum millivolt output. If millivolt reading is still below minimum specified, replace th...

  • Page 15

    13 gas griddle wiring diagram control panel thermostat on/off switch.

  • Page 16: Arranty

    L imited w arranty keating of chicago, inc. ("keating”) warrants to the original purchaser . ("customer"), all new keating fryers, filter systems, griddles, keep krisp®, custom pasta systems, t op-side™ cookers, computer t imers, fryer & pasta v essels, and keating replacement parts ("pro ducts") in...

  • Page 17

    15 service information if you have a service related question call 1-800-keating. Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. Keating of chicago, inc. 8901 w. 50th street, mccook, illinois ...