Lab 12 Integre4 Owner's Manual - page 9
LAB12 integre4 Audiophile integrated amplifier
Connections
Main connections
Connect a High Grade Power cable to the IEC input and to your wall socket. Make sure that your
wall socket provides a good ground before connecting the power cable. You can supply 230 to 240
Volts AC (50Hz). (Every integre4 is tuned and calibrated using the LAB12 Knack Power Cable)
Connect an analog source
Connect any line level analog source to any of the five input pairs. We suggest to use high quality,
shielded interconnect cables.
Connect your Speakers
Connect your speakers to the additional output of integre4. Make sure about the phase and
polarity of speakers, always connect ’plus’ (red) bind of integre4 to ’plus’ (red) bind of
speaker and respectively the black one. You can connect any speakers with impedance from
4 to 16 ohm.
For the safety of your equipment
! Make sure that all of your equipment is turned off before any
connection.
! Never turn on integre4 without connected speakers on it. It is
possible to damage tubes or even output transformers.
! After turning off your amplifier allow at least 10 minutes before
turning it back ON.