KUSSMAUL 091-215-12 Instruction Manual

Manual is about: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER

Summary of 091-215-12

  • Page 1

    File: im_091-215-12_revg.Indd rev: g revised by: so, pg 6&7 date: 05-13-2016 auto charge 1000 plc automatic single output battery charger scan using your mobile device for more information instruction manual input: 120 volt, 60 hz, 3.5 amps output battery 1: 15 or 18 amps output battery saver: 3 amp...

  • Page 2

    Important safety instructions i. Personal precautions: 1. Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. 2. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. 3. Wear complete eye...

  • Page 3

    Introduction the auto charge 1000 with parasitic load compensation (plc) is a compact, microprocessor controlled, com- pletely automatic, single channel battery charger designed for vehicles with a single battery system. The plc charger is designed to withstand the shock and vibration encountered by...

  • Page 4

    Wiring and switch settings i. Battery charger wiring instructions 1. Refer to installation wiring diagram i & ii. 2. Refer to wiring specifications to determine the recommended wire size and maximum lengths. Using a smaller gauge may cause overheating of the terminal. Additional information is avail...

  • Page 5

    V. Battery saver and battery saver switch a low ripple, current limited, 3 ampere battery saver is built into the charger. When connected as shown in the installation wiring diagram, loads on the battery such as radios and rechargeable hand lights are automatically switched to the battery saver when...

  • Page 6: Parasitic Load

    170 cherry avenue west sayville, ny 11796 www.Kussmaul.Com ph: 800-346-0857 fax: 631-567-5826 sales@kussmaul.Com 5 = 1 o n on off switch shown in off position 1 2 3 4 5 6 7 8 0 amps float lead 0ff parasitic load compensation battery saver 3 step timer battery type 170 cherry avenue west sayville, ny...

  • Page 7: 1000 Plc

    Installation wiring diagram i. For standard bar graph display, 091-199-001 or optional deluxe status center, 091-194b-ind wiring diagram shown is for a 10 foot installation 6 black (12awg) red (12awg) red (12awg) ac connections shall comply with ul recommendations, nec, or nfpa standards accessories...

  • Page 8: 1000 Plc

    Ii. For optional watertight deluxe status center, 091-194b-ind-wt-xx wiring diagram shown is for a 10 foot installation 7 1 - red 20awg 2 - black 20awg 3 - white 20awg 4 - green 20awg remote indicator 1 - red 20awg 2 - black 20awg 3 - white 20awg 4 - green 20awg black (12awg) red (12awg) red (12awg)...

  • Page 9

    Specifications input power: 120 volt, 60 hz, 3.5 amperes input fuse: 6 ampere, fast blow output power - bat : 15 amperes max (18 amperes if battery saver is turned off) battery type float v dc absorbtion v dc lead-acid 13.25 14.00 gelled electrolyte 13.50 14.25 agm 13.50 14.40 odyssey® 13.60 14.70 o...

  • Page 10

    Outline drawing 170 cherry avenue west sayville, ny 11796 www.Kussmaul.Com ph: 800-346-0857 fax: 631-567-5826 sales@kussmaul.Com 9.

  • Page 11

    Optional accessories i. Standard bar graph display, model #: 091-199-001 • 10-segment led display indicate the “state of charge” and the general condition of the batteries ii. Optional deluxe status center, model #: 091-194b-ind • indicator has a digital voltage and ampere display • 5 segment bar gr...

  • Page 12

    Installation record date installed _______________________________________________________ installed by _________________________________________________________ vehicle identification _______________________________________________ vehicle owner _____________________________________________________...