Lab.gruppen fP Series FP 3400 User Manual

Other manuals for fP Series FP 3400: Brochure, Specifications
Manual is about: Lab.gruppen fP Series FP 3400: User Guide

Summary of fP Series FP 3400

  • Page 1

    Ñm=pqmm= rpbo=j^kr^i= =.

  • Page 2: N= `lkqbkqp=

    N= `lkqbkqp= 1 contents .......................................................................................................................................1 2 approvals...................................................................................................................................

  • Page 3: O= =^mmols^ip=

    9.1.5 ac mains voltage protection ............................................................................................16 9.1.6 dc protection ...................................................................................................................16 10 maintenance......................

  • Page 4

    8. Always operate the unit with the chassis ground wire connected to the electrical safety earth. Do not defeat the safety purpose of a grounding-type plug. A grounding type plug has two pins and a third grounding prong. The third prong is provided for your safety. If the provided plug does not fit ...

  • Page 5: Q= Fkqolar`qflk=

    • increase the separation between the equipment and receiver. • connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • check if the affected unit complies with the emc limits for immunity, (ce-labelled). If not, address the problem with the manufa...

  • Page 6

    This indicator illuminates if signals above 12 khz are continuously present at full power at the output terminals. If this occurs the input signal is muted, and the process cycles until the vhf signal is no longer present. (see page 16 ) 5. Clip/limit indicator this indicator signals if the amplifie...

  • Page 7: R= Ob^o=M^kbi=Cb^qrobp=

    Three of the switches in the dip switch selects the maximum gain of the channel to be either 20, 23, 26, 29, 32, 35, 38 or 41db. (see page 6 ) 9. Ac power cable r= ob^o=m^kbi=cb^qrobp= before turning the amplifier on please read the following sections to make sure that the unit is set up properly fo...

  • Page 8

    Rknkp= léíáçåë= as the dip switch is recessed, one may put a sticker across the bay to prevent from unauthorized changes. Another option is to completely remove the dip switch. This should be done by authorized service personnel only! It corresponds to all switches set to “off”, i.E. 32db gain and s...

  • Page 9

    Rkpkq= _êáÇÖÉ=ãçåç=ãçÇÉ= the bridge mono mode is used to deliver both channels' power to a single load. The nominal impedance of the load must be more than 3 ohms. Set the link switches to the “on” position and use one of the input connectors. You may use the remaining input connectors to carry the ...

  • Page 10

    Mls tm settings can be different for each channel, and a variety of combinations can be achieved – see table 2. Table 2 provides the simplest way to find the best mls tm settings for your application. There is no risk to damage the amplifier since it is very well protected (even down to 0.3 ohms). T...

  • Page 11: S= Fkpq^ii^qflk=

    Rkqko= jip=íÉÅÜåçäçÖó=Ó=íÜÉ=Ä~ÅâÖêçìåÇ= rkqkp= qÜÉ=éêçÄäÉã= assume that a power amplifier can deliver 1000 watts into 8 ohms, and it should be able to run also into 2 ohms. Theoretically, and according to the physical laws, it should be able to deliver 4000 watts into 2 ohms. Very few professional p...

  • Page 12

    Skp= léÉê~íáåÖ=îçäí~ÖÉ= warning! A label just below the mains cable on the rear of the amplifier indicates the ac mains voltage for which the amplifier is wired. Connect the power cable only to the ac source referred to on the label. The warranty will not cover damage caused by connecting to the wro...

  • Page 13

    Second, the maximum expected average current under worst case program material, which is 1/3 of full power according to the ftc standard. At this level the music will be in the state of constant clip and is therefore the highest power level one can obtain without completely obliterating the program....

  • Page 14: T= `lkkb`qflkp=

    T= `lkkb`qflkp= tkn= fåéìí=ÅçååÉÅíáçåë= tknkn= _~ä~åÅÉÇ=áåéìíë= the xlr input connectors are electronically balanced, and wired according to the iec 268 (pin 2 = “hot”), and wired in the following way: pin 1 ground/shield pin 2 hot (+) pin 3 cold (-) figure 4: xlr input connector figure 5: xlr balan...

  • Page 15: U= Lmbo^qflk=

    Tko= `çååÉÅíáåÖ=ëéÉ~âÉêë= speaker connections are made via the two neutrik® nl4fc speakon connectors. The speakon connector is designed for high power speaker connections. It assures the correct polarity, it locks in place and prevents from shock hazard. They are wired in the following manner: the r...

  • Page 16: V= Molqb`qflk=Cb^qrobp=

    Ukp= fåéìí=~ííÉåì~íçêë= the two input level attenuators on the front panel adjust the signal level for their respective amplifier channel in all modes. They are calibrated in db to assist the setup of active loudspeaker systems, or to cut down unwanted noise from the input signal. In bridge mode bot...

  • Page 17

    Vknko= qÜÉêã~ä=éêçíÉÅíáçå= if the amplifier is driven very hard into a low impedance load, the cooling fans will run at high speed. If the causing conditions continue, the “temp” temperature indicator(s) will illuminate indicating that the amplifier is about to go into thermal shutdown. After approx...

  • Page 18: Nm=J^fkqbk^k`b=

    Nm=j^fkqbk^k`b= under normal use the amplifier should provide years of trouble-free service. The only user maintenance required by the user is to vacuum the front grille periodically. In some extreme cases it may be necessary for authorized service personnel to clean the inside of the amplifier. The...

  • Page 19: Nn=Pmb`fcf`^qflkp=

    Nn=pmb`fcf`^qflkp= i~ÄkÖêìééÉå== = = = = = ======================== nu rëÉê=j~åì~ä===Ñm=pqmm======sÉêëáçå=nkn========ommpjnmjmo=.

  • Page 20: No=T^oo^kqv=

    No=t^oo^kqv= general this product is manufactured by lab.Gruppen and is warranted to be free from defects in components and factory workmanship under normal use and service for a period of three (3) years from the date of original purchase from an authorised lab.Gruppen dealer. When failing to perfo...