Mascot ST Outdoor Cover Kit for Outdoor Installation
Page 2 of 4
5
Vent Termination Clearances
(CSA B149.1)
opening
meter / regulator assembly
Table 6 - Vent Termination Clearances
NOTE: For clearances not specified in ANSI Z223.1/NFPA 54 or CAN/CSA B149.1, use clearances in accordance with local installation codes
and the requirements of the gas supplier.
*Clearance to opposite wall is 24 in.
1
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings that serves both
dwellings.
2
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath floor.
LP-592 Rev.
1.20.16
Description
US
(ANSI Z223.1/NFPA 54)
CANADA
A
Clearance above grade, veranda, porch, deck,
or balcony
12 in.
B
Clearance to window or door that may be
opened
4 ft. below or to side of
opening; 1 ft. above
3 ft.
C
Clearance to permanently closed window
*
D
Vertical clearance to ventilated soffit located above
the terminal within a horizontal distance of 2 feet
from the center line of the terminal
*
E
Clearance to unventilated soffit
*
F
Clearance to outside corner
*
G
Clearance to inside corner
*
H
Clearance to each side of center line
extended above meter / regulator assembly
*
3 ft. with a height 15 ft. above
I
Clearance to service regulator vent outlet
*
3 ft.
J
Clearance to non-mechanical air supply inlet to
building or the combustion air inlet to any other
appliance
4 ft. below or to side of
opening; 1 ft. above
opening
3 ft.
K
Clearance to a mechanical air supply inlet
3 ft. above if within 10 ft.
horizontally
6 ft.
L
Clearance above paved sidewalk or driveway
*
7 ft.
1
M
Clearance under veranda, porch, deck, or
balcony
*
1 ft.
2
• Outdoor Installation Area Operating Conditions Ensure ambient
temperatures are higher than 32°F / 0°C and lower than 104°F / 40°C.
• Prevent the air from becoming contaminated by the products,
places, and conditions listed in the water heater installation manual.
• Avoid continuously high levels of humidity.
Check for nearby connections to System water piping, Venting
connections, Gas supply piping, Electrical power, and the
Condensate Drain.
Check area around heater. Remove any combustible
materials, gasoline, and other flammable liquids.
Clean and flush system when re-installing a heater.
If the heater is to replace an existing heater, check for and
correct any existing system problems, such as:
• System leaks.
• Location that could cause the system and heater to freeze and leak.
• Incorrectly sized expansion tank.