La Crosse WS-2315AL Operation Manual

Manual is about: Professional Remote Weather Station

Summary of WS-2315AL

  • Page 1

    Operation manual professional remote weather station table of contents page 1. Introduction. ................................................................................... 2 2. Intended use. ................................................................................. 2 weather station. ......

  • Page 2

    Features of the base station: • receives and displays the wwvb radio controlled time and date • display of extensive weather data, in all cases with programmable alarm functions for certain weather conditions as well as records of all minimum and maximum values along with time and date of their reco...

  • Page 3

    4. Packaged contents before setting up, carefully unpack the contents onto a table or flat surface and check that the following are complete: item: consisting of: fittings: illustration: base station • main unit • ad/dc 120v power adaptor - optional use (included) thermo- hygro sensor • main unit • ...

  • Page 4

    Setting up using batteries: important: to avoid operating problems, please take note of battery polar- ity if inserting any batteries 1) pull away the rain cover of the thermo-hygro sensor to reveal the three sockets (for the wind sensor, rain sensor and the base station) 2) connect the attached cab...

  • Page 5

    1. Low battery indicator 2. Wwvb radio controlled time icon 3. Date display 4. Time zone display 5. Date, seconds, alarm time and time zone 6. Alarm icon 7. Weather forecast icons 8. Weather tendency indicator 9. Pressure alarm display 10. Hpa/inhg air pressure unit 11. Pressure units (relative or a...

  • Page 6

    8. Function test once the weather station is powered up, perform a function test by checking that the weather data is received. To do this, press the display, pres- sure or wind keys to toggle through the relevant lcd sections: 1) indoor temperature and humidity 2) outdoor temperature and humidity 3...

  • Page 7

    Mounting the rain sensor for accurate results, the rain sensor should be securely mounted onto a hori- zontal surface about 2-3ft above the ground and in an open area away from trees or other coverings where rainfall may be reduced causing inaccurate readings. When securing into place, check that ra...

  • Page 8

    Do not remove batteries or unplug the ac adaptor of the base station other- wise all 175 sets of recorded weather history data for transferring to the pc will be lost (for full details of pc use, please see pc user manual in the enclosed heavy weather cd-rom). However if you wish to make a full rese...

  • Page 9

    Sunny rainy cloudy weather forecasting (lcd section 1) the three weather icons sunny, cloudy and rainy represent the weather forecasting. There are also two weather tendency indicators to show the air pressure tendency either side of the weather icons. Notes to inhg sensitivity setting for weather f...

  • Page 10

    12. Operation keys the base station has 8 keys for easy operation. Please refer to the following table for use and function of each key: further descriptions of the key func- tions with regard to their immediate range of application can be found in the programming modes: set - key - in normal mode t...

  • Page 11

    13. Basic programming modes manual setting modes the manual setting mode allows the user to change several basic settings, which is done by accessing one mode after the other simply by pressing the set key. After the final mode, or if no key is pressed for 30 seconds, the manual setting returns to t...

  • Page 12

    The first case is rainfall total, which has neither maximum nor minimum records since it will show only the total rainfall. Pressing the minus (-) key will reset the rainfall total value to zero and the time recording to cur- rent time. The second case is rainfall 24h or 1h, which records maximum ra...

  • Page 13

    3) press and hold the set key to enter the indoor humidity high setting val- ues (% digits will start flashing) and set the desired indoor humidity high by using the plus (+) or minus (-) keys 4) press alarm key to confirm and press the min/max key to return to the normal display mode or press the a...

  • Page 14

    Pressure high alarm and low alarm setting 1) press the alarm key to enter the normal time alarm 2) continue to press the alarm key until you reach the pressure high alarm set mode 3) press and hold the set key to enter the pressure setting values (digits will start flashing) and set the desired pres...

  • Page 15

    When a set weather alarm condition has been activated, that particular alarm will sound and flash for approximately 2 minutes but will continue to flash until weather conditions have become more steady. Weather alarms the weather alarms are settable for when certain weather conditions are met accord...

  • Page 16

    For best results, do not to add more than 32ft of extension cable from item to item onto the existing cable lengths as this may reduce reception levels. Again, reception and interference levels will greatly depend on the surrounding environment at your point of mounting. Note: it is important to kee...

  • Page 17

    20. Transmission range the transmission distance from the thermo-hygro sensor to the base station in open space under optimum conditions is 100ft. Although the signal transmis- sion may travel though solid surfaces or objects, the following points should be avoided if possible: • high frequency inte...

  • Page 18

    Resolution : 1% measuring range air pressure : 8.85 inhg to 32.45 inhg (standard air pressure at an altitude of 30,000 ft is around 8.85 inhg) resolution . 0.01 inhg relative humidity checking interval : every 30 seconds alarm duration : 2 minutes (approx.) power consumption base station batteries :...