    Installation manual spirit document id: sup-rim-eng date of issue: october 22, 2014 revision date: may 31, 2016.

  • Page 2

    Contents spirit installation manual page 1 installation quickstart ........................................................................................................................... 2 1. Connect water .............................................................................................

  • Page 3

    Installation quickstart spirit installation manual page 2 installation quickstart if the information in this section is not sufficient , we refer to the “installation manual” which you can find in a following section (page 14 onwards) of this manual, or contact your local installation technician. 1....

  • Page 4

    Installation quickstart spirit installation manual page 3 standard spirit has markings c and s: c= coffee boilers s= steam boiler spirit with individual pump per boiler has markings: l, (c,) r and s: l = left coffee boiler c = centre coffee boiler (triplette only) r= right coffee boiler s = steam bo...

  • Page 5

    Installation quickstart spirit installation manual page 4 4. Make sure that machine is switched “off” mains switch = “off” and … all temperature controller switches point down. 5. Connect electricity connect coffee pump cable(s) to coffee pump(s) and steam boiler pump cable to steam boiler pump. Dou...

  • Page 6

    Installation quickstart spirit installation manual page 5 3-phase 1- phase usa live l1 brown black l2 black brown l3 grey neutral n blue blue white* earth p e yellow/ green yellow/ green green mount cable directly in wall connection box or attach plug to mains power cable and plug in wall socket. Sh...

  • Page 7

    Welcome spirit installation manual page 6 welcome parts identification figure 1. Showing main operational parts of the spirit duette bastone version. The spirit triplette is wider since it has three groups but its functions are identical to the duette. On the touchpad version, the group brewing leve...

  • Page 8

    Welcome spirit installation manual page 7 note on this manual work on the spirit manual started in march 2012 and is a continuing process. Photographs in the manual are taken in the shop from (pre-production) machines being built at the time. For that reason, body panels and/or parts from the machin...

  • Page 9

    Installation spirit installation manual page 8 prior to installation area preparation before unpacking the machine, you must be sure that the area where the machine will be placed has been prepared properly. The countertop should be level and firm enough to carry the weight of the machine (up to 135...

  • Page 10

    Installation spirit installation manual page 9 figure 4. Footprints of spirit duette (top) and triplette (bottom). Measurements in millimetres. Black circle ……………………… machine foot (diameter = 50 mm) white rectangles ………………... Suggested locations for openings behind front feet to feed connections thr...

  • Page 11

    Installation spirit installation manual page 10 figure 5. Measurements of spirit duette. Note that the rubber feet are not present, these are 20 mm high and have a diameter of 50 mm. W ith o ut ru b b e r f e e t 20 m m h igh w ith o ut ru b b e r f e e t 20 m m h igh.

  • Page 12

    Installation spirit installation manual page 11 figure 6. Measurements of spirit triplette. Note that the rubber feet are not present, these are 20 mm high and have a diameter of 50 mm. W ith o ut ru b b e r f e e t 20 m m h igh w ith o ut ru b b e r f e e t 20 m m h igh.

  • Page 13

    Installation spirit installation manual page 12 upon arrival parts included in standard shipment  spirit espresso machine accessories  2* water pumps with electric motors  2* high-pressure, steel webbed, hoses, each 1.5 m (5 ft)  3* high-pressure, steel webbed, hoses, each 0.5 m (1 ft 8 in)  1*...

  • Page 14

    Installation spirit installation manual page 13 figure 7a (left). Adjust the height of an individual leg. Loosen the cover nut, “unscrew” the foot from the leg until correct height is reached, then tighten cover nut. Figure 7b (right). Location of water supply connections between left legs of machin...

  • Page 15

    Installation spirit installation manual page 14 installation precaution installation of and maintenance on the spirit should only be undertaken by a qualified technician. Parts of the machine can reach a temperature of close to 130 °c (266 °f). The steam/hot water boiler contains water and pressuris...

  • Page 16

    Installation spirit installation manual page 15 connect water supply connect your water mains to the inlet of an efficient device to remove calcium and magnesium ions and chlorine from the water entering your machine. Scale and chlorine are the worst enemies of an espresso machine. Be sure to rinse ...

  • Page 17

    Installation spirit installation manual page 16 7. Fill/rinse the water treatment system (also when new) until the water runs clear (see the manual of your water treatment system for this procedure). 8. Where appropriate: check the quality of your incoming tap water and adjust the “bypass” on your w...

  • Page 18

    Installation spirit installation manual page 17 figure 10. Lay-out of hoses, fittings and pumps for the standard spirit (one pump for steam/hot water system, one pump for the coffee-system) and for spirits with an individual pump for each group. 2 steam group l group m group r water faucet water fil...

  • Page 19

    Installation spirit installation manual page 18 connect water discharge t he machine is equipped with two discharge hoses of small diameter. This allows for “hiding” of the discharge behind the left hand front leg of the machine. 1. Position the stainless steel hose clamp on one end of the discharge...

  • Page 20

    Installation spirit installation manual page 19 connect electrics single- versus three-phase machines the spirit is designed to operate on 220-240vac with three-phase mains power (3x 230vac) so as to divide power consumption over three different mains leads. The mains cable has five wires (2.5 mm 2 ...

  • Page 21

    Installation spirit installation manual page 20 mains switch the function of position “no heat” of the mains switch is that only a small portion of the machine (pumps, main controller, back-side led-light) will get power which allows for testing without heat. Only in position “on”, can power be fed ...

  • Page 22

    Installation spirit installation manual page 21 3-phase 1- phase usa live l1 brown black l2 black brown l3 grey neutral n blue blue white* earth p e yellow/ green yellow/ green green figure 14. Shown here is the 3-phase plug (3p+n+e 16a 400v) used in europe. * the white lead in the usa cable must be...

  • Page 23

    Installation spirit installation manual page 22 note on phase shift of 120vac (or 115vac)! When you want to use your machine in a 120vac or 115vac environment, check whether the mains is a 180 degrees phase shift (most houses) or a 120 degrees phase shift (most commercial buildings). You can measure...

  • Page 24

    Installation spirit installation manual page 23 filling the machine with water from empty several jets and restrictors are present within the machine. These jets and restrictors slow down the flow within the machine in order to optimise the coffee extraction process in terms of pressure profiling an...

  • Page 25

    Installation spirit installation manual page 24 6. Turn the mains switch to “off” (to reset the main controller) and back to “no heat”, the steam/hot water boiler will continue filling after a 3 second delay. 7. Repeat step 5 and 6: continue activating the groups (one by one) until water flow from a...

  • Page 26

    First use spirit installation manual page 25 first use heating up heating up all of the boilers takes about 25 minutes after the temperature controllers are turned “on”. When the temperature in the steam boiler reaches boiling point, some steam will escape through the anti-vacuum valve and is discha...

  • Page 27

    First use spirit installation manual page 26 if you wait longer than 5 seconds, the controller will leave programming mode automatically (all led’s unlit). Use of a stopwatch is advised.  press down and release the hot water lever again when the desired quantity of water has been dispensed. The ele...

  • Page 28

    First use spirit installation manual page 27 figure 16. Showing the set screw on the pump to change pump pressure. Notes! Do not set the pump pressure with a blind filter in the filter holder. When a blind filter is used, water in the system is trapped between a one-way valve and the blind filter. T...

  • Page 29

    First use spirit installation manual page 28 2. Get the main controller in programming mode (to get a long lasting flow of hot water): touchpad: press and hold upper button on left hand touchpad; bastone-autostop: two-way switch of left hand group in left position, press and hold program button for ...

  • Page 30

    Information spirit installation manual page 29 more information on our website plea se check the “spirit user manual” for information on how to operate the machine (set brew volumes and remarks thereabouts, adjust steam power, change temperature settings, etc.). Http://www.Keesvanderwesten.Com/asset...