File: 091-150 date: 06-05-02 rev. Instruction manual auto pump timer a timer to limit the running time of the auto pump model# 091-150 input: 12volts, d.C. Output relay: 30 amps 3 year warranty.
Introduction the model 091-150 auto pump timer limits the duty cycle of the auto pump to 1 hour on and 1 hour off. This is important to the life of the pump when it is operating on a vehicle with an abnormally high leak. The unit prevents the pump from operating at higher temperatures, and thus pres...
Specification and outline input power: 12vdc (from pressure switch input to relay com). Input current draw: 80 ma. With pump running, 10 ma. With pump resting. Relay contact rating: 30 amps @ 14 vdc weight: 4 ounces figure 2 3/16" dia. Outline drawing 4,50 1.55 2.95 5.10
Pressure switch auto pump air compressor make sure the auto pump is mounted vertical. Note: red +12 volts black -12 volts o p t i o n a l f u s e o p t i o n a l s w i t c h c h a s s i s g r o u n d c h a s s i s g r o u n d c h a s s g r o u n range nut n.C. N.O. C 091-150 auto pump timer figure 1...
Installation record & warranty date installed ________________________________________ installed by ___________________________________________ vehicle identification _________________________________ vehicle owner ________________________________________ warranty all products of kussmaul electronic...