KEB COMBIVERT F4-C Applications Manual

Summary of COMBIVERT F4-C

  • Page 1

    Antriebstechnik stand 02/2001 combivert f4-c application manual art.Nr.: 0c.F4.0ea-k220 charge 75,-dm.

  • Page 2: Introduction

    1 1 name:basis keb combivert f4-c 2 05.01.99 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 3: Introduction

    3 antriebstechnik 1 1 3 05.01.99 keb combivert f4-c name:basis 1 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date this chapter shall allow a fast access to the wanted information. It consists of contents, index and search criterion. Here the inverter and...

  • Page 4: Introduction

    1 1 name: basis keb combivert f4-c 4 05.01.99 introduction © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 5: Introduction

    5 antriebstechnik 1 1 5 05.01.99 keb combivert f4-c name: basis 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 1.1 general introduction © keb antriebstechn...

  • Page 6: Introduction

    1 1 name:basis keb combivert f4-c 6 05.01.99 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 7: Introduction

    7 antriebstechnik 1 1 7 05.01.99 keb combivert f4-c name:basis 1 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date 1.1 general 1. Introduction 1.1.1 table of contents 1. Introduction ...........................................................................

  • Page 8: Introduction

    1 1 name:basis keb combivert f4-c 8 05.01.99 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date 4.3 cp-parameter ..................................................................................... 4.3.3 4.3.1 operation in cp-mode ...........................

  • Page 9: Introduction

    9 antriebstechnik 1 1 9 05.01.99 keb combivert f4-c name:basis 1 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date 6.3 digital in- and outputs ...................................................................... 6.3.3 6.3.1 short description digital inp...

  • Page 10: Introduction

    1 1 name:basis keb combivert f4-c 10 05.01.99 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date 6.7 keep on running functions.............................................................. 6.7.3 6.7.1 ramp stop and hardware current limit .....................

  • Page 11: Introduction

    11 antriebstechnik 1 1 11 05.01.99 keb combivert f4-c name:basis 1 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date 6.12 cp-parameter definition .................................................................. 6.12.3 6.12.1 survey ........................

  • Page 12: Introduction

    1 1 name:basis keb combivert f4-c 12 05.01.99 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 13: Introduction

    13 antriebstechnik 1 1 13 05.01.99 keb combivert f4-c name:basis 1 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date who shall read all this? Everybody who is entrusted with the development and construction of applications. He who knows the extensive prog...

  • Page 14: Introduction

    1 1 name: basis keb combivert f4-c 14 05.01.99 introduction © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 15: Introduction

    15 antriebstechnik 1 1 15 05.01.99 keb combivert f4-c name:basis 1 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date * typ: (b)ase; (n)ew; chang(e); (a)ddition no. Typ *) date name description 1 b 01.02.1998 keb combivert f4-c - 2 e 10.11.1998 chapter 6.1...

  • Page 16: Introduction

    1 1 name:basis keb combivert f4-c 16 05.01.99 introduction general © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 17: Summary

    Antriebstechnik 2 1 1 keb combivert f4-c name: basis 09.04.99 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 2.1 product description © keb antriebstechnik,...

  • Page 18: Product Description

    2 1 keb combivert f4-c 2 name: basis 09.04.99 © keb antriebstechnik, 1999 all rights reserved product description summary chapter section page date.

  • Page 19: Product Description

    3 antriebstechnik 2 1 3 keb combivert f4-c name: basis 09.04.99 2 © keb antriebstechnik, 1999 all rights reserved product description summary section page date chapter = ~ = ~ u n r c w u v u zk l1 l2 (l3) m 3 ~ 2.1.1 features of keb combivert f4-c 2.1 product description keb combivert f4-c 8 parame...

  • Page 20: Product Description

    2 1 keb combivert f4-c 4 name: basis 09.04.99 © keb antriebstechnik, 1999 all rights reserved product description summary chapter section page date 2.1.3 application as directed the keb combivert is a frequency inverter with dc-voltage link. It works according to the principle of the pulse-width mod...

  • Page 21: Product Description

    5 antriebstechnik 2 1 5 keb combivert f4-c name: basis 09.04.99 2 © keb antriebstechnik, 1999 all rights reserved product description summary section page date chapter 2.1.4 type code 15.F4.C1g–3440 options 0 = standard clock frequency 1 = 2 khz 2 = 4 khz 4 = 8 khz 6 = 12 khz 8 = 16 khz supply volta...

  • Page 22: Product Description

    2 1 keb combivert f4-c 6 name: basis 09.04.99 © keb antriebstechnik, 1999 all rights reserved product description summary chapter section page date 2.1.6 unit sizes 230v-class the following technical specifications refer to 2-/4-pole standard motors. In case of different pole numbers the frequency i...

  • Page 23: Product Description

    7 antriebstechnik 2 1 7 keb combivert f4-c name: basis 09.04.99 2 © keb antriebstechnik, 1999 all rights reserved product description summary section page date chapter 2.1.7 unit sizes 400v-class (07-17) 1) from housing size m fuses of type ferra z 6,6 urd xxx must be used. 2) this data is only vali...

  • Page 24: Product Description

    2 1 keb combivert f4-c 8 name: basis 09.04.99 © keb antriebstechnik, 1999 all rights reserved product description summary chapter section page date unit sizes 400v-class (18-29) 1) from housing size m fuses of type ferra z 6,6 urd xxx must be used. 2) this data is only valid for units with internal ...

  • Page 25: Hardware

    Antriebstechnik 3 1 1 keb combivert f4-c name: basis 10.02.98 hardware chapter section page date © keb antriebstechnik, 1997 all rights reserved 3.1 control units 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Pr...

  • Page 26: Hardware

    3 1 keb combivert f4-c 2 name: basis 09.02.98 chapter section page date © keb antriebsteclnik, 1997 all rights reserved hardware control cards.

  • Page 27: Hardware

    3 3 3 3 3 antriebstechnik 3 1 3 keb combivert f4-c name: basis 09.02.98 3 section page date © keb antriebstechnik, 1997 all rights reserved chapter hardware control cards 3.1.1 survey 3.1 control units depending on the functional extent and the housing size 3 variants of f4c-control cards are availa...

  • Page 28: Hardware

    3 1 keb combivert f4-c 4 name: basis 09.02.98 chapter section page date © keb antriebsteclnik, 1997 all rights reserved hardware control cards 3.1.2 control cards 0a.F4.080-xxxx this control card is used in d and e units when no speed detection is required. The following changes in the parameter and...

  • Page 29: Hardware

    5 5 5 5 5 antriebstechnik 3 1 5 keb combivert f4-c name: basis 09.02.98 3 section page date © keb antriebstechnik, 1997 all rights reserved chapter hardware control cards 3.1.3 control card 0d.F4.080-xxxx this control card is used in d and e units when a speed detection is required. According to the...

  • Page 30: Hardware

    3 1 keb combivert f4-c 6 name: basis 09.02.98 chapter section page date © keb antriebsteclnik, 1997 all rights reserved hardware control cards 20 22 23 1 2 3 4 21 16 17 18 5 6 7 8 9 10 11 12 13 14 15 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 3.1.5 control terminal strip for hous...

  • Page 31: Hardware

    7 7 7 7 7 antriebstechnik 3 1 7 keb combivert f4-c name: basis 09.02.98 3 section page date © keb antriebstechnik, 1997 all rights reserved chapter hardware control cards 4 5 6 7 10 11 13 14 19 20 + pe 4 5 6 7 10 11 13 14 19 20 pe 4 5 6 7 10 11 13 14 19 20 + pe 8 9 + - pe 18 *1 8 9 16 17 18 pe 16 17...

  • Page 32: Hardware

    3 1 keb combivert f4-c 8 name: basis 09.02.98 chapter section page date © keb antriebsteclnik, 1997 all rights reserved hardware control cards 1 2 3 12 21 22 23 14 13 +15....18v 15 18 + pe + 30v dc / 1 a 30v dc / 1 a out 1 out 2 out 3 3.1.8 wiring of out- puts at transistor output x1.12 a current of...

  • Page 33: Fundamentals

    Antriebstechnik 4 1 1 keb combivert f4-c name: basis 09.02.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 4.1 fundamentals 4.2 password structure 4.3 cp...

  • Page 34: Operation

    4 1 keb combivert f4-c 2 name: basis 09.02.98 operation fundamentals © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 35: Operation

    Antriebstechnik keb combivert f4-c name: basis 4 1 3 09.02.98 4 operation fundamentals © keb antriebstechnik, 1997 all rights reserved section page date chapter 4.1.1 parameters, parameter groups, parameter sets 4.1 fundamentals the following chapter describes the fundumentals of the software struct...

  • Page 36: Operation

    4 1 keb combivert f4-c 4 name: basis 09.02.98 operation fundamentals © keb antriebstechnik, 1997 all rights reserved chapter section page date 4.1.2 selection of a parameter the blinking point indicates the changeable area. By pressing the enter-key the blinking point is shifted. ✻ enter f/r enter f...

  • Page 37: Operation

    Antriebstechnik keb combivert f4-c name: basis 4 1 5 09.02.98 4 operation fundamentals © keb antriebstechnik, 1997 all rights reserved section page date chapter 4.1.5 non- programmable parameters certain parameters are not programmable, as their value must be the same in all sets (e.G. Bus address o...

  • Page 38: Operation

    4 1 keb combivert f4-c 6 name: basis 09.02.98 operation fundamentals © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 39: Operation

    Antriebstechnik 4 2 1 keb combivert f4-c name: basis 09.02.98 operation 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex © keb antriebstechnik, 1997 all righ...

  • Page 40: Operation

    4 2 keb combivert f4-c 2 name: basis 09.02.98 © keb antriebstechnik, 1997 all rights reserved operation password structure chapter section page date.

  • Page 41: Password Structure

    3 antriebstechnik 4 2 3 keb combivert f4-c name: basis 09.02.98 4 password structure © keb antriebstechnik, 1997 all rights reserved operation section page date chapter 4.2 password structure the keb combivert is provided with extensive password protection. The different passwords are used to - chan...

  • Page 42: Operation

    4 2 keb combivert f4-c 4 name: basis 09.02.98 © keb antriebstechnik, 1997 all rights reserved operation password structure chapter section page date 4.2.2 passwords 4.2.3 changing of password level by selecting one of the following passwords you can switch to the respective password level: passwords...

  • Page 43: Operation

    Antriebstechnik 4 3 1 keb combivert f4-c name: basis 20.03.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 4.1 fundamentals 4.2 password structure 4.3 cp...

  • Page 44: Cp - Parameter

    4 3 keb combivert f4-c 2 name: basis 20.03.98 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date.

  • Page 45: Cp - Parameter

    3 antriebstechnik 4 3 3 keb combivert f4-c name: basis 20.03.98 4 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date 4.3.1 operation in cp-mode 4.3 cp-parameter the customer-parameters (cp) are a special group of parameter. With the exception of cp.0 (...

  • Page 46: Cp - Parameter

    4 3 keb combivert f4-c 4 name: basis 20.03.98 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date enabling of cp-parameter preadjusted cp-parameters are described in the following section. On delivery all cp-parameters are without password protection, i...

  • Page 47: Cp - Parameter

    5 antriebstechnik 4 3 5 keb combivert f4-c name: basis 20.03.98 4 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date display of actual inverter load in percent. 100% load correspond to the rated inverter current. Only positive values are displayed, i.E...

  • Page 48: Cp - Parameter

    4 3 keb combivert f4-c 6 name: basis 20.03.98 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date deceleration time fixed frequency 1...3 the parameter defines the time necessary to decelerate from 100 to o hz. The real deceleration time is proportional...

  • Page 49: Cp - Parameter

    7 antriebstechnik 4 3 7 keb combivert f4-c name: basis 20.03.98 4 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date 4.3.6 special settings the following parameters serve for the optimization of the drive and the adaption to the application. These sett...

  • Page 50: Cp - Parameter

    4 3 keb combivert f4-c 8 name: basis 20.03.98 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date speed search when connecting the frequency inverter to a coasting motor, an error may be triggered as a result of the different rotary field frequencies. A...

  • Page 51: Cp - Parameter

    9 antriebstechnik 4 3 9 keb combivert f4-c name: basis 20.03.98 4 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date slip compensation autoboost slip compensation compensates the speed changes caused by load changes. To activate the function, adjust a ...

  • Page 52: Cp - Parameter

    4 3 keb combivert f4-c 10 name: basis 20.03.98 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date dc-braking dc-braking time f t f ist cp.21 100 hz t bist at dc-braking the motor is not decelerated by the ramp. The fast stopping is done by a dc-voltage...

  • Page 53: Cp - Parameter

    11 antriebstechnik 4 3 11 keb combivert f4-c name: basis 20.03.98 4 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date relay output the relay output (terminal x1.1…x1.3) is factory adjusted as fault relay. With this parameter the function of the output...

  • Page 54: Cp - Parameter

    4 3 keb combivert f4-c 12 name: basis 20.03.98 cp - parameter © keb antriebstechnik, 1997 all rights reserved operation chapter section page date cp.10 cp. 9 u ref f 0 v 0 ma 4 ma 10 v 20 ma 20 ma setpoint signal the setpoint input ref (terminal x1.17) can be triggered with different signal levels. ...

  • Page 55: Operation

    Antriebstechnik 4 4 1 keb combivert f4-c name: basis 09.02.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 4.1 fundamentals 4.2 password structure 4.3 cp...

  • Page 56: Operation

    4 4 keb combivert f4-c 2 name: basis 09.02.98 operation drive-mode © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 57: Operation

    3 antriebstechnik 4 4 3 keb combivert f4-c name: basis 09.02.98 4 operation drive-mode © keb antriebstechnik, 1997 all rights reserved section page date chapter start stop func. Speed enter f/r the drive-mode is a special operating mode of the keb combivert. It allows an easy manual start-up. To act...

  • Page 58: Operation

    4 4 keb combivert f4-c 4 name: basis 09.02.98 operation drive-mode © keb antriebstechnik, 1997 all rights reserved chapter section page date 4.4.4 rotation setting setting possibilities: f = forward (clockwise rotation) r = reverse (counter-clockwise rotation) each actuatin of the key enter causes a...

  • Page 59: Operation

    5 antriebstechnik 4 4 5 keb combivert f4-c name: basis 09.02.98 4 operation drive-mode © keb antriebstechnik, 1997 all rights reserved section page date chapter to leave the drive-mode, the keys „func“ and „enter“ must be pressed simultaneously for approx. 3 seconds while being in status „stop“! The...

  • Page 60: Operation

    4 4 keb combivert f4-c 6 name: basis 09.02.98 operation drive-mode © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 61: Parameter

    Antriebstechnik 5 1 1 keb combivert f4-c name: basis 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 5.1 parameter parameter chapter section page date © keb...

  • Page 62: Parameter

    5 1 keb combivert f4-c 2 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved 20.03.98 parameter.

  • Page 63: Parameter

    3 antriebstechnik 5 1 3 keb combivert f4-c name: basis 5 section page date © keb antriebstechnik, 1997 all rights reserved chapter 20.03.98 parameter picture 5.1.1 5.1.1 parameter groups 5.1 parameter the frequency inverter keb combivert f4-c contains 14 fixed and one free-to- define parameter group...

  • Page 64: Parameter

    5 1 keb combivert f4-c 4 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved 20.03.98 parameter preparatory measures.

  • Page 65: Parameter

    5 antriebstechnik 5 1 5 keb combivert f4-c name: basis 5 section page date © keb antriebstechnik, 1997 all rights reserved chapter 20.03.98 parameter 5.1.2 parameter listing f4-c pr - parameter addr. Min max default [?] see page(s) pr 4 pole number 012a - - √ 2 12 2 4 - 11.2.4 pr 5 malfunction code ...

  • Page 66: Parameter

    5 1 keb combivert f4-c 6 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved 20.03.98 parameter op 29 motorpoti inc./dec. Time 211d - - √ 0,00 300,00 0,01 131,00 sec 6.9.14 op 30 motorpoti prescaler 211e - √ √ 0 8 1 0 - 6.9.14 op 31 motorpoti destination 211f - √ √ ...

  • Page 67: Parameter

    7 antriebstechnik 5 1 7 keb combivert f4-c name: basis 5 section page date © keb antriebstechnik, 1997 all rights reserved chapter 20.03.98 parameter cn 14 ext. Pi delta ref max. 250e √ - √ 0,0 100,0 0,1 100,0 % 6.11.7; 6.11.8 cn 15 ext. Pi ref absolut 250f √ - √ -100,0 100,0 0,1 0,0 % 6.11.7 cn 16 ...

  • Page 68: Parameter

    5 1 keb combivert f4-c 8 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved 20.03.98 parameter fr 5 parameter set activation delay 2705 √ - √ 0 2,55 0,01 0 sec 6.8.7 fr 6 parameter set deactivation delay 2706 √ - √ 0 2,55 0,01 0 sec 6.8.7 fr 9 bus parameter set 270...

  • Page 69: Parameter

    9 antriebstechnik 5 1 9 keb combivert f4-c name: basis 5 section page date © keb antriebstechnik, 1997 all rights reserved chapter 20.03.98 parameter le 34 oh warning level 2b22 √ - √ 0 100 1 70 degrees le 35 timer value 2b23 √ - √ 0,00 100,00 0,01 0,00 sec 6.3.11; 6.9.17 le 36 frequency hysteresis ...

  • Page 70: Parameter

    5 1 keb combivert f4-c 10 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved 20.03.98 parameter.

  • Page 71: Functional Description

    Antriebstechnik 6 1 1 09.04.99 name: basis keb combivert f4-c functional description © keb antriebstechnik, 1999 all rights reserved 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12...

  • Page 72: Functional Description

    6 1 name: basis keb combivert f4-c 2 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays.

  • Page 73: Functional Description

    3 antriebstechnik 6 1 3 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays 6.1.1 summary of ru-parameters 6.1 operating and appliance displays 6.1.2 summary of in-parameters ru. 0...

  • Page 74: Functional Description

    6 1 name: basis keb combivert f4-c 4 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default 6.1.3 explanation to parameter description for a better survey the parameters, described in the followi...

  • Page 75: Functional Description

    5 antriebstechnik 6 1 5 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default the inverter status shows the current operating status of the inverter (e.G. Forwar...

  • Page 76: Functional Description

    6 1 name: basis keb combivert f4-c 6 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays display bus value ru.0 meaning error code pr.5 31 error external fault (external error ); is triggered, when a digital input...

  • Page 77: Functional Description

    7 antriebstechnik 6 1 7 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays display bus value ru.0 meaning error code pr.5 75 dc-brake active; is displayed during the deceleration ...

  • Page 78: Functional Description

    6 1 name: basis keb combivert f4-c 8 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default adr. Min max default ud.11 !Ud.11! 2001h ru. 1 actual speed display 0,5 rpm - 1638...

  • Page 79: Functional Description

    9 antriebstechnik 6 1 9 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default adr. Min max default adr. Min max default adr. Min max default...

  • Page 80: Functional Description

    6 1 name: basis keb combivert f4-c 10 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default adr. Min max default adr. Min max default 200bh ru.11 dc-link voltage 1 v - 999 2...

  • Page 81: Functional Description

    11 antriebstechnik 6 1 11 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default 200fh ru.15 output terminal status 1 - - 255 0 display of th...

  • Page 82: Functional Description

    6 1 name: basis keb combivert f4-c 12 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default adr. Min max default adr. Min max default 2011h ru.17 internal output status 1 - ...

  • Page 83: Functional Description

    13 antriebstechnik 6 1 13 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default adr. Min max default adr. Min max default adr. Min max defau...

  • Page 84: Functional Description

    6 1 name: basis keb combivert f4-c 14 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default adr. Min max default adr. Min max default adr. Min max default 2021h ru.33 displa...

  • Page 85: Functional Description

    15 antriebstechnik 6 1 15 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default adr. Min max default ud.11 !Ud.11! Ud.11 !Ud.11! 202dh ru.45...

  • Page 86: Functional Description

    6 1 name: basis keb combivert f4-c 16 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default adr. Min max default 2c01h 0,1 a ltk 460 0 6.1.5 description of in-parameters 2c00h in. 0 inverter typ...

  • Page 87: Functional Description

    17 antriebstechnik 6 1 17 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default 2c02h 0,0125 hz 409,5875 409,5875 0 adr. Min max default 2c03h adr. Min max defau...

  • Page 88: Functional Description

    6 1 name: basis keb combivert f4-c 18 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default 1 - 0 65535 0 adr. Min max default 1 - s.O. 32767 -32767 (0) adr. Min max default 2c28h 1 - - 63 0 s.A...

  • Page 89: Functional Description

    19 antriebstechnik 6 1 19 09.04.99 keb combivert f4-c name: basis 6 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays adr. Min max default 1 - 0 255 0 adr. Min max default 2c3ah adr. Min max default 2c3bh 1 - 0 32767 0 1...

  • Page 90: Functional Description

    6 1 name: basis keb combivert f4-c 20 09.04.99 © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date operating and appliance displays.

  • Page 91: Functional Description

    Antriebstechnik 6 2 1 keb combivert f4-c name: basis 27.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved 6.1 operating and appliance displays 6.2 analog in- and outputs 6.3 digital in- and outputs 6.4 set value and ramp adjustment 6.5 voltage/frequency (u/f) characteri...

  • Page 92: Functional Description

    6 2 keb combivert f4-c 2 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved 27.01.98 functional description analog in- and outputs.

  • Page 93: Functional Description

    3 antriebstechnik 6 2 3 keb combivert f4-c name: basis 6 27.01.98 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description analog in- and outputs 6.2.1 short description analog inputs 6.2 analog in- and outputs ru.22 ru.23 ru.45 an.12 an.8 an.2 an.27 an.3 an.4...

  • Page 94: Functional Description

    6 2 keb combivert f4-c 4 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved 27.01.98 functional description analog in- and outputs x1.8 ref+ x1.9 ref- + - x1.18 agnd x1.8 ref+ x1.9 ref- + - x1.8 ref+ x1.9 ref- x1.16 crf x1.18 agnd ri = 56k Ω Ω Ω Ω Ω ri = 40k Ω Ω Ω ...

  • Page 95: Functional Description

    5 antriebstechnik 6 2 5 keb combivert f4-c name: basis 6 16.02.00 section page date © keb antriebstechnik, 1999 all rights reserved chapter functional description analog in- and outputs 6.2.4 buffer memory (an.22) in order to control various inverters with different frequencies via the analog output...

  • Page 96: Functional Description

    6 2 keb combivert f4-c 6 name: basis chapter section page date © keb antriebstechnik, 1999 all rights reserved 16.02.00 functional description analog in- and outputs 100% 100% -100% -100% 100% 100% -100% -100% an.10 50% 100% 100% -100% -100% an.9 1. 2. An.11=100% 100% -100% an.10=75% an.9 6.2.5 inpu...

  • Page 97: Functional Description

    7 antriebstechnik 6 2 7 keb combivert f4-c name: basis 6 22.03.01 section page date © keb antriebstechnik, 1999 all rights reserved chapter functional description analog in- and outputs -10% 10% 10% -10% an.12 = 0 an.12 = 1 6.2.6 zero clamp speed (an.2 /an.8 / an.27) with capacitive and inductive in...

  • Page 98: Functional Description

    6 2 keb combivert f4-c 8 name: basis chapter section page date © keb antriebstechnik, 1999 all rights reserved 22.03.01 functional description analog in- and outputs an.14 an.15 an.16 an.17 x1.15 aout x1.18 agnd 0...±100% 0...10v ru.41 x1.18 agnd + - x1.15 aout u out =0...10v r b i max =5ma r i Ω 6....

  • Page 99: Functional Description

    9 antriebstechnik 6 2 9 keb combivert f4-c name: basis 6 27.01.98 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description analog in- and outputs 10v 100% -100% -100% an.15 an.16 an.17 100% 10v 100% -100% -100% an.16 an.17 100% an.15 10v 100% -100% -100% an.16...

  • Page 100: Functional Description

    6 2 keb combivert f4-c 10 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved 27.01.98 functional description analog in- and outputs param. Adr. Min max default enter prog. R/w step the analog output operates strictly under the in picture 6.2.10.A given values, the ...

  • Page 101: Functional Description

    Antriebstechnik 6 3 1 keb combivert f4-c name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved 6.1 operating and appliance displays 6.2 analog in- and outputs 6.3 digital in- and outputs 6.4 set value and ramp adjustment 6.5 voltage/frequency (u/f) characteri...

  • Page 102: Functional Description

    6 3 keb combivert f4-c 2 name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description digital in- and outputs.

  • Page 103: Functional Description

    3 antriebstechnik 6 3 3 keb combivert f4-c name: basis 28.01.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description digital in- and outputs 4 5 6 7 10 11 13 14 19 20 i1 i2 i3 i4 f r 0v u ext st rst pe x1 4 5 6 7 10 11 13 14 19 20 i1 i2 i3 i4 f r 0v u ex...

  • Page 104: Functional Description

    6 3 keb combivert f4-c 4 name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description digital in- and outputs 4 5 6 7 10 11 13 14 19 20 i1 i2 i3 i4 f r 0v u ext st rst pe x1 4 5 6 7 10 11 13 14 19 20 i1 i2 i3 i4 f r 0v u ext st rst pe x1 13......

  • Page 105: Functional Description

    5 antriebstechnik 6 3 5 keb combivert f4-c name: basis 28.01.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description digital in- and outputs as shown in picture 6.3.4it can be selected with parameter di.15 , if the inputs are switched by the terminal str...

  • Page 106: Functional Description

    6 3 keb combivert f4-c 6 name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description digital in- and outputs 4ms 8ms 8ms t t 8ms 8ms t t input signal digital filter inverted signal input status by edge triggering 6.3.8 strobe- dependent input...

  • Page 107: Functional Description

    7 antriebstechnik 6 3 7 keb combivert f4-c name: basis 28.01.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description digital in- and outputs t t t t t 4ms t t t t 10 11 14 f r u ext x1 10 11 14 f r u ext x1 edge-active strobe or static strobe? Di.19 stro...

  • Page 108: Functional Description

    6 3 keb combivert f4-c 8 name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description digital in- and outputs 6.3.10 functional assignment (di.3...Di.10) with the following parameters, the programmable inputs i1...I4 and the internal inputs ia...

  • Page 109: Functional Description

    9 antriebstechnik 6 3 9 keb combivert f4-c name: basis 28.01.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description digital in- and outputs picture 6.3.13 principle of digital outputs 0 1 2 3 10 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 3...

  • Page 110: Functional Description

    6 3 keb combivert f4-c 10 name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description digital in- and outputs 1 2 3 rla rlb rlc x1 max. 30v / 1a dc out2 12 13 14 a out 0v u ext x1 out1 +15v / 100ma out3 21 22 23 fla flb flc x1 max. 30v / 1a d...

  • Page 111: Functional Description

    11 antriebstechnik 6 3 11 keb combivert f4-c name: basis 28.01.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description digital in- and outputs valuefunction 6 ptc-warning, at tripping of the motor-ptc connected to the terminals oh/oh. After expiration of...

  • Page 112: Functional Description

    6 3 keb combivert f4-c 12 name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description digital in- and outputs & >1 0 1 bit 0 & >1 0 1 bit 1 bit 7 1 out1 out2 1 bit 7 bit 0 bit 1 0 1 0 1 out d do.25 do.0 do.10 do.9 do.16 picture 6.3.16 inverti...

  • Page 113: Functional Description

    13 antriebstechnik 6 3 13 keb combivert f4-c name: basis 28.01.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description digital in- and outputs param. Adr. Min max default enter prog. R/w step terminal name function decimal value do.0, do.25 u. Ru.15 x1.1...

  • Page 114: Functional Description

    6 3 keb combivert f4-c 14 name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description digital in- and outputs param. Adr. Min max default enter prog. R/w step do.2 2a02h ✔ ✔ ✔ 0 35 1 2 - do.3 2a03h ✔ ✔ ✔ 0 35 1 20 - do.4 2a04h ✔ ✔ ✔ 0 35 1 0 ...

  • Page 115: Functional Description

    15 antriebstechnik 6 3 15 keb combivert f4-c name: basis 28.01.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description digital in- and outputs param. Adr. Min max default enter prog. R/w step le.27 2b1bh ✔ ✔ - 100 v ltk 1 v 250 v ltk: depend. On power ci...

  • Page 116: Functional Description

    6 3 keb combivert f4-c 16 name: basis 28.01.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description digital in- and outputs.

  • Page 117: Functional Description

    Antriebstechnik 6 4 1 keb combivert f4-c name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12...

  • Page 118: Functional Description

    6 4 keb combivert f4-c 2 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date.

  • Page 119: Functional Description

    3 antriebstechnik 6 4 3 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment section page date chapter 6.4.1 short description 6.4 set value and ramp adjustment picture 6.4.1 principle of set value and ramp adj...

  • Page 120: Functional Description

    6 4 keb combivert f4-c 4 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date 0 1 2 3 4 5 6 7 8 15 16 17 x + an.13 0 1 2 3 4 5 6 + x + x 9 10 11 12 13 14 18 19 20 21 22 23 24 25 26 f x 60 ppz a u x op.0 op...

  • Page 121: Functional Description

    5 antriebstechnik 6 4 5 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment section page date chapter the aux-function offers the possibility to change other set values (ref-internal, the absolute digital set ...

  • Page 122: Functional Description

    6 4 keb combivert f4-c 6 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date 100% 100% ref / ±ref selection of set value and rotation direction (op.0) set value sources: sources of direction of rotation: ...

  • Page 123: Functional Description

    7 antriebstechnik 6 4 7 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment section page date chapter the direction of rotation can be activated by assigning terminal „f“ (forward x1.10) or „r“ (reverse x1.11)...

  • Page 124: Functional Description

    6 4 keb combivert f4-c 8 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date op.0 set value direction of rotation 0 analog (±ref / ref) digital (op.3) 1 analog (±ref / ref) terminal strip 2 analog (±ref /...

  • Page 125: Functional Description

    9 antriebstechnik 6 4 9 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment section page date chapter +f [hz] -f [hz] 409,5875 op.6* 1 (op.4) op.4 op.8 op.5 op.9* 1 (op.8) op.7* 1 (op.5) +100 -100 -409,5875 ab...

  • Page 126: Functional Description

    6 4 keb combivert f4-c 10 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date (op. 5) -100% +100% (op. 8) +f [hz] -f [hz] (op. 7) the unit differentiates between two set value settings: - the percent set ...

  • Page 127: Functional Description

    11 antriebstechnik 6 4 11 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment section page date chapter op.4 op.5 op.6 (op.4) op.7 (op.5) 2 1 op.4 op.5 op.6 (op.4) op.7 (op.5) 1 3 2 f1 f2 f3 i2 i1 t absolute s...

  • Page 128: Functional Description

    6 4 keb combivert f4-c 12 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date ramp mode op.10 f [hz] 100 50 10 t [s] 5 f [hz] 100 50 10 t [s] constant ascent: if 0....100hz are driven in 10s, then 0....50...

  • Page 129: Functional Description

    13 antriebstechnik 6 4 13 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment section page date chapter 100 80 0 ∆ f 100 50 ∆ t op.11 ∆ f ∆ t op.12 ∆ t ∆ f ∆ f op.13 * 1 ∆ t op.14 * 1 +f [hz] -f [hz] direction...

  • Page 130: Functional Description

    6 4 keb combivert f4-c 14 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date op.11 t [s] op.15 op.15 op.12 op.16 op.16 op.17 op.13 op.17 op.18 op.14 op.18 70 70 0 for some applications it is an advantage...

  • Page 131: Functional Description

    15 antriebstechnik 6 4 15 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment section page date chapter f_soll f_ist t t_rampe t_rampe t_rampe t_rampe t_rampe at the ramp with constant time the acceleration an...

  • Page 132: Functional Description

    6 4 keb combivert f4-c 16 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date the different ramp functions can be adjusted separately for every frequency change (acceleration forward, deceleration forward...

  • Page 133: Functional Description

    17 antriebstechnik 6 4 17 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment section page date chapter calculations the frequency change per raster scan delta_f (step size delta_f) for the mode constant ascen...

  • Page 134: Functional Description

    6 4 keb combivert f4-c 18 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved functional description set value and ramp adjustment chapter section page date step param. Adr. Enter prog. R/w min max default ru.4 2004h - - - - - 0,5 rev/min - - ru.6 2006h - - - -409,5875hz 409,5875hz ...

  • Page 135: Functional Description

    Antriebstechnik 6 5 1 keb combivert f4-c name: basis 28.01.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 6.1 operating and appliance displays 6.2 analo...

  • Page 136: Functional Description

    6 5 keb combivert f4-c 2 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved adjustment u/f-characteristic functional description chapter section page date.

  • Page 137: Functional Description

    3 antriebstechnik 6 5 3 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all right reserved adjustment u/f-characteristic functional description section page date chapter ua fout uf.1 100% uf.0 uf.2 = 0,0...409,5875 hz; default = 0 hz uf.3 = 0,0...100 %; default = 0 % 6.5 voltag...

  • Page 138: Functional Description

    6 5 keb combivert f4-c 4 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved adjustment u/f-characteristic functional description chapter section page date 250 v cp.17 = 230 v 190 v cp.5 = 50 hz f u n /u a uf.8 = 230v uf.0 = 50hz ua t uf.1 100% uf.5 uf.4 uf.4 = 0,0...25,5 %; default...

  • Page 139: Functional Description

    5 antriebstechnik 6 5 5 keb combivert f4-c name: basis 28.01.98 6 © keb antriebstechnik, 1997 all right reserved adjustment u/f-characteristic functional description section page date chapter picture 6.5.5.C example: deceleration of a drive with high inertia load from 80 hz with uzk-compensation wit...

  • Page 140: Functional Description

    6 5 keb combivert f4-c 6 name: basis 28.01.98 © keb antriebstechnik, 1997 all rights reserved adjustment u/f-characteristic functional description chapter section page date param. Adr. Min max default enter prog. R/w step 6.5.7 operating frequency (uf.11) the operating frequency, with which the powe...

  • Page 141: Functional Description

    Antriebstechnik 6 6 1 keb combivert f4-c name: basis 28.01.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 6.1 operating and appliance displays 6.2 analo...

  • Page 142: Functional Description

    6 6 keb combivert f4-c 2 name: basis 28.01.98 functional description motor presetting © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 143: Functional Description

    3 antriebstechnik 6 6 3 keb combivert f4-c name: basis 28.01.98 6 functional description motor presetting © keb antriebstechnik, 1997 all rights reserved section page date chapter antriebstechnik keb antriebstechnik gmbh & co. Kg schneeberg made in germany -mot ip im w.Ki. °c kg hz v cos /y 1/min u ...

  • Page 144: Functional Description

    6 6 keb combivert f4-c 4 name: basis 28.01.98 functional description motor presetting © keb antriebstechnik, 1997 all rights reserved chapter section page date param. Adr. Min max default enter prog. R/w step ohm u v w pe 6.6.4 motor stator resistance (dr.5) 6.6.5 used parameters dr.1 2401h ✔ ✔ - 0 ...

  • Page 145: Functional Description

    Antriebstechnik 6 7 1 keb combivert f4-c name: basis 28.01.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 6.1 operating and appliance displays 6.2 analo...

  • Page 146: Keep On Running Functions

    6 7 keb combivert f4-c 2 name: basis 12.03.99 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description chapter section page date.

  • Page 147: Keep On Running Functions

    3 antriebstechnik 6 7 3 keb combivert f4-c name: basis 12.03.99 6 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description section page date chapter 6.7 keep on running functions picture 6.7.1.A survey of ramp stop functions 6.7.1 ramp stop and hardware curren...

  • Page 148: Keep On Running Functions

    6 7 keb combivert f4-c 4 name: basis 12.03.99 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description chapter section page date param. Adr. Min max default enter prog. R/w step a b c used parameters pn.4 2204h ✔ ✔ - 0 7 1 - bit-coded pn.5 2205h ✔ ✔ - 10 % 199...

  • Page 149: Keep On Running Functions

    5 antriebstechnik 6 7 5 keb combivert f4-c name: basis 12.03.99 6 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description section page date chapter 6.7.2 maximum constant current (stall- function) the stall-function protects the frequency inverter against swi...

  • Page 150: Keep On Running Functions

    6 7 keb combivert f4-c 6 name: basis 12.03.99 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description chapter section page date param. Adr. Min max default enter prog. R/w step pn.12 220ch ✔ ✔ - 0 8 1 - bit-coded pn.13 220dh ✔ ✔ - 10 % 199 % (200 = off) 1 % 2...

  • Page 151: Keep On Running Functions

    7 antriebstechnik 6 7 7 keb combivert f4-c name: basis 12.03.99 6 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description section page date chapter 6.7.3 automatic restart and speed search picture 6.7.3.A principle of speed search conditions for the start of ...

  • Page 152: Keep On Running Functions

    6 7 keb combivert f4-c 8 name: basis 12.03.99 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description chapter section page date param. Adr. Min max default enter prog. R/w step picture 6.7.3.B speed search with „smooth“ adjusted function actual speed motor sp...

  • Page 153: Keep On Running Functions

    9 antriebstechnik 6 7 9 keb combivert f4-c name: basis 21.04.99 6 keep on running functions © keb antriebstechnik, 1999 all rights reserved functional description section page date chapter ⇓ ⇓ ⇓ ⇓ ⇓ ⇓ 6.7.4 electronic motor protection the motor protective function protects the connected motor agains...

  • Page 154: Keep On Running Functions

    6 7 keb combivert f4-c 10 name: basis 21.04.99 keep on running functions © keb antriebstechnik, 1999 all rights reserved functional description chapter section page date 50 100 150 200 400 600 800 % 5 sec 30 sec 1 min 2 min 30 min 60 min 120 min 120 f = 0 hz oh oh oh oh oh oh param. Adr. Min max def...

  • Page 155: Keep On Running Functions

    11 antriebstechnik 6 7 11 keb combivert f4-c name: basis 12.03.99 6 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description section page date chapter 6.7.5 dead time compensation (uf.17) the dead time compensation optimizes the switch-off times of the power m...

  • Page 156: Keep On Running Functions

    6 7 keb combivert f4-c 12 name: basis 12.03.99 keep on running functions © keb antriebstechnik, 1997 all rights reserved functional description chapter section page date.

  • Page 157: Functional Description

    Antriebstechnik 6 8 1 keb combivert f4-c name: basis 29.01.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 6.1 operating and appliance display 6.2 analog...

  • Page 158: Functional Description

    6 8 keb combivert f4-c 2 name: basis 29.01.98 functional description parameter sets © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 159: Functional Description

    3 antriebstechnik 6 8 3 keb combivert f4-c name: basis 29.01.98 6 functional description parameter sets © keb antriebstechnik, 1997 all rights reserved chapter section page date 6.8 parameter sets 6.8.2 copying of para- meter sets (fr.0, fr.1, fr.9) the keb combivert has 8 parameter sets (0…7), i.E....

  • Page 160: Functional Description

    6 8 keb combivert f4-c 4 name: basis 29.01.98 functional description parameter sets © keb antriebstechnik, 1997 all rights reserved chapter section page date picture 6.8.3.A principle of parameter set selection error message „nco“ if error message „nco“ is displayed, it may have following reasons: r...

  • Page 161: Functional Description

    5 antriebstechnik 6 8 5 keb combivert f4-c name: basis 29.01.98 6 functional description parameter sets © keb antriebstechnik, 1997 all rights reserved chapter section page date as shown in picture 6.8.3, with fr.2 it is determined whether the parameter set selection is done via keyboard/bus (fr.4) ...

  • Page 162: Functional Description

    6 8 keb combivert f4-c 6 name: basis 29.01.98 functional description parameter sets © keb antriebstechnik, 1997 all rights reserved chapter section page date input-coded set selection id ib i4 i2 i1 set 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 2 0 2 0 0 3 0 0 3 0 4 0 0 0 4 5 0 0 0 0 5 5 0 3 0 0 3 5 0 3 0 1 1 p...

  • Page 163: Functional Description

    7 antriebstechnik 6 8 7 keb combivert f4-c name: basis 29.01.98 6 functional description parameter sets © keb antriebstechnik, 1997 all rights reserved chapter section page date param. Adr. Min max default enter prog. R/w step 1 2 3 4 5 6 6.8.6 used parameters fr.0 2700h ✔ ✔ ✔ -2 7 1 0 not via bus f...

  • Page 164: Functional Description

    6 8 keb combivert f4-c 8 name: basis 29.01.98 functional description parameter sets © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 165: Functional Description

    Antriebstechnik 6 9 1 keb combivert f4-c name: basis 29.01.98 functional description chapter section page date © keb antriebstechnik, 1997 all rights reserved 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Errror assistance 10. Proje...

  • Page 166: Functional Description

    6 9 keb combivert f4-c 2 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions.

  • Page 167: Functional Description

    3 antriebstechnik 6 9 3 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions 6.9 special functions fig. 6.9.1 principle of dc-brake 6.9.1 dc-brake at dc-braking the motor is not de...

  • Page 168: Functional Description

    6 9 keb combivert f4-c 4 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions param. Adr. Min max default enter prog. R/w step survey of the different braking modes used parameters pn.8 2208h ✔ ✔ - 0 9 1 7...

  • Page 169: Functional Description

    5 antriebstechnik 6 9 5 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions t f, u a u a 50 % u/f param. Adr. Min max default enter prog. R/w step 6.9.2 energy saving function wit...

  • Page 170: Functional Description

    6 9 keb combivert f4-c 6 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions.

  • Page 171: Functional Description

    7 antriebstechnik 6 9 7 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions generatoric operation fig. 6.9.3.A triggering of the power-off function 6.9.3 power-off function it is ...

  • Page 172: Functional Description

    6 9 keb combivert f4-c 8 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions power-off-mode (pn.33) pn.33 bit 7 6 5 4 3 2 1 0 function value 128 64 32 16 8 4 2 1 automtatic x x x x x x 0 0 0% (function of...

  • Page 173: Functional Description

    9 antriebstechnik 6 9 9 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions a b a b a b f,u f,u t t f,u t a: dc-lin voltage b: output frequency jump factor (pn.38) by means of the...

  • Page 174: Functional Description

    6 9 keb combivert f4-c 10 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions 199 at this setting the dc-link setpoint value is equal to the tripping level pn. 17. An immediate restart upon voltage recove...

  • Page 175: Functional Description

    11 antriebstechnik 6 9 11 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions fig. 6.9.3.E behaviour at voltage recovery behaviour at voltage recovery the following parameters inf...

  • Page 176: Functional Description

    6 9 keb combivert f4-c 12 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions param . Adr. Min max default enter prog. R/w step buffering of short-time power failures parameter setting remarks pn.17 199 (...

  • Page 177: Functional Description

    6 9 keb combivert f4-c 12 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions.

  • Page 178: Functional Description

    13 antriebstechnik 6 9 13 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions 6.9.4 motor potentiome- ter function this function simulates a mechanic motor potentiometer. Via two ...

  • Page 179: Functional Description

    6 9 keb combivert f4-c 14 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions define inputs at first 2 inputs must be defined with which the motor potentiometer can be increased or decreased. For that two...

  • Page 180: Functional Description

    15 antriebstechnik 6 9 15 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions param. Adr. Min max default enter prog. R/w step used parameters setpoint value and direction of rota...

  • Page 181: Functional Description

    6 9 keb combivert f4-c 16 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions.

  • Page 182: Functional Description

    17 antriebstechnik 6 9 17 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions 6.9.5 timer programming two timers are integrated in the inverter. One timer counts from an adjusted ...

  • Page 183: Functional Description

    6 9 keb combivert f4-c 18 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions param. Adr. Min max default enter prog. R/w step counter/level 1...4 (le.41...Le.44) the conditions, at which the counter is r...

  • Page 184: Functional Description

    19 antriebstechnik 6 9 19 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions f1>f2 m h = f1-f2 f1 f2 m h = 0 f1 f2 m h m h f=f1-f2 f=0 6.9.6 braking control for applications in t...

  • Page 185: Functional Description

    6 9 keb combivert f4-c 20 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions 6.9.6.C example: desired direction of rotation forward: negative holding frequency with this parameter the function is activat...

  • Page 186: Functional Description

    21 antriebstechnik 6 9 21 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions param. Adr. Min max default enter prog. R/w step release of direction of rotation in case of analog s...

  • Page 187: Functional Description

    6 9 keb combivert f4-c 22 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions.

  • Page 188: Functional Description

    23 antriebstechnik 6 9 23 keb combivert f4-c name: basis 29.01.98 6 antriebstechnik section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description special functions 6.9.7 unit conversion the keb combivert makes available a parameter which allows the user to represen...

  • Page 189: Functional Description

    6 9 keb combivert f4-c 24 name: basis 29.01.98 name: basis chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description special functions param. Adr. Min max default enter prog. R/w step ru.43 202bh - - - -32767 32767 1 - - ud.87 2657h ✔ - - 0 4 1 0 - ud.88 2658h ...

  • Page 190: Functional Description

    Antriebstechnik 6 10 1 keb combivert f4-c name: basis 19.11.98 keb combivert f4-c antriebstechnik functional description chapter section page date © keb antriebstechnik, 1997 all rights reserved 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special oper...

  • Page 191: Functional Description

    6 10 keb combivert f4-c 2 name: basis 19.11.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description encoder interface.

  • Page 192: Functional Description

    3 antriebstechnik 6 10 3 keb combivert f4-c name: basis 19.11.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description encoder interface star t sto p ent er f/r fun c. Spe ed star t sto p ent er f/r fun c. Spe ed è è 6.10 encoder interface 6.10.1 encoder ...

  • Page 193: Functional Description

    6 10 keb combivert f4-c 4 name: basis 19.11.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description encoder interface 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 rt 150r a+ b+ a- b- 6.10.2 encoder inter- face with 2nd encoder fig. 6.10.2.A increm...

  • Page 194: Functional Description

    5 antriebstechnik 6 10 5 keb combivert f4-c name: basis 19.11.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description encoder interface cut-off frequency fig. 6.10.2.D input signals of channel 1 and 2 the cut-off frequency of the incremental encoder inte...

  • Page 195: Functional Description

    6 10 keb combivert f4-c 6 name: basis 19.11.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description encoder interface 3 2 1 1 2 3 1 2 3 p1 1 2 3 6.10.3 encoder interface with tacho gene- rator evaluation fig. 6.10.3.A incremental encoder interface with tac...

  • Page 196: Functional Description

    7 antriebstechnik 6 10 7 keb combivert f4-c name: basis 19.11.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description encoder interface 1 2 3 0v u ext fig. 6.10.5.B block diagram of initiator input r i : 1.9 k Ω u in (max.): u ext t puls (min.): 25 µ s t...

  • Page 197: Functional Description

    6 10 keb combivert f4-c 8 name: basis 19.11.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description encoder interface 6.10.7 evaluation of incremental encoders the evaluation of the incremental encoders is supported by two signals set off by 90° and signal...

  • Page 198: Functional Description

    9 antriebstechnik 6 10 9 keb combivert f4-c name: basis 19.11.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description encoder interface tacho generators supply an analog signal which is proportional to the speed of the tacho generators. The direction of ...

  • Page 199: Functional Description

    6 10 keb combivert f4-c 10 name: basis 19.11.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description encoder interface the initiator evaluation consists mainly of a counter, which is increased at every edge of the input signal the speed can now be calculat...

  • Page 200: Functional Description

    11 antriebstechnik 6 10 11 keb combivert f4-c name: basis 19.11.98 6 section page date © keb antriebstechnik, 1997 all rights reserved chapter functional description encoder interface param. Adr. Min max default enter prog. R/w step 6.10.14 used parameters ru.1 2001h - - - -32767 u/min 32676 u/min 0...

  • Page 201: Functional Description

    6 10 keb combivert f4-c 12 name: basis 19.11.98 chapter section page date © keb antriebstechnik, 1997 all rights reserved functional description encoder interface.

  • Page 202: Functional Description

    Antriebstechnik 6 11 1 keb combivert f4-c name: basis 30.01.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 6.1 operating and appliance display 6.2 analo...

  • Page 203: Functional Description

    6 11 keb combivert f4-c 2 name: basis 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 204: Functional Description

    3 antriebstechnik 6 11 3 keb combivert f4-c name: basis 6 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date 6.11.1 the pi-controller 6.11 pi-controller picture 6.11.1 pi-controller the keb combivert is equipped with a universally ...

  • Page 205: Functional Description

    6 11 keb combivert f4-c 4 name: basis 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date with it the control action during the start can be increased linear or at the reset of the fade-in decreased linear. The time refers of 100% o...

  • Page 206: Functional Description

    5 antriebstechnik 6 11 5 keb combivert f4-c name: basis 6 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date set value actual value pi-control set value calculation [%] actual value calculation [%] encoder interface ru.47 hz % % hz...

  • Page 207: Functional Description

    6 11 keb combivert f4-c 6 name: basis 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date cn.0 bit 1 and 2 = „3“ set value actual value pi-controller speed detection f presetting + + f_out this setting requires the optional availabl...

  • Page 208: Functional Description

    7 antriebstechnik 6 11 7 keb combivert f4-c name: basis 6 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date 6.11.4 set value calculation % f_out ±ref_int ref_int off cn.12 add. Set valuet/source add. Set value / cn.13 function cn....

  • Page 209: Functional Description

    6 11 keb combivert f4-c 8 name: basis 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date 100% 0% cn.10 cn.11 cn.10 minimum frequency= 0,0...409,5875 hz cn.11 maximum frequency = 0,0...409,5875 hz the adding set value can be influen...

  • Page 210: Functional Description

    9 antriebstechnik 6 11 9 keb combivert f4-c name: basis 6 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date cn.22 actual value preset -100%...100% ±ref_int. Ref_int. Option_int. Pi-controller ru.10 current inverter utilization (to...

  • Page 211: Functional Description

    6 11 keb combivert f4-c 10 name: basis 30.01.98 functional description pi-controller © keb antriebstechnik, 1997 all rights reserved chapter section page date cn31digital diameter setting 0,0%...100,0 % ±ref_int. Ref_int. Option_int. Cn.30 source diameter correction 0 1 2 3 4 off 100 fpreset= framp ...

  • Page 212: Functional Description

    11 antriebstechnik 6 11 11 keb combivert f4-c name: basis 6 16.02.00 functional description pi-controller © keb antriebstechnik, 1999 all rights reserved chapter section page date pi-controller f_preset + + f_out cn.27 cn.27 op.33 op.32 picture 6.11.7 controller action and limiting 6.11.7 controller...

  • Page 213: Functional Description

    6 11 keb combivert f4-c 12 name: basis 16.02.00 functional description pi-controller © keb antriebstechnik, 1999 all rights reserved chapter section page date step param . Adr. Enter prog. R/w min max default ru.3 2003h - - - -409,5875hz 409,5875hz 0,0125hz - - ru.30 201eh - - - -100,0% 100,0% 0,1% ...

  • Page 214: Functional Description

    Antriebstechnik 6 12 1 keb combivert f4-c name: basis 30.01.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 6.1 operating and appliance displays 6.2 anal...

  • Page 215: Functional Description

    6 12 keb combivert f4-c 2 name: basis 30.01.98 functional description cp-parameter definition © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 216: Functional Description

    3 antriebstechnik 6 12 3 keb combivert f4-c name: basis 30.01.98 6 functional description cp-parameter definition © keb antriebstechnik, 1997 all rights reserved chapter section page date 6.12 cp-parameter definition 6.12.1 survey picture 6.12.1 definition structure once the development stage of a m...

  • Page 217: Functional Description

    6 12 keb combivert f4-c 4 name: basis 30.01.98 functional description cp-parameter definition © keb antriebstechnik, 1997 all rights reserved chapter section page date 6.12.2 assignment of cp-parameter the following list shows the assignment of the ud-parameters to the cp-parameters. The first param...

  • Page 218: Functional Description

    5 antriebstechnik 6 12 5 keb combivert f4-c name: basis 30.01.98 6 functional description cp-parameter definition © keb antriebstechnik, 1997 all rights reserved chapter section page date param. Adr. Min max default enter prog. R/w step 6.12.4 example for example, a user menu with following characte...

  • Page 219: Functional Description

    6 12 keb combivert f4-c 6 name: basis 30.01.98 functional description cp-parameter definition © keb antriebstechnik, 1997 all rights reserved chapter section page date param. Adr. Min max default enter prog. R/w step ud.17 2611h ✔ - - -1 (off) 7fff 1 2000 corresponds to ru.0 ud.18 2612h ✔ - - 0 8 1 ...

  • Page 220: Functional Description

    7 antriebstechnik 6 12 7 keb combivert f4-c name: basis 30.01.98 6 functional description cp-parameter definition © keb antriebstechnik, 1997 all rights reserved chapter section page date param. Adr. Min max default enter prog. R/w step ud.51 2633h ✔ - - -1 (off) 7fff 1 2502 corresponds to cn.2 ud.5...

  • Page 221: Functional Description

    6 12 keb combivert f4-c 8 name: basis 30.01.98 functional description cp-parameter definition © keb antriebstechnik, 1997 all rights reserved chapter section page date.

  • Page 222: Start-Up

    Antriebstechnik 7 1 1 keb combivert f4-c name: basis 02.02.98 © keb antriebstechnik, 1997 all rights reserved start-up 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications...

  • Page 223: Start-Up

    7 1 keb combivert f4-c 2 name: basis 30.01.98 © keb antriebstechnik, 1997 all rights reserved start-up chapter section page date.

  • Page 224: Start-Up

    3 antriebstechnik 7 1 3 keb combivert f4-c name: basis 30.01.98 7 © keb antriebstechnik, 1997 all rights reserved start-up section page date chapter po we r xxx xxx xxx xxx inp ut ou tpu t keb antr iebs tech nik karl e. B rinkm ann gm bh d-3 267 7 b arntr up mad e in ge rma ny vo lta ge cyc le xxx x...

  • Page 225: Start-Up

    7 1 keb combivert f4-c 4 name: basis 30.01.98 © keb antriebstechnik, 1997 all rights reserved start-up chapter section page date 7.1.3 checklist prior to start-up before switching on the inverter go through the following checklist. þ is the inverter firmly bolted in the control cabinet? þ is there e...

  • Page 226: Start-Up

    Antriebstechnik 7 2 1 keb combivert f4-c name: basis 09.03.98 start-up © keb antriebstechnik, 1997 all rights reserved 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications...

  • Page 227: Initial Start-Up

    7 2 keb combivert f4-c 2 name: basis 09.03.98 © keb antriebstechnik, 1997 all rights reserved initial start-up start-up chapter section page date.

  • Page 228: Initial Start-Up

    3 antriebstechnik 7 2 3 keb combivert f4-c name: basis 09.03.98 7 © keb antriebstechnik, 1997 all rights reserved initial start-up start-up section page date chapter 7.2.1 switching on of keb combivert 7.2 initial start-up after all preparatory measures have been carried out the keb combivert f4 can...

  • Page 229: Initial Start-Up

    7 2 keb combivert f4-c 4 name: basis 09.03.98 © keb antriebstechnik, 1997 all rights reserved initial start-up start-up chapter section page date 7.2.2 basic settings in the cp-mode after switch-on with factory setting the inverter is in the cp-mode. The preadjusted values can be used for 90 % of al...

  • Page 230: Initial Start-Up

    5 antriebstechnik 7 2 5 keb combivert f4-c name: basis 09.03.98 7 © keb antriebstechnik, 1997 all rights reserved initial start-up start-up section page date chapter 7.2.4 testing of drive for the drive to always allow a save controlling through the inverter, carry out the following test under the m...

  • Page 231: Initial Start-Up

    7 2 keb combivert f4-c 6 name: basis 09.03.98 © keb antriebstechnik, 1997 all rights reserved initial start-up start-up chapter section page date.

  • Page 232: Special Operation

    Antriebstechnik 8 1 1 keb combivert f4-c name: basis 31.03.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex is currently updated and will soon be availabl...

  • Page 233: Special Operation

    8 1 keb combivert f4-c 2 name: basis 31.03.98 special operation chapter section page date © keb antriebstechnik, 1997 all rights reserved 8. Special operation.

  • Page 234: Error Assistance

    Antriebstechnik 9 1 1 keb combivert f4-c name: basis 05.06.98 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 9.1 troubleshooting error assistance chapter s...

  • Page 235: Error Assistance

    9 1 keb combivert f4-c 2 name: basis 05.06.98 error assistance chapter section page date © keb antriebstechnik, 1997 all rights reserved.

  • Page 236: Error Assistance

    3 antriebstechnik 9 1 3 keb combivert f4-c name: basis 05.06.98 9 error assistance section page date © keb antriebstechnik, 1997 all rights reserved chapter 9.1 troubleshooting 9.1.1 general 9. Error assistance the following chapter shall help you to avoid errors as well as help you to determine and...

  • Page 237: Error Assistance

    9 1 keb combivert f4-c 4 name: basis 05.06.98 error assistance chapter section page date © keb antriebstechnik, 1997 all rights reserved occurs when a too large load is applied longer than the permissible time allows (see technical data). Causes: - mechanical fault or overload in the application - w...

  • Page 238: Error Assistance

    5 antriebstechnik 9 1 5 keb combivert f4-c name: basis 05.06.98 9 error assistance section page date © keb antriebstechnik, 1997 all rights reserved chapter this error may occur at activated brake control (see chapter 6.9.6.) if the load is below the minimum load level (pn.58) during start up. To in...

  • Page 239: Error Assistance

    9 1 keb combivert f4-c 6 name: basis 05.06.98 error assistance chapter section page date © keb antriebstechnik, 1997 all rights reserved.

  • Page 240: Project Planning

    Antriebstechnik 10 1 1 keb combivert f4-c name: basis 31.03.98 project planning chapter section page date © keb antriebstechnik, 1997 all rights reserved 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project pla...

  • Page 241: Project Planning

    10 1 keb combivert f4-c 2 name: basis 31.03.98 project planning chapter section page date © keb antriebstechnik, 1997 all rights reserved.

  • Page 242: Project Planning

    3 antriebstechnik 10 1 3 keb combivert f4-c name: basis 31.03.98 10 project planning section page date © keb antriebstechnik, 1997 all rights reserved chapter 30 150 100 f4 f4 keb combivert 10.1 general design 10. Project planning the following chapter shall assist you in the planning stage of appli...

  • Page 243: Project Planning

    10 1 keb combivert f4-c 4 name: basis 31.03.98 project planning chapter section page date © keb antriebstechnik, 1997 all rights reserved 10.1.2 design of braking resistors the combivert fitted with an external braking resistor or an external braking option is suitable for a limited 4-quadrant opera...

  • Page 244: Project Planning

    5 antriebstechnik 10 1 5 keb combivert f4-c name: basis 31.03.98 10 project planning section page date © keb antriebstechnik, 1997 all rights reserved chapter ( ) (j m + j l ) • (n 1 - n 2 ) t bmin = 9,55 • (k • m n + m l ) 1. Braking time without braking resistor 2. Braking torque (necessary) 4. Br...

  • Page 245: Project Planning

    10 1 keb combivert f4-c 6 name: basis 31.03.98 project planning chapter section page date © keb antriebstechnik, 1997 all rights reserved.

  • Page 246: Project Planning

    Antriebstechnik 10 2 1 keb combivert f4-c name: basis 31.03.98 project planning chapter section page date © keb antriebstechnik, 1997 all rights reserved 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project pla...

  • Page 247: Project Planning

    10 2 keb combivert f4-c 2 name: basis 31.03.98 project planning drive design chapter section page date © keb antriebstechnik, 1997 all rights reserved 10.2 drive design.

  • Page 248: Netzwerkbetrieb

    1 antriebstechnik 11 1 1 keb combivert f4-c name: basis netzwerkbetrieb 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex 11.1 network components 11.2 driveco...

  • Page 249: Networks

    11 1 2 name: basis keb combivert f4-c 26.01.98 chapter section © keb antriebstechnik, 1996 all rights reserved page date networks network hardware.

  • Page 250: Networks

    3 antriebstechnik 11 1 3 11 keb combivert f4-c name: basis 26.01.98 chapter section page date © keb antriebstechnik, 1996 allk rights reserved networks network hardware 5 2 4 3 1 9 8 7 6 11.1.1 available hardware 11.1 network components the keb combivert f4 can be easily integrated into different ne...

  • Page 251: Networks

    11 1 4 name: basis keb combivert f4-c 26.01.98 chapter section © keb antriebstechnik, 1996 all rights reserved page date networks network hardware.

  • Page 252: Networks

    5 antriebstechnik 11 1 5 11 lwl - bus name: option 13.02.01 chapter section page date © keb antriebstechnik, 2001 all rights reserved networks network hardware 11.1.3 optical fibre bus - noise-immune data transfer - simple connection - electrical isolation - high transfer rates - simple bus design c...

  • Page 253: Networks

    11 1 6 name: option 00.F4.Z1a-kb15 13.02.01 chapter section © keb antriebstechnik, 2001 all rights reserved page date networks network hardware a b 52 43 1 98 7 6 b a + - 15 ... 30 v dc 75 mm 22,5 mm 105 mm description optical fibre operator switch receiver transmitter transmitter- led receiving- le...

  • Page 254: Networks

    7 antriebstechnik 11 1 7 11 lwl - bus name: option 13.02.01 chapter section page date © keb antriebstechnik, 2001 all rights reserved networks network hardware start stop func. Speed enter f/r start stop func. Speed enter f/r start stop func. Speed enter f/r start stop func. Speed enter f/r 2 3 5 2 ...

  • Page 255: Networks

    11 1 8 name: option 00.F4.Z1a-kb15 13.02.01 chapter section © keb antriebstechnik, 2001 all rights reserved page date networks network hardware.

  • Page 256: Networks

    9 antriebstechnik 11 1 9 11 keb combivert f4-c name: basis 26.01.98 chapter section page date © keb antriebstechnik, 1996 allk rights reserved networks network hardware loop-busklemme phoenix contact loop in out + - + - loop in out + - + - loop in out + - + - interbus-loop- operator interbus-loop- o...

  • Page 257: Networks

    11 1 10 name: basis keb combivert f4-c 26.01.98 chapter section © keb antriebstechnik, 1996 all rights reserved page date networks network hardware ld1 a b s1 cn1 ld5 ld4 ld6 ld7 ld3 ld2 cn2 11.1.5 interbus host controller board (internal) the interbus host controller board is connected to the inter...

  • Page 258: Netzwerkbetrieb

    1 antriebstechnik 11 2 1 keb combivert f4-c name: basis netzwerkbetrieb 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applikations 13. Annex 11.1 network components 11.2 bus-/dr...

  • Page 259: Networks

    11 2 2 networks bus-/drivecom-parameter chapter section name:basis © keb antriebstechnik, 1996 all rights reserved page date 26.03.98 keb combivert f4-c.

  • Page 260: Bedienung

    3 antriebstechnik 11 2 3 bedienung 11 networks bus-/drivecom-parameter keb combivert f4-c chapter section page 26.03.98 date name:basis © keb antriebstechnik, 1996 all rights reserved 11.2.1 adjustment of inverter address (ud.6) 11.2.2 baud rate (ud.7) with ud.6 the address is adjusted under which t...

  • Page 261: Networks

    11 2 4 networks bus-/drivecom-parameter chapter section name:basis © keb antriebstechnik, 1996 all rights reserved page date 26.03.98 keb combivert f4-c adr. Min max default adr. Min max default adr. Min max default 11.2.4 drivecom drivecom e.V. Is a user group of leading manufacturer in the power t...

  • Page 262: Bedienung

    5 antriebstechnik 11 2 5 bedienung 11 networks bus-/drivecom-parameter keb combivert f4-c chapter section page 26.03.98 date name:basis © keb antriebstechnik, 1996 all rights reserved adr. Min max default adr. Min max default adr. Min max default adr. Min max default adr. Min max default adr. Min ma...

  • Page 263: Networks

    11 2 6 networks bus-/drivecom-parameter chapter section name:basis © keb antriebstechnik, 1996 all rights reserved page date 26.03.98 keb combivert f4-c adr. Min max default adr. Min max default adr. Min max default adr. Min max default adr. Min max default pr. 18 acceleration delta time 0112h 0 327...

  • Page 264: Bedienung

    7 antriebstechnik 11 2 7 bedienung 11 networks bus-/drivecom-parameter keb combivert f4-c chapter section page 26.03.98 date name:basis © keb antriebstechnik, 1996 all rights reserved adr. Min max default adr. Min max default adr. Min max default pr. 39 percent reference value 0127h 0 32767 1 1500 1...

  • Page 265: Networks

    11 2 8 networks bus-/drivecom-parameter chapter section name:basis © keb antriebstechnik, 1996 all rights reserved page date 26.03.98 keb combivert f4-c 11.2.7 status and control word with parameter ud.5 (=1,3,5 or 7) the keb combivert is put into the drivecom mode, in which it responds to the contr...

  • Page 266: Netzwerkbetrieb

    1 antriebstechnik 12 1 1 keb combivert f4-c name: basis netzwerkbetrieb 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. Networks 12. Applications 13. Annex here solved applications are filed w...

  • Page 267: Applications

    12 1 2 26.01.98 keb combivert f4-c name: basis applications chapter section © keb antriebstechnik, 1996 all rghts reserved page date 12. Applications.

  • Page 268: Annex

    Antriebstechnik 13 1 1 keb combivert f4-c name: basis 25.03.98 annex chapter section page date © keb antriebstechnik, 1997 all rights reserved 1. Introduction 2. Summary 3. Hardware 4. Operation 5. Parameter 6. Functions 7. Start-up 8. Special operation 9. Error assistance 10. Project planning 11. N...

  • Page 269: Annex

    13 1 keb combivert f4-c 2 name: basis 25.03.98 annex search and find chapter section page date © keb antriebstechnik, 1997 all rights reserved.

  • Page 270: Annex

    Antriebstechnik 13 1 3 keb combivert f4-c name: basis 25.03.98 13 annex search and find section page date © keb antriebstechnik, 1997 all rights reserved chapter 13.1 search and find 13.1.1 index 13. Annex symbols ±ref 6.2.3, 6.2.7, 6.4.3, 6.4.5 230v-class 2.1.6 400v-class 2.1.7, 2.1.8 a absolute ma...

  • Page 271: Annex

    13 1 keb combivert f4-c 4 name: basis 25.03.98 annex search and find chapter section page date © keb antriebstechnik, 1997 all rights reserved counter 6.3.11 selection 6.7.9 cp-parameter 4.3.3, 6.12.4 definition 6.12.3 crf 6.2.4 current counter content 6.9.18 customer mode 4.1.3 d dc brake 6.9.3 bra...

  • Page 272: Annex

    Antriebstechnik 13 1 5 keb combivert f4-c name: basis 25.03.98 13 annex search and find section page date © keb antriebstechnik, 1997 all rights reserved chapter input characteristics amplifier 6.2.6 coded set selection 6.8.6 signals 6.2.4, 6.3.3 status 6.3.8 installation and connection 7.1.3 interb...

  • Page 273: Annex

    13 1 keb combivert f4-c 6 name: basis 25.03.98 annex search and find chapter section page date © keb antriebstechnik, 1997 all rights reserved pn.19 6.9.10 pn.33 6.9.8 pn.34 6.9.9 pn.36 6.9.9 pn.38 6.9.8 pn.42 6.9.7, 6.9.9, 6.9.10 pn.43 6.9.10 pn.50 6.7.7 pn.52...58 6.9.19 pnp 3.1.7 poff 6.3.11 pole...

  • Page 274: Annex

    Antriebstechnik 13 1 7 keb combivert f4-c name: basis 25.03.98 13 annex search and find section page date © keb antriebstechnik, 1997 all rights reserved chapter ssf 4.3.8 stall 4.3.11, 6.1.6, 6.3.11, 13.1.11 function 6.7.5 start key 4.4.3 parameter 6.12.4 up 7.1.3 starting jump 6.9.8 status display...

  • Page 275: Annex

    13 1 keb combivert f4-c 8 name: basis 25.03.98 annex search and find chapter section page date © keb antriebstechnik, 1997 all rights reserved.

  • Page 276: Annex

    Antriebstechnik 13 1 9 keb combivert f4-c name: basis 25.03.98 13 annex search and find section page date © keb antriebstechnik, 1997 all rights reserved chapter 13.1.2 term definition analog/digital earth the combivert f4 has isolated digital inputs, i.E. The inputs are galvanically separated from ...

  • Page 277: Annex

    13 1 keb combivert f4-c 10 name: basis 25.03.98 annex search and find chapter section page date © keb antriebstechnik, 1997 all rights reserved.

  • Page 278: Annex

    Antriebstechnik 13 1 11 keb combivert f4-c name: basis 25.03.98 13 annex search and find section page date © keb antriebstechnik, 1997 all rights reserved chapter et tarek el sehelly import & export p.O. Box 83 et-mehalla el kobra tel.: 0020/40243839 fax: 0020/40235753 ra eurotrans s.R.L. Sarmiento ...

  • Page 279: Annex

    13 1 keb combivert f4-c 12 name: basis 25.03.98 annex search and find chapter section page date © keb antriebstechnik, 1997 all rights reserved new keb antriebstechnik gmbh & co. Kg federal lands wildbacher str. 5 08289 schneeberg tel.: 0 37 72 / 67-0 fax: 0 37 72 / 6 72 81 new ing. Büro schumer & p...

  • Page 280: Annex

    Antriebstechnik 13 1 13 keb combivert f4-c name: basis 25.03.98 13 annex search and find section page date © keb antriebstechnik, 1997 all rights reserved chapter 13.1.5 notes.

  • Page 281: Annex

    13 1 keb combivert f4-c 14 name: basis 25.03.98 annex search and find chapter section page date © keb antriebstechnik, 1997 all rights reserved.

  • Page 282: Annex

    Antriebstechnik 13 1 15 keb combivert f4-c name: basis 25.03.98 13 annex search and find section page date © keb antriebstechnik, 1997 all rights reserved chapter.

  • Page 283

    © keb 0c.F4.0da-k220 01/99 antriebstechnik karl e. Brinkmann gmbh försterweg 36 - 38 • d - 32683 barntrup telefon 0 52 63 / 4 01 - 0 • telefax 4 01 - 116 internet: www.Keb.De • e-mail: info@keb.De.