Ladner Tomtone Deluxe Owner's Manual - Rear Panel
Tomtone Deluxe Guitar Amplifier Owner’s Manual
PAGE 6
Rear Panel
1 – FUSE- This is the line fuse for the amplifier. The proper fuse should be installed
based on the line voltage to which the unit is attached. The table below shows the
proper fuse to be used with the selected line voltage.
NOTE: Failure to install the
proper fuse based on the line voltage selected can result in personal injury, fire,
damage to the amplifier or other nasty things too numerous to mention here.
2 - AC POWER – an IEC standard removable power cable. The unit should only be
plugged into a proper AC Line Voltage as indicated by the selection of the switch
(see #3 line voltage selection) of the IEC connector
3– Line Voltage Selector – Selects between 120 VAC operation and 230 VAC
operation.
NOTE: Proper fuse MUST be installed.
4 – BIAS Adjustment – These adjustment controls the BIAS of the output amplifier.
This adjustment should only be used by qualified service personnel.
5 – BIAS Test Points – Used in conjunction with the BIAS Adjustment. Voltage present
on these test points represent the current flowing through the output tubes.
6 – FOOTSWITCH – Connection for the channel selection footswitch and EFX loop on
and off, a standard TRS or Tip Ring Sleeve cable is required.
NOTE:
The front panel
selector switch is disabled when the footswitch is plugged into this jack.
A faulty
footswitch or flaky cable can cause the amp to default to the Overdrive Channel!!!
LINE VOLTAGE
FREQ
FUSE
FUSE TYPE
120 VAC
50/60 Hz
2 A
AGC
230 VAC
50/60 Hz
1.25 A
AGC