  • Page 1

    Congratulations! You have purchased the finest circulating construction heater available. Your new l.B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology. We, at l.B. White, thank you for your confidence in our product...

  • Page 2

    Warning fire and explosion hazard ■ not for home or recreational vehicle use. ■ installation of this heater in a home or recreational vehicle may result in a fire or explosion. ■ fire or explosions can cause property damage or loss of life. For your safety if you smell gas: 1. Open windows. 2. Don't...

  • Page 3

    This owner's manual includes all options and accessories commonly used on this heater. However, depending on the configuration purchased, some options and accessories may not be included. When calling for technical service assistance, or for other specific information, always have model number, conf...

  • Page 4

    Ssppeecciiffiiccaattiioonnss maximum input (btuh) 400,000 365,000 1,600 cfm 1,600 cfm 18 7 46 x 25 x 36 top 7 ft. Sides 5 ft. Back 5 ft. Blower outlet gas supply 150 155 156 161 333344 333366 l.P. Natural gas gas m mooddeell ventilation air required to support combustion net weight (lbs.) shipping w...

  • Page 5

    Llpp ggaass aanndd nnaattuurraall ggaass hhaavvee m maann--m maaddee ooddoorraannttss aaddddeedd ssppeecciiffiiccaallllyy ffoorr ddeetteeccttiioonn ooff ffuueell ggaass lleeaakkss.. Iiff aa ggaass lleeaakk ooccccuurrss,, yyoouu sshhoouulldd bbee aabbllee ttoo ssm meellll tthhee ffuueell ggaass.. Tth...

  • Page 6

    1. Do not attempt to install, repair, or service this heater or the gas supply line unless you have continuing expert training and knowledge of gas heaters. Qualifications for service and installation of this equipment are as follows: a. To be a qualified gas heater service person, you must have suf...

  • Page 7

    1. Read all safety precautions and follow l. B. White recommendations when installing this heater. If during the installation or relocating of heater, you suspect that a part is damaged or defective, call a qualified service agency for repair or replacement. 2. Make sure the heater is properly insta...

  • Page 8

    Channel tabs bolt hold down bracket fig. 1 7. A qualified service agency must check for proper operating gas pressure upon installation of the heater. 8. Light according to instructions on heater or within owner's manual. 9. Make sure the heater has the proper gas regulator for the application. A re...

  • Page 9

    Hose regulator to he at er to ma nif ol de d l.P . G as su pp ly cy lin de r s ys te m manual shut-off valve, hose and regulator assembly 1. Always use approved pipe thread compound suitable for use with l.P. Gas or natural gas on the threaded connections. 2. Assemble the components together accordi...

  • Page 10

    1100 1. The area surrounding the heater shall be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 2. Have your gas supplier check all gas piping annually for leaks or restrictions in gas lines. 3. Regulators must be periodically inspected to make sure...

  • Page 11

    Service instructions aa.. Bbuurrnneerr oorriiffiiccee 1. Initial preparation a. Close fuel supply valves to heater. B. Allow heater to burn off remaining fuel in its gas supply line. C. Disconnect hose from heater. D. Allow heater to cool. 2. Orifice removal a. Loosen retaining bolt which secures bu...

  • Page 12

    C. Remove the pilot orifice screen at the inlet of the orifice prior to cleaning. Reinstall the screen after cleaning. D. Ensure pilot orifice holes are not plugged with dirt or other materials. Clean the pilot orifice or replace if necessary. The replacement orifice ships with an orifice screen. 3....

  • Page 13

    Attention this procedure is to be done once a year prior to the heating season, anytime the heater is moved from one job location to the next, or after servicing the heater. Materials required (to be secured through local purchase) qquuaannttiittyy ddeessccrriippttiioonn 1 high pressure gas gauge ca...

  • Page 14

    1144 problems causes remedies 1. Pilot will not light. * lp-gas tank empty. * fill lp-gas tank. * gas supply valve closed. * open supply valve. * pilot control valve button not fully * fully depress the pilot button. Depressed. * restriction in gas hose. * replace hose or blow out with compressed ai...

  • Page 15

    1155 heater component function burner cast iron component used to channel gas and provide an area at which the fuel may ignite. Burner orifice brass metering device used to feed gas to burner at a specific rate. Fan component used in conjunction with the motor to pull the hot air from heater and blo...

  • Page 16

    1166 l.P. Gas burner assembly nat. Gas burner assembly 24 23 21 22 20 17 18 16 15 16 15 14 11 12 13 19 9 8 7 6 5 1 26 10 14 10 11 5 6 7 8 9 19 1 2 3 4 12 13 17 18 25 27 parts identification parts schematic.

  • Page 17

    Parts list model item description 334 336 1 regulator l.P. Gas 21788 -- nat. Gas --- 01104 2 adaptor, hose 01098 -- 3 hose 1/4 in. X 10 ft. 22129 -- 1/2 in. X 10 ft. -- 20704* 4 adaptor, hose 07970 -- 5 valve, pilot safety -----------------07966----------------- 6 ell, w/ nut & sleeve --------------...

  • Page 18

    Contact your local l.B. White dealer for replacement parts and service or call the l.B. White co., inc. At 1-800-345-7200 for assistance. Be sure that you have your heater model number and configuration number when calling. 1188 l.B. White co., inc. Warrants that the component parts of its heater ar...