Lab.gruppen LUCIA 120/1-70 Operation Manual

Manual is about: Lucia Series Compact installation amplifiers

Summary of LUCIA 120/1-70

  • Page 1

    Lucia® compact installation amplifiers operation manual rev. 1.2.0 item no. Om–lucia.

  • Page 2

    1. Important safety instructions 2 lucia operation manual rev 1.2.0 1. Important safety instructions and the safety instructions. 1. Read these instructions. 2. Keep these instructions 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry...

  • Page 3

    Lucia operation manual rev 1.2.0 3 3.2 warnings apparatus to rain or moisture. Français: pour réduire les risques d’incendie ou de choc électrique, n’exposez pas l’appareil à la pluie ou à l’humidité. Do not expose this system/apparatus to dripping or splashing are placed on the apparatus. Français ...

  • Page 4

    4. Table of contents 4 lucia operation manual rev 1.2.0 4. Table of contents 1. Important safety instructions 2 2. Approvals 2 3. Warnings 2 3.1 explanation of warning symbols 2 3.2 warnings 3 3.3 user responsibility 3 5. Introduction 6 5.1. Welcome 6 5.2. Features (all lucia models) 6 5.3. Addition...

  • Page 5

    4. Table of contents lucia operation manual rev 1.2.0 5 14. Lucia application browser 14 14.1. Introduction 14 14.2. Software download and installation 14 14.3. Overview 15 14.4. Factory presets 15 16 16 16 14.5.2.1. Input block 17 14.5.2.2. Matrix block 17 14.5.2.3. Output block 18 14.5.2.4. Contro...

  • Page 6

    5. Introduction 6 lucia operation manual rev 1.2.0 5. Introduction 5.1. Welcome outstanding performance, reliable operation and a long service life in any type of commercial sound or general av application. Control and i/o are conveniently placed exactly where they are needed. In many av application...

  • Page 7

    6. Unpacking and visual checks lucia operation manual rev 1.2.0 7 6. Unpacking and visual checks condition. If any damage is discovered, please notify the shipping carrier immediately. Save the packing materials for the carrier’s inspection and for any future shipping. 7. Installation 7.1. Wall moun...

  • Page 8

    8. Cooling and fan operation 8 lucia operation manual rev 1.2.0 8. Cooling and fan operation fan mode description sustainable average output power loudspeaker spl extra rel. 1 w sensitivity* distance at which you get the 1 w spl** fan noise at 1 m distance low spl applications with proper ventilatio...

  • Page 9

    11. Front panel lucia operation manual rev 1.2.0 9 11. Front panel 1 standby/on led indicator the speaker outputs are muted. See “protection mode” in section 13.3. 2 signal present/limit/clip indicators – a three-color led illuminates to provide channel status information as follows: green – signal ...

  • Page 10

    12. Rear panel 10 lucia operation manual rev 1.2.0 12. Rear panel 1 balanced audio inputs (1 & 2) – connect balanced inputs using 3-pole euroblock connectors. Correct polarity (+, -) and ground terminations are shown on the rear panel. Observe polarity to avoid low frequency cancellation loss, espec...

  • Page 11

    12. Rear panel lucia operation manual rev 1.2.0 11 1 balanced audio inputs (1 & 2) – connect balanced inputs using 3-pole euroblock connectors. Correct polarity (+, -) and ground terminations are shown on the rear panel. 2 unbalanced audio inputs (1 & 2) – connect unbalanced inputs (e.G. Local video...

  • Page 12

    13. Set-up and operation 12 lucia operation manual rev 1.2.0 13. Set-up and operation 13.1. Auto standby / power-up urn on automatically when ac power is connected to the unit; it will go into standby mode if no signal is present at any input for 20 minutes. When in standby, the reset threshold (-54...

  • Page 13

    13. Set-up and operation lucia operation manual rev 1.2.0 13 13.3. Gpio configuration: mono high-impedance models the default functionality is as described below for general purpose inputs and output (gpio). Remote volume control – connect a remote volume control potentiometer to ground, gpi1 and vc...

  • Page 14

    13. Lucia application browser 14 lucia operation manual rev 1.2.0 13.4. Protection mode mode automatically. Important – protection mode often results from excessive operating levels, improper load conditions or 14. Lucia application browser 14.1. Introduction 14.2. Software download and installation...

  • Page 15

    14. Lucia application browser lucia operation manual rev 1.2.0 15 14.3. Overview one view. The window is divided into three columns: application selector column – the left-hand column lists all application presets currently available for downloading to lucia devices. When created, new user presets a...

  • Page 16

    14. Lucia application browser 16 lucia operation manual rev 1.2.0 14.5. Application presets: selection and custom configuration 14.5.1. Configuration in application view select the factory application or existing user application that is closest to the requirements of the new application. If necessa...

  • Page 17

    14. Lucia application browser lucia operation manual rev 1.2.0 17 14.5.2.1. Input block speech input (vocal 100 hz cut). A third option (custom…) allows user configuration of the 4 eq sections on each input. Select the option appropriate for your application. 14.5.2.2. Matrix block manual routing – ...

  • Page 18

    14. Lucia application browser 18 lucia operation manual rev 1.2.0 14.5.2.3. Output block the connected loudspeakers. Factory presets – presets are provided with output equalization optimized for many tannoy loudspeakers. Custom user presets – to create a custom output preset, scroll to the bottom of...

  • Page 19

    14. Lucia application browser lucia operation manual rev 1.2.0 19 be accessible.) adlc (automatic dynamic loudness contouring) – adlc is a sophisticated, dsp-controlled function that maintains optimum sound balance regardless of listening level. Adlc may be enabled or disabled using the radio button...

  • Page 20

    14. Lucia application browser 20 lucia operation manual rev 1.2.0 14.6. Saving and storing custom applications 14.6.1. Saving applications lick on the save button. A dialog window will ion of the application preset. Click on the save the new custom application will appear at the top of the list in t...

  • Page 21

    14. Lucia application browser lucia operation manual rev 1.2.0 21 press the program button essfully transferred to the device. The dialog also shows an option to enable synchronization. If you want to further edit parameters in real time, click the button and then click “ok.” (see online mode follow...

  • Page 22

    15.3. Default configuration for lucia 70v models 15. Appendices 22 lucia operation manual rev 1.2.0 15. Appendices 15.1. Default configuration for lucia base models in 1 rc a ba l +6 db 1 2 gpi1 gpi2 in 2 ba l rc a +6 db spk 1 spk 2 15.2. Default configuration for lucia m models in 1 rc a ba l +6 db...

  • Page 23

    15. Appendices lucia operation manual rev 1.2.0 23 a resistor ladder selector can be used to perform selection of up to 4 different alternatives. The total impedance should be between 1k and 100k ohm and one way to do it is as illustrated below (this is also how the lab.Gruppen accessory is made). S...

  • Page 24

    15. Appendices lucia operation manual rev 1.2.0 25 15. Appendices 24 lucia operation manual rev 1.2.0 15.5. Thermal dissipation lucia 60/2 level load output power mains watt *1) thermal dissipation vac iac in out dissipated btu/hr kcal/hr standby w. Remote power off. 230 0,032 0,88 0 1 3 1 120 0,027...

  • Page 25

    15. Appendices lucia operation manual rev 1.2.0 25 15. Appendices 22 lucia operation manual rev 1.1.0 15.4. Thermal dissipation lucia 120/2 level load output power mains voltage line current watt *1) thermal dissipation vac iac in out dissi- pated btu/hr kcal/hr standby w. Remote power off. 230 0.03...

  • Page 26

    15. Appendices 26 lucia operation manual rev 1.2.0 lucia 120/1-70 level load output power mains watt *1) thermal dissipation vac iac in out dissipated btu/hr kcal/hr standby w. Remote power off. 230 0,032 0,88 0 1 3 1 120 0,027 0,77 0 1 3 1 100 0,028 0,76 0 1 3 1 power on, idling 230 0,12 11,9 0 12 ...

  • Page 27

    15. Appendices 22 lucia operation manual rev 1.1.0 15.4. Thermal dissipation lucia 120/2 level load output power mains voltage line current watt *1) thermal dissipation vac iac in out dissi- pated btu/hr kcal/hr standby w. Remote power off. 230 0.032 0.88 0 1 3 1 120 0.027 0.77 0 1 3 1 100 0.028 0.7...

  • Page 28

    15. Appendices 28 lucia operation manual rev 1.2.0 lucia 240/1-70 level load output power mains watt *1) thermal dissipation vac iac in out dissipated btu/hr kcal/hr standby w. Remote power off. 230 0,032 0,88 0 1 3 1 120 0,027 0,77 0 1 3 1 100 0,028 0,76 0 1 3 1 power on, idling 230 0,12 11,9 0 12 ...

  • Page 29

    15. Appendices lucia operation manual rev 1.2.0 29 15.6. Technical specifications general lucia 240/2m lucia 120/2m lucia 60/2m number of powered channels 2 2 2 total output all channels driven 240 w 120 w 60 w max output voltage per channel 1) 43.8 vpeak 31 vpeak 21.9 vpeak max output current per c...

  • Page 30

    15. Appendices 30 lucia operation manual rev 1.2.0 general lucia 240/2 lucia 120/2 lucia 60/2 number of powered channels 2 2 2 total output all channels driven 240 w 120 w 60 w max output voltage per channel 1) 43.8 vpeak 31 vpeak 21.9 vpeak max output current per channel 7.8 arms 5.5 arms 3.9 arms ...

  • Page 31

    15. Appendices lucia operation manual rev 1.2.0 31 general lucia 240/1-70 lucia 120/1-70 lucia 60/1-70 number of powered channels 1 1 1 total output all channels driven 240 w 120 w 60 w max output voltage 100 v peak 100 v peak 100 v peak max output current 7 arms 3.5 arms 1.8 arms performance 70 v 2...

  • Page 32

    16. Faq 32 lucia operation manual rev 1.2.0 16. Faq is the lucia power stage inherently bridged as on e series, thereby allowing asymmetrical loading? To use power on one channel that is not being used on the other, as with lab.Gruppen’s e series. However, the channels are automatically optimized wh...

  • Page 33

    16. Faq 32 lucia operation manual rev 1.2.0 16. Faq is the lucia power stage inherently bridged as on e series, thereby allowing asymmetrical loading? To use power on one channel that is not being used on the other, as with lab.Gruppen’s e series. However, the channels are automatically optimized wh...

  • Page 34

    Lucia tm and auto load sense tm are trademarks of lab.Gruppen ab. All other trademarks remain the property of their respective owners. Copyright © 2015 music group innovation sweden ab. All rights reserved. Labgruppen.Com item no. Om-lucia.