La Crosse WS-7015 Operation Manual

Manual is about: Professional Remote Weather Station

Summary of WS-7015

  • Page 1

    Operation manual professional remote weather station ws-7015 this operation manual is part of this product and must stay with it. It contains important notes on setup and operation. Please keep that in mind when handing this product over to any third party. A table of contents can be found on page 2...

  • Page 2

    Table of contents pages 1. Introduction……………………………………………………………. 26 2. Intended use…………………………………………………………… 26 3. Safety notes……………………………………………………………. 28 4. Product description…………………………………………………... 28-29 5. Shipment contents…………………………………………………… 30 6. Description of measuring devices…………………………………. 30-...

  • Page 3

    - calculation and display of the windchill equivalent temperature (perceived temperature). - dew points, which are separately computed for every one of the 9 temperature/humidity sensors. - air pressure, selectable in inhg or hpa. - air pressure tendency (constant, increasing, strongly increasing, d...

  • Page 4

    South north solar cell magnet mast mounting example of remote wind sensor to a mast this addressing is only necessary if – within the sensor’s transmission range (up to 330 ft (100 m)) – two base stations with respectively assigned indoor sensors need to be operated (base station 1 showing the data ...

  • Page 5

    Generally displayed in the display section in the upper left part of the lcd. After insertion of the batteries the sensor is immediately operable. Remote outdoor sensor the mounting of the sensor should take place anywhere to the west or north since temperatures in meteorology usually are measured i...

  • Page 6

    Important note! In order to unambiguously assign the sensor data the base station should only be put into operation after all sensors have been operating for at least 10 minutes. This point is important since all sensors will at first work in a test mode for up to 10 minutes after the supply power h...

  • Page 7

    9. Display overview note! Unlike the real display the following illustration shows every display combination possible in order to give a description of their appearance. 1. Temperature indoor sensor and indoor/outdoor sensor respectively in degree fahenreit or celsius 2. Current indoor measurement: ...

  • Page 8

    Rain pressing of the "rain" key successively leads to the display of the rain volume of the last hour (interval between the 30 th minute and the 30 th minute of the respective hour), the rain volume of the last 24 hours (interval between 7.30h and 7.30h of the respective day) and the total rain volu...

  • Page 9

    Sensor selection the "sensor" key allows in all operating modes of the weather station the selection of the outdoor temperature/humidity sensors. The selected sensor will in the "sensor“ display section be displayed with its assigned identification number. Outdoor in normal operating mode the outdoo...

  • Page 10

    Caution! Fast pouring will corrupt the measuring results! Pour the water so slow into the funnel, that there is no slack water in the funnel at any time. Recommendation! In order for the water not to run too fast into the funnel, thus causing a faulty calibration, place a small cup made of synthetic...

  • Page 11

    Change of address is only required if two neighbouring wind sensors or rain volume sensors are placed within the reception range of the base station. The base address of the wind sensor and the rain volume sensor can only exclusively be changed by the manufacturer, thus requiring the units to be shi...

  • Page 12

    Furthermore most of these devices allow the change to an interference-free frequency. Such measures will effectivelly overcome interferences. Remote sensor does interfere with other devices in the 433mhz range. The transmissions of the remote outdoor sensor can temporarily (for about 200 ms every 3 ...