  • Page 1

    Operating manual • english käyttöohje • suomi bruksanvisning • svenska bruksanvisning • norsk brugsanvisning • dansk gebrauchsanweisung • deutsch gebruiksaanwijzing • nederlands manuel d’utilisation • français manual de instrucciones • español instrukcja obsługi • polski Инструкции по эксплуатации •...

  • Page 3: Operating Manual

    Operating manual english m ast er tig mls 2300 a cdc / © kemppi o y / 1112.

  • Page 4

    En contents 1. Preface ................................................................................................................................ 3 1.1 general .........................................................................................................................................

  • Page 5

    En 1. Preface 1.1 general congratulations on your choice of the kemppi mastertig mls acdc welding system. Reliable and durable, kemppi products are affordable to maintain, and they increase your work productivity. This user manual contains important information on the use, maintenance and safety of ...

  • Page 6

    En 2. Installation 2.1 removal from packaging the equipment is packed in durable packages designed especially for it. However, it is necessary to check the equipment before using it to make sure that the equipment or any part of it has not got damaged during transportation. Also check that the deliv...

  • Page 7

    En front of machine 1. Function panel 2. Remote control connector 3. Tig torch control connector 4. Shield gas and current connector for tig torch 5. (+) connector for electrode holder 6. (–) connector for earth cable markings for (+/–) poles on the machine front are embossed. Rear of machine 1. Mai...

  • Page 8

    En 2.6 mains connection note! Only an authorised electrician is allowed to install mains cable and plug! The machine comes equipped with a three-metre power cord with a schuko plug. Only an authorised electrician is allowed to replace the plug. The fuse and cable sizes are given in the technical dat...

  • Page 9

    En installation of cooling unit: electrical connection for the cooling unit: 1. 3. 2. 1. 230 v 2. Control connector 3. Equipment earth note! Only an authorised electrician is allowed to install electrical connection! 7 m ast er tig mls 2300 a cdc / © kemppi o y / 1112.

  • Page 10

    En 2.10 shield gas note! Handle gas bottle with care. There is a risk for injury if gas bottle or bottle valve is damaged! Use inert gases such as argon, helium or argon-helium mixture as shield gas for tig welding. Make sure that the gas flow regulator is suitable for the gas type used. The flow ra...

  • Page 11

    En 3. Operation note! Welding in places presenting an immediate fire or explosion hazard is forbidden! Note! Welding fumes may cause injury, take care of sufficient ventilation during welding! 3.1 welding processes 3.1.1 mma welding with mastertig mls™ acdc power sources you can use all electrodes s...

  • Page 12

    En 3.1.4 synergetic pulsed tig welding the acx panel includes the synergetic tig process, in which you only need to adjust the welding current while other pulse parameters are programmed. Pulsing frequency is high, which guarantees concentrated arc and increased welding speed. 3.1.5 long pulsed tig ...

  • Page 13

    En acs welding panel – basic functions 1. 4. 5. 6. 8. 9. 7. 11. 10. 3. 2. 12. 13. 14. 15. 16. 17. 1. Selection button and indicators for tig welding and current type 2. Selection button and indicators for mma welding and current type 3. Current and voltage display, display for other welding paramete...

  • Page 14

    En 1. Dynamics (“arc” –9 … 0 … +9) you will see the numerical value corresponding to the mma dynamics in the display. Factory setting for all electrode types is zero. You can change the value by turning the pulse potentiometer. If numerical value is adjusted negative (-1...-9) the arc is softened, a...

  • Page 15

    En 3. Mix tig (mixed current ac/dc-) with mixed current frequency and balance of alternating current are determined by adjustments made for ac-current. Adjust by choosing sections 4. – 5. If needed. The following quick setup parameters can be adjusted: 1. Ac-time (ac 10 ... 90 %, factory setting 50 ...

  • Page 16

    En welding panel acx – pulsed tig and minilog function with memory 2. 1. 3. 4. 7. 8. 9. 11. 5. 10. 6. 12. 13. 14. 1. 4t-log and minilog function selections 2. Search arc 5 – 90 % of welding current 3. Start-current 80 – 150 % 4. Minilog-current 10 – 150 % of welding current 5. Tail arc 5 – 90 % of w...

  • Page 17

    En minilog when torch switch is pressed gas flow starts. When you release the torch switch current goes through upslope to hot start or soft start -current depending on adjustments and by pressing shortly again to welding current. After another short press it goes to minilog operation, and you can s...

  • Page 18

    En 3.2.4 adopting the saved settings 1. Select memory by pressing the button. 2. Select memory channel by pressing the ch button. 3. Start welding. 3.2.5 remote control memory channels memory channels are selected by pressing simultaneously both remote and ch button. With the remote control you can ...

  • Page 19

    En 3.5 setup-functions setup-function display *c = common: applies to all memory channels factory setting with a grey background upslope current dependency (*c) a1 on the upslope time is determined by the current. Off the upslope time remains as set. Downslope current dependency (*c) a2 on the downs...

  • Page 20

    En 3.6 error codes the machine always checks its operation automatically during start-up and reports any failures detected. If failures are detected during start-up, they are shown as error codes on the control panel display. Err3: overvoltage or undervoltage the machine has stopped the welding beca...

  • Page 21

    En 4.2 troubleshooting power on light is not lit. There is no power in the machine. • check mains fuses, replace blown fuses. • check mains cable and plug, replace defect parts. The machine is not welding properly. There are plenty of spatters during welding. Weld joint is porous or power supply is ...

  • Page 22

    En 5. Ordering numbers power source mastertig mls™ 2300 acdc 6162300 panels acs 6162805 acx 6162804 cabels welding cable 16 mm² 5 m 6184103 welding cable 25 mm² 5 m 6184201 welding cable 25 mm² 10 m 6184202 welding cable 35 mm² 5 m 6184301 earth cable 16 mm² 5 m 6184113 earth cable 25 mm² 5 m 618421...

  • Page 23

    En 6. Technical data power source mastertig mls™ 2300 acdc connection voltage 1~230 v –15%…+15% rated power 40% ed tig 230 a 5,7 kva 60% ed tig 200 a 4,8 kva 100% ed tig 170 a 3,9 kva 40% ed mma 180 a 6,0 kva 60% ed mma 150 a 4,8 kva 100% ed mma 120 a 3,7 kva connection cable h07rn-f 3g2.5 (3.3 m) f...

  • Page 24

    En power source and cooling unit operating temperature range -20 °c .... +40 °c storage temperature range -20 °c .... +60 °c emc class a degree of protection ip 23 c recommended generator smin 8 kva 22 m ast er tig mls 2300 a cdc / © kemppi o y / 1112.

  • Page 25

    En 23 m ast er tig mls 2300 a cdc / © kemppi o y / 1112.

  • Page 26

    1910032 1112 www.Kemppi.Com kemppi oy hennalankatu 39 pl 13 fin-15801 lahti finland tel +358 3 899 11 telefax +358 3 899 428 export@kemppi.Com www.Kemppi.Com kotimaan myynti: tel +358 3 899 11 telefax +358 3 734 8398 myynti.Fi@kemppi.Com kemppi sverige ab box 717 s-194 27 upplands vÄsby sverige tel ...