Lacanche LAG 010 CKG General Manual - page 9
INSTALLER’S MANUAL
LAG 010 CKG
Page 9 sur 18– Ft010CKG – US – Date de mise à jour : 26/02/10 - Indice : 01
Adjusting reduced flow of hob burners :
A
fter connection or change of gas, it is crucial to modify this adjustment :
►
R
emove the knob.
►
L
ight the appropriate burner.
►
A
djust to minimum setting.
►
U
se a small screwdriver to set the adjusting screw
E
.
N.B
: Flame is reduced to ¼ of its size in the minimum setting, the burner must remain lit when changing
from maximum setting to minimum setting.
Adjusting the safety devices for each thermocouple of the hob :
I
f the burner goes out, having kept the control knob pushed in for roughly twenty seconds, check that
:
-
T
he magnetic head grip the valve moderately.
-
T
he flame touches the point of thermocouple
F
.
-
T
he thermocouples and magnetic heads are absolutely clean.