Lacanche LAG 010 CKG User Manual - page 10
Other manuals for LAG 010 CKG:
User manual, General Manual
of
20
Adjusting reduced flow of hob burners:
After connection or change of gas, it is crucial to modify
this adjustment :
►
Remove the knob.
►
Light the appropriate burner.
►
Adjust to minimum setting.
►
Use a small screwdriver to set the adjusting screw
E
.
Note
: Flame is reduced to
¼
of its size in the minimum
setting, the burner must remain lit when changing
from maximum setting to minimum setting.
Adjusting the safety devices for each thermocouple of the hob:
If the burner goes out, having kept the control knob pushed in for roughly twenty seconds, check that
:
- The magnetic head grips the valve moderately.
- The flame touches the point of thermocouple
F
.
- The thermocouples and magnetic head connections are absolutely clean.
Page 10 of 20– LAG010CKG – US