Lagoon 620 Owner's Manual - page 23
23
1
2
3
4
5
6
6
E Q U I P M E N T
4.3.2
.
110 V - 220 V Electrical system
Some boats are fi tted with a 110 V or 220 V circuit
(in their standard version or as an option according
to the model).
It is necessary to observe the following rules in
order to avoid electric shocks and fi re:
Never work on the live electric circuit.
Connect the boat shore supply cable in the boat
before plugging it to the shore supply socket.
Never let the end of the boat shore supply cable
fall into the water.
When the shore supply socket is plugged, there
could be a diff erence between the "earth" on the
boat and the one of the power grid. This could
create a danger of electrical cross - currents and
therefore electrocution (particularly for nearby
swimmers).
Turn off the shore power with the cut off device
fi tted on board before plugging or unplugging
the boat shore supply cable.
Unplug the boat shore supply cable fi rst on the
shore side.
If the reverse polarity indicator is on,
immediately unplug the cable. Solve the
polarity problem before using the electrical
system of the boat.
Thoroughly close the shore socket cover.
Do not modify the connections of the boat / shore
supply cable; only use compatible connections.
Do not modify the boat electrical system nor
the relevant diagrams. It is necessary that any
modifi cation and maintenance are carried out by
a technician skilled in marine electricity. Have the
system checked at least twice a year.
Unplug the vessel's supply when not in use, in
order to avoid any fi re risk.
Connect the electrical appliances metallic covers
or boxes to the protective conductor of the boat
(green conductor with yellow stripes).
Only use electrical devices with double insulation
or earth.
Please note that live wires are blue, neutral wires
are brown and earth wires are green and yellow.
1 - 110 V - 220 V protection panel.
2 - 110 V - 220 V selection panel.
3 - Starting / stop control of the converter.
4 - Starting / stop control of the watermaker (optional).
5 - Starting / stop control of the generator.
6 - Household appliances circuit breakers.