KUSSMAUL 091-3510 Instruction Manual - page 6
A.C. FUSE
POWER
INPUT
OUTPUT
L
N
BATTERY SAVER
REMOTE
B.S
BAT1
Battery Saver Loads
( 1 0 a m p s m a x . ) .
W h e n t h e c h a r g e r
is disconnected from
1 2 0 v o l t s A C t h e
B at te r y S a ve r lo a ds
a u t o m a t i c a l l y a r e
connected to battery #1.
Chassis
Ground
Chassis
Ground
+ 12 V
olts
Accessories
4
3
2
1
To 120 volts A.C.
Indicator
Auto Charge 35/10
CONNECTION
DEFINITION
WIRE SIZE
A.C.
120 VOLTS A.C.
14 AWG
COM
GROUND LINE
8 AWG
BAT 1
POSITIVE CHARGING LEAD VEHICLE BATTERY 1
8 AWG
BATTERY SAVER
POSITIVE OUTPUT
14 AWG
IMPORTANT: Wire size is for a maximum lenght of 10 feet. If longer, larger wiring is required.
Wire Chart
NOTE: Minimum wire size on charger
output and ground is
Smaller
gauge wire may cause overheating of
terminal. Use GS 7-13 eyelet over wire
to simplify insertion of wire into terminal
strip and to improve connection.
#8 AWG.
Strip insulation
15/32 so that
wire strands are
flush with end of
eyelet, 2 places,
Installation Wiring Diagram