Lacanche LAG 010 CKG User manual - Changing Gas
INSTALLER’S MANUAL
Changing Jet :
Remove the jet (see
A
, figure
1
) and replace with the appropriate sized jet (see table 6, appendix 0
(Ø in 1/100 mm).
Adjusting the primary air :
Loosen the screw that secures the air ring
B
/ figure
2
.
Adjust the airflow by moving the adjusting air ring (Charcoal : tabel
7 in appendix 0).
Commissioning (fine tuning) gas burners :
After connection or changing gas type, it is imperative to adjust for a fine tuning :
►
Ignite the burner in MAX. Wait for 10 minutes to reach temperature and then reduce to minimum setting,
and remove the control knob.
►
Using a flathead screwdriver adjust the simmer flame accordingly (see
C
, figure
3
).
Note : Flame is reduced to ¼ of you turn maximum to minimum. Looking for a crisp flame without any
yellow wich does not go out when turned from maximum to minimum.
CHANGING GAS
TYPE
(LAVAROCK LAG 010 CKG)
Lacanche ranges are supplied with the appropriate gas fitting for the gas type specified when the order is
placed. However, the settings must be fine (COMMISIONED) when the cooker is installed.
The cooker is designed to operate with the gases in table
4, appendix 0.
CAUTION : Close the mains gas valve before carrying out any works.
IMPORTANT
In case of use with a gas other than that for which the cooker was initially set up, it is crucial to
replace the injectors and modify the adjustments as defined below.
1
2
3
A
B
C
Adjusting air ring
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 9/17