L.B. White Tradesman 170 Owner's Manual And Instructions - page 21
Three Times
I
ndicates ignition
failure.The ignition
control is in safety
lockout..
Is pr
oper fuel
supplied t
o
heat
er
inlet?
Connect pr
oper
gas supply t
o
heat
er
. Open all
gas shut
of
f v
alv
es.
Is pr
oper gas
pressure supplied
to
heat
er?
Pr
o
vide pr
oper gas supply
pressure t
o
heat
er
. R
e
fer t
o
dataplat
e. If LP gas is used,
ensure LP container is full.
Is backflash
switch tripped?
Check
continuity
Is Ignit
or
pr
operly
gapped?
Is pr
oper
v
oltage
supplied t
o
gas v
alv
e?
Def
ectiv
e gas
v
alv
e.
Check ignit
er gap
R
egap t
o
4.7
mm.
Def
ectiv
e wires or
connections. If good,
replace ignition contr
ol.
Does ignit
or
spark?
Is ignit
er high v
oltage
lead securely
connect
ed?
R
eposition
Ignit
er
.
(See Ser
vice
Instructions)
Connect high v
oltage lead
21
Five Times
If contr
ol module does no
t reset, then replace it (Int
ernal boar
d
fault.)
If module resets, then ha
v
e
q
ualif
ied electrician check po
w
e
r
sour
ce f
or po
w
er q
uality pr
oblems. (F
req
uency
, line noise, line
spik
es, loose connections, t
oo small wire gauge.)
Flame sense relat
ed pr
oblems. Check f
o
r
crack
ed or dir
ty flame sensor
, im
pr
operly
positioned sensor
, or poor flame sense gr
ound.
Four Times
Rapid On/Off
cycling of the
burner.
Does gas
solenoid v
a
lv
e open?
TRADESMAN U
L
TRA HEATER
Problem
Is the heat
er
pr
operly
gr
ounded?
No
Ensure all
gr
ounds are
connect
ed.
Det
ermine if ignit
or receiv
es high v
oltage:
-- Disconnect ignition lead fr
om ignition contr
ol.
-- P
osition a scre
wdriv
er tip about 4.7 mm a
w
a
y
fr
om ignition contr
ol where lead w
as connect
ed .
-- WITH GAS OFF
, star
t the heat
er
.
-- If no spark is seen, replace the igntion contr
ol.
-- If spark is seen, reconnect igntion lead t
o
contr
ol.
-- Disconnect the lead at the ignit
or
.
-- Hold the lead about 4.7 mm fr
om a gr
ounded
section of the heat
er
.
-- WITH GAS OFF
, star
t the heat
er
.
-- If no spark is obser
v
ed, replace the ignition lead.
-- If spark is obser
v
ed, replace the ignit
or
.
Is ignit
or gap
positioned
to
w
a
rd
burner
orif
ice?
No
No
No
No
No
No
No
No
No
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Check continuity acr
oss
switch. If contacts are
open det
ermine cause.
Check f
or:
pr
oper v
oltage, block
ages
at air inlets or outlet, loose
fan, or lo
w f
an speed.
If good, repalce backflash
switch.
Ye
s
Check the burner orif
ice
for block
age. Clean or
replace the orif
ice .
Summary of Tradesman 170
Page 1
Models output (kw) fuel cp170 49.8 45.4 congratulations! You have purchased the finest portable forced air construction heater available. Your new l.B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology. We, at l.B. Whi...
Page 2
Warning fire and explosion hazard ■ not for home or recreational vehicle use. ■ installation of this heater in a home or recreational vehicle may result in a fire or explosion. ■ fire or explosions can cause property damage or loss of life. For your safety if you smell gas: 1. Open windows. 2. Don't...
Page 3
Section page general information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 heater specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 4
Maximum / minimum input (kw) 49.8 /36.6 45.4/36.6 2.74 1.37 2.76 3.36 2.76 1.74 3.56 kg 4.38 m3 2.63 kg 3.53 m3 3.7 2.14 top 1.83 sides .92 back .92 blower outlet (meters) gas supply 3.05 n/a 50 watts, 3,200 rpm sleeve bearing cp170 propane natural gas gas specifications model electrical supply (vol...
Page 5
Propane gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs, you should be able to smell the fuel gas. That’s your signal to go into immediate action! ■ do not take any action that could ignite the fuel gas. Do not operate any electrica...
Page 6
1. Do not attempt to install, repair, or service this heater or the gas supply line unless you have continuing expert training and knowledge of gas heaters. Qualifications for service and installation of this equipment are as follows: a. To be a qualified gas heater service person, you must have suf...
Page 7
1. Read all safety precautions and follow l. B. White recommendations when installing this heater. If during the installation or relocating of heater, you suspect that a part is damaged or defective, call a qualified service agency for repair or replacement. 2. Ensure the heater is properly position...
Page 8
Assemble handle to four holes at barrel top as shown in fig.1. Tighten screws securely. Fig. 1 handle assembly 8 the vaporization of propane is affected by several factors: the sur face area of the container, the liquid level of propane, temperature surrounding the container, and the relative humidi...
Page 9
9 1. Ensure the cylinder valve is completely closed. 2. Remove the protective cap from regulator fitting. Do not discard cap. 3. Insert pol stem into the valve on the cylinder. Thread the nut counterclockwise into the tank valve. Ensure regulator vent is pointed down. Tighten the nut securely with a...
Page 10
This heater includes a height adjustment feature, allowing the user to change the elevation of the heater for greater heat direction. See fig. 6 for location of adjustment on front base of heater. To adjust the heater’s nose height: -- loosen knob -- lift heater slightly at blower outlet end -- pull...
Page 11
Start-up instructions 1. Connect the heater’s electrical cord to an approved electrical outlet. 2. Open the gas supply valve. For lp heaters, this is located on the cylinder or tank. 3. Set thermostat on heater to a setting above room temperature. The heater will start and the burner will ignite. ■ ...
Page 12
1. The area surrounding the heater shall be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 2. Have your gas supplier check all gas piping annually for leaks or restrictions in gas lines. 3. Regulators must be periodically inspected to make sure the ...
Page 13
Service instructions 1. Close the fuel supply valve to the heater and disconnect the electrical supply before servicing unless necessary for your service procedure. 2. Remove the heater’s base bottom for access to electrical components and connections. 3 disconnect the appropriate electrical leads f...
Page 14
14 14 1. Loosen the compression nut at the outlet of the variable rate valve. See fig. 13. 2. Remove both screws securing the valve bracket to the heater side panel. 3. Remove the valve assembly from the heater and replace components as needed. Fig. 13 variable rate valve and gas control valve screw...
Page 15
2. Loosen the compression nut at the burner orifice. Remove the bowed retaining clip. See fig. 17. Fig. 17 2. Reach down the barrel of the heater and pull the orifice from the burner plate. 3. Inspect the orifice and clean any plugged holes. Replace it if necessary. The replacement orifice will incl...
Page 16
Ignition control 1. Disconnect the led wire harness from the circuit board, if applicable. 2. Remove the nuts securing the control to the side of the heater’s base.. See fig. 21. 3. When replacing, do not touch or allow contact to the control’s components, otherwise damage may occur. Fig. 21 14 16 1...
Page 17
17 ■ the following explains a typical procedure to be followed in checking gas pressures. ■ the gas pressures will vary depending upon fuel type. ■ consult the dataplate on the heater or page 4 in this manual for specific pressures to be used in conjunction with this procedure. ■ gas pressure measur...
Page 18
Read this entire section before beginning to troubleshoot problems. The following troubleshooting guide provides systematic procedures for isolating equipment problems. This guide is intended for use by a qualified gas heater service person. Do not attempt to service these heaters unless you have be...
Page 19
19 tradesman u l tra heater red l ight constant on l ed light not on normal operation does f a n mo tor run? Ye s ye s does heat er light? Led light def ectiv e r eplace led is thermostat set abo v e r oom te m perature? Set thermostat abo v e r oom te m perature. Is pr oper v oltage supplied t o he...
Page 20
Two times indicates lack of air proving in fan section ( f lash pattern begins within 90 seconds after condition occurs). Do air pr o ving switch contacts close? Check continuity . R emo v e dir t. Repair or replace f an. Is f an binding, or bent, or cak ed with dir t? No is f an loose on mo tor sha...
Page 21
Three times i ndicates ignition failure.The ignition control is in safety lockout.. Is pr oper fuel supplied t o heat er inlet? Connect pr oper gas supply t o heat er . Open all gas shut of f v alv es. Is pr oper gas pressure supplied to heat er? Pr o vide pr oper gas supply pressure t o heat er . R...
Page 22
22 tradesman heater f an motor does not run, heater does not light. Is pr oper v oltage supplied t o heat er? Pr o vide pr oper v oltage t o heat er . Check breajer and e xt ension cor ds. No is thermostat set abo v e r oom te m perature? Set thermostat abo v e r oom te m perature is pr oper v oltag...
Page 23
F an runs, heater does not light. Open fuel supply v a v es . Pr o vide pr oper gas pressure t o heat er inlet. Check continuity acr oss switch. If contacts are open det ermine cause. Check f or: pr oper v oltage, block ages at air inlets or outlet, loose fan, or lo w f an speed. If good, repalce ba...
Page 24
24 electrical connection and ladder diagrams white black case ground motor solenoid gnd ground mv valve solenoid burner ground direct sense igniter ground direct spark ignition control thermostat valve mv electrical ladder diagram if any of the original wires as supplied with the heater must be repl...
Page 25
Heater component function air proving switch safety device used to insure that the proper air flow is being achieved before the gas valve is opened. Auto reset limit switch safety device wired into the control system which is used to break an electrical circuit to the gas control valve in event of o...
Page 26
26 parts schematic parts identification.
Page 27
27 parts list part number tradesman 170 tradesman 170 item description ultra 1a regulator with pol (propane gas) 28276 1b regulator (natural gas) 29680 2 hose, fixed x swivel, 9.5 mm id x 5.2 m (propane gas ) 22278 hose, fixed x swivel, 12.7 mm x id x 5.2 m (natural gas) accessory 22538 3a adaptor, ...
Page 28
28 contact your local l.B. White dealer for replacement parts and service or call the l.B. White co., inc. At 1-800-345-7200 for assistance. Be sure that you have your heater model number and configuration number when calling. L.B. White co., inc. Warrants that the component parts of its heater are ...
Page 29
ModÈle puissance (kw) combustible cp170 49,8 45,4 félicitations! Vous avez fait l’acquisition du meilleur appareil de chauffage à pulsion d’air sur le marché. Votre nouvel appareil l.B.White a été construit par une entreprise fière et expérimentée qui utilise une technologie de pointe dans la fabric...
Page 30
2 attention risque d'incendie ou d'explosion ■ non-recommandé pour un usage résidentiel ou dans un véhicule récréatif. ■ l’utilisation de cet appareil dans une résidence ou dans un véhicule récréatif peut entrainer des risques d’incendie ou d’explosion. ■ un incendie ou une explosion peuvent entaine...
Page 31
Section page information généralités . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 specifications de l ’appareil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 32
Puissance maximum/minimum (kw) 49,8/36,6 45,4/36,6 2,74 1,37 2,76 3,36 2,76 1,74 3,56 kg 4,38 m3 2,63 kg 3,53 m3 3,7 2,14 61 x 22,9 x 40,6 dessus 1.83 cotes ,92 arriere ,92 orifice de sortie du ventilateur reservoir de combustible pallier à coussinet-douille, moteur à bague de déphasage cp170 gaz ga...
Page 33
5 le gaz propane ainsi que le gaz naturel ont été intentionnellement additionnés d’additifs odorants permettant leur identification et la détection de fuites possibles. Advenant une fuite, il est donc fort probable que vous puissiez sentir la présence de gaz dans l’air ambiant. VoilÀ votre signal-un...
Page 34
1. Ne pas entreprendre d’installer ou d’effectuer des travaux d’entretien ou de réparation sur cet appareil ou sur la ligne d’alimentation en gaz, à moins d’être un expert qualifié dans l’utilisation et le service d’appareils au gaz. Les compétences requises pour effectuer l’entretien ou la réparati...
Page 35
Utiliser l’appareil. Le boyau d’alimentation en gaz doit être à l’abri d’accumulation de débris de construction ainsi que de surfaces très chaudes. L’assemblage du b oya u d ’ a l i m e n t a t i o n d o i t ê t r e e n to u s p o i n t s conformes aux spécifications du manufacturier. Voir la liste ...
Page 36
1. Lire toutes les consignes de sécurité et suivre les recommandations de l.B. White lors de l’installation de votre appareil de chauffage. Si, au cours de l’installation ou en déplaçant l’appareil, vous constatez une anomalie ou le bris d’une pièce, contactez un technicien qualifié pour en effectue...
Page 37
-- serrer les branchements et les joints. -- si la fuite persiste, remplacer la pièce en cause. -- s ’ a s s u r e r qu e to u te s l e s f u i te s o n t é t é identifiées et colmatées avant de continuer d’opérer l’appareil. 9. Une vérification de la pression du gaz doit être e f fe c t u é e p a r...
Page 38
-- brancher les composantes et le détendeur à la prise d’entrée du gaz, tel qu’illustré à la fig. 4. S’assurer que la flèche sur le détendeur, indiquant la direction du débit de gaz indique bien la direction du gaz vers l’appareil. Serrer ferment les branchements. Fig. 4 1. S’assurer que la valve (r...
Page 39
L’appareil de chauffage comprend un dispositif d ’ a j u s te m e n t d e l a h a u te u r, c e qu i p e r m e t à l’utilisateur de modifier l’élévation de l’appareil pour permettre un meilleur contrôle de la direction de la c h a l e u r. C o n s u l te r l a f i g u r e 6 p o u r c o n n a î t r e...
Page 40
Instructions de mise en marche 1. Brancher le cordon électrique dans une prise de courant homologuée. 2. Ouvrir la valve d’alimentation en gaz. Pour les chauffe-eau de lp, la soupape est localisée sur le réservoir. 3. Régler le thermostat de l’appareil de chauffage à une température supérieure à cel...
Page 41
Attention il ne faut pas utiliser un nettoyeur à haute pression, de l’eau ou une solution de nettoyage sur les commandes de gaz. L’utilisation d’un nettoyeur à haute pression, d’eau ou d’une solution de nettoyage sur les commandes peut entrainer des blessures ou des dégats matériels. L’eau ou tout l...
Page 42
1. Retirer les vis retenant le support du moteur au châssis de l’appareil de chauffage. Consulter la figure 8. 2. Soulever l’ensemble moteur/ventilateur hors de l’appareil de chauffage. Fig. 8 motor -- enlever les vis et le métal sangle obtenir le moteur à son mont. -- position le moteur entre les t...
Page 43
Il y a deux commutateurs auto de limite de réglant sur cet appareil de chauffage. L'un est localisé sur la plaque de brûleur. L'autre est localisé sur le dessous de la chambre de combustion. Ou coupera le pouvoir à la soupape de contrôle de gaz si l'appareil de chauffage devrait surchauffer. Enlever...
Page 44
Directives de entrentien 1. Utiliser une petite brosse métallique, une portée en bas le baril de l'appareil de chauffage et brosse l'électrode d'igniter. N'impor te enlever lequel développe. 2. Régulièrement vérifier l'écart. L'écart devrait être 4,8 mm selon fig. 15. . Fig. 14 fig. 15 enlevement 1....
Page 45
14 17 thermostat vis thermostat detecteur de temperature commande de l’allumage 1. Débrancher le faisceau de fils de la lampe del de la carte de circuits imprimés, le cas échéant. 2. Enlever les vis et les écrous retenant la commande à l a p a r t i e l a t é r a l e d e l a b a s e d e l ’ a p p a ...
Page 46
Verification de la pression de gaz ■ ce qui suit, décrit les procédures habituelles à respecter au moment d’effectuer une vérification de la pression de gaz. ■ consulter la fiche signalétique sur l’appareil ou la page 4 du présent manuel afin de connaître les niveaux de pression spécifiques requis p...
Page 47
Il faut lire cette toute cette section avant de commancer une procedure de depannage. Ce guide de dépannage est fourni afin d’indiquer les procédures à suivre afin de d’identifier et régler les problèmes de l’appareil. Ce guide est destiné à être employé uniquement par un(e) technicien (ne) qualifiÉ...
Page 48
SÉquence de dÉfaillance d’allumage: - la tentative d’allumage dure environ dix (10) secondes. - si le module de contrôle d’allumage ne détecte pas une flamme pendant la séquence de tentatives d’allumage, le module passe en mode vérouillage de sécurité (le voyant lumineux émet trois clignotements). -...
Page 49
App areil de chauff age tradesman ul tra l e voyant l.E.D. Reste allumé f onctionnement normal 21 probl ème: lampe rouge éteinte oui oui l’appareil de chauf fage s’allume-t-il? La lam pe del est déf ectueuse r e m placer la lam pe del est-ce la bonne tension q ui aliment e le cor don d’alimentation ...
Page 50
22 problème l’obturat eur est-il cour t-cir cuité? (ef fectuer un t est de continuité sur l’obturat eur dans les positions ouv er te et f ermée.) oui si l’obturat eur com por te une bret elle, enle v er la bret elle et ef fectuer le t est de nouv eau. Si l’obturat eur est cour t-cir cuité, rem place...
Page 51
.Deux fois cela indique une défaillance de l’obturateur au niveau du ventilateur (le clignotement commence 90 secondes après le début du problème). Les contacts de l'obturat eur se ferment-ils? Ef fectuer un test de continuité. Éliminer les saletés, rem placer le v entilat eur . Le v entilat eur est...
Page 52
24 trois fois cela indique une défaillance de l’allumage. La commande d’allumage se trouve en mode verrouillé de sécurité. Est-ce le bon carburant q ui aliment e l’appareil de chauf fage? Brancher l'appareil àune sour ce de combustible appr oprié. Ouvrir t out es les v alv esde gaz manuelles. L’appa...
Page 53
Cinc fois si le module de commande ne se réinitialise pas, rem placez-le (déf aut int erne). Si le module se réinitialise, f ait es appel à un électricien q ualif ié pour vérif ier la sour ce d’alimentation et dét ect er t out pr oblème de q ualité du courant. (fréq uence, bruit de ligne, point es s...
Page 54
26 le moteur du ventilateur ne fonctionne pas.L’appareil de chauffage ne s’allume pas. Est-ce la bonne tension q ui aliment e l’appareil de chauf fage? Aliment er l’appareil de chauf fage a v ec la t ension adéq uat e. Vérif ierle disjonct eur et les rallonges électriq ues. Non le thermostat est-il ...
Page 55
27 le ventilateur fonctionne, mais l’appareil de chauffage ne s’allume pas. Les contacts de l’obturat eur se f erment-ils? Ouvrir les v alv es d’alimentation en gaz ef fectuer un t est de continuité sur l’obturat eur . S’assurer q ue le bras de l’obturat eur n’est pas coincé. Réparer ou rem placer l...
Page 56
Diagramme des circuits électriques et diagramme en escalier 28 white black case ground motor solenoid gnd ground mv valve solenoid burner ground direct sense igniter ground direct spark ignition control thermostat valve mv electrical ladder diagram if any of the original wires as supplied with the h...
Page 57
Fonction des composantes de l’appareil de chauffage obturateur d’air dispositif de sécurité utilisé pour réguler adéquatement l’afflux d’air avant l’ouverture de la valve de gaz. Interrupteur de limites supérieures mécanisme de sureté à même le système de contrôle qui court-circuite le courant à une...
Page 58
30 identification des composantes illustration des composantes.
Page 59
31 liste des piÈces numéro de pièce tradesman 170 tradesman 170 item description ultra 1a régulateur avec p.O.L. (gaz propane) 28276 1b régulateur (gaz naturel) 29680 2 boyau, rigide et pivotant, 9.5 mm. × 4.57 m., gaz propane 22278 boyau, rigide et pivotant, 12.7 mm. × 4.57 m., gaz naturel (accesso...
Page 60
32 contactez votre détaillant autorisé l.B.White pour tout appel de ser vice ou pour commander des pièces de remplacement. Vous pouvez communiquer avec l.B. White co. Inc. Au 1-800-345-7200. Assurez-vous d'avoir en main au moment de l'appel, le numéro de modèle et de configuration de votre appareil....