  • Page 1

    Instruction manual tel: in ny 631-567-0314 toll free: 800-346-0857 fax: 631-567-5826 1 year warranty book# 091-9-086 inst.Book aug. 3, 2005 kussmaul electronics co., inc . 170 cherry ave., west sayville, n.Y. 11796 auto drain an automatic moisture drain for the 091-9 air compressor model #091-9-086 ...

  • Page 2

    Introduction the auto drain system consists of a 12 volt normally open solenoid, a filter and assorted fittings. Designed to work with the 12 volt auto pump, the solenoid bleeds the filter bowl when the pump is not running. As soon as the pressure switch turns on the compressor, the solenoid is ener...

  • Page 3

    091-9-086 auto drain installed on 091-9 auto pump note: 1. Install pressure switch on auto drain before installing auto drain on pump. 2. It may be necessary to slightly rotate solenoid valve to clear pressure switch when installing..

  • Page 4

    1. Install the black sleeving over the solenoid wires 2. Connect the auto drain solenoid wires to output terminals of pressure switch. These are the same terminals that supply power to the auto pump motor 3. The auto drain is now properly connected. Test by bleeding system pressure to start auto pum...

  • Page 5

    Installation record & warranty date installed installed by vehicle identification vehicle owner all auto pumps of kussmaul electronics company inc. Are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any mater...