- DL manuals
- Lake People
- Media Converter
- ADC F444
- User Manual
Lake People ADC F444 User Manual
1
BEDIENUNGSANLEITUNG
USER´s MANUAL
ADC F444
ADDAC F446
DAC F466
Revision 2 IV/2007
AVAILABLE MODELS
ADC F466-S:
2-ch Analog-Digital Converter
ADC F466-D:
4-ch Analog-Digital Converter
ADDAC F446:
2/2-ch A/D – D/A Converter
DAC F466-S:
2-ch Digital-Analog Converter
DAC F466-D:
4-ch Digital-Analog Converter
Inhalt / Content
Seite / Page
Allgemeine Sicherheitshinweise 2
Das Erde / Masse Konzept
3
Anschluss / Steckerbelegung
4
Bedienungsanleitung 6
General Safety Instructions 14
The Earth / Grounding Concept 15
Connection / Connectors 16
User´s Manual 18
Technische Daten / Technical Specifications 26
PCB Layout / Jumper settings
27
Konformitätserklärung / Conformity Statement
28
development and
manufacturing of
audio electronic
Turmstrasse 7a
78467 Konstanz
GERMANY
Tel. +49 (0) 7531 73678
Fax +49 (0) 7531 74998
www.lake-people.de
Summary of ADC F444
Page 1
1 bedienungsanleitung user´s manual adc f444 addac f446 dac f466 revision 2 iv/2007 available models adc f466-s: 2-ch analog-digital converter adc f466-d: 4-ch analog-digital converter addac f446: 2/2-ch a/d – d/a converter dac f466-s: 2-ch digital-analog converter dac f466-d: 4-ch digital-analog co...
Page 2
2 allgemeine sicherheitshinweise warnung bitte lesen sie die folgenden sicherheitshinweise: wasser, flüssigkeiten, feuchtigkeit: das gerät soll nicht in der nähe von wasser- oder flüssigkeitsquellen benutzt werden. Das gerät soll nicht in bereichen grosser feuchtigkeit betrieben werden. Achten sie d...
Page 3
3 das erde / masse konzept general ground-lift jumper (von aussen zugänglich): ab werk ist dieser jumper auf gnd/ground gesetzt. Der interne masse-bezugspunkt kann auf der rückseite des gerätes über den jumper von ground auf lift gelegt werden. Die verbindung zwischen internem masse-bezugspunkt und ...
Page 4
4 anschluss / steckerbelegung für digitale signale s o u rce 1 2 3 hot cold shield x symmetrisches kabel (signal) an trafosymmetrischen eingang balanced incoming signal xlr male plug shield / abschirmung = signalmasse = pin 1 hot / + phase = pin 2 cold / - phase = pin 3 das steckergehäuse sollte nic...
Page 5
5 anschluss / steckerbelegung für analoge signale s o ur ce 1 2 3 hot cold shield x symmetrisches kabel (signal) an (trafo)symmetrischen eingang balanced incoming signal xlr male plug shield / abschirmung = signalmasse = pin 1 hot / + phase = pin 2 cold / - phase = pin 3 das steckergehäuse sollte ni...
Page 6
6 allgemeines der lake people wandler f444 / f446 / f466 bestehen aus ein oder zwei a/d und/oder d/a wandlerbaugruppen höchster qualität. A/d wandlerbaugruppen verfügen zusätzlich noch über eine sync-baugruppe. Der a/d teil wandelt ein stereophones analo- ges eingangssignal in ein lineares (pcm) 24 ...
Page 7
7 die externen sync eingÄnge drei verschiedene sync-eingänge befinden sich auf der rückseite des gerätes und sind entsprechend bezeichnet. Sie akzeptieren an den jeweiligen anschlüssen aes/ebu-, aes- id- und wclk-signale. Der aes/ebu eingang ist als xlr-verbinder ausgeführt und entspricht aes 3/11, ...
Page 8
8 - der professional-mode ist eingestellt, wenn die gelbe "pro" led leuchtet: das format des digitalen ausgangswortes der angeschlossenen module wird unabhängig vom sync-signal auf den professional- mode gesetzt. Der mute taster mit dem "mute" taster kann eine stumm- schaltung der an den sync angesc...
Page 9
9 hinweis: der adc f444 kann ein oder zwei adc-modu- le aufnehmen. Die getätigten einstellungen am sync-modul gelten immer für beide adc´s. Wenn zwei adc-module vorhanden sind, sind die digitalen ausgänge beider module block- synchron zueinander. Die analogen eingÄnge die analogen eingänge befinden ...
Page 10
10 das datenwort (professional- oder consumer- format) ist an allen ausgängen gleich, unabhängig von der norm oder bauweise der anschlüsse. Die ausgänge befinden sich auf der rückseite des gehäuses und sind entsprechend bezeichnet: - der symmetrische ausgang ist als xlr- verbinder ausgeführt und ent...
Page 11
11 hinweis: der dac f466 kann ein oder zwei dac module aufnehmen. Die module arbeiten völlig autonom, da sie (bis auf die spannungs- versorgung) getrennt aufgebaut sind. Die digitalen eingÄnge die beiden digitale eingänge befinden sich auf der rückseite des gerätes. Sie akzeptieren digitale daten im...
Page 12
12 key-lock um eine unbeabsichtigte bedienung zu ver- meiden, kann die tastatur jedes dac-moduls verriegelt werden. Gleichzeitiges drücken des "input" tasters für > 2 sekunden aktiviert / deaktiviert den key-lock. Der aktivierte zustand wird über die grüne "key-lock" led angezeigt. Der d/a wandler d...
Page 13
13 die option "digital outputs" Über diese option kann der dac f466 mit digitalen ausgängen ausgestattet werden. An den ausgängen erscheint das als aktiver durchschliff das auf der frontplatte ausge- wählte digitale signal als: - symmetrischer ausgang über xlr, ent- sprechend aes 3-1992, trafosymmet...
Page 14
14 general safety instructions warning for your protection, please read the following: water, liquids, moisture: this appliance should not be used near water or other sources of liquids. Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings....
Page 15
15 the earth / grounding concept general ground-lift jumper (accesible from the rear of the case): ex works this jumper is plugged to gnd/ground position. The internal ground potential, which is normally connected to the external earth reference at this point may be lifted with the aid of this jumpe...
Page 16
16 connection / connectors for digital signals s o urce 1 2 3 hot cold shield x balanced cable (signal) to transformer balanced input balanced incoming signal xlr male plug shield = signal ground = pin 1 hot / + phase = pin 2 cold / - phase = pin 3 the case of the connector should not be wired to th...
Page 17
17 connection / connectors for analog signals s o ur ce 1 2 3 hot cold shield x balanced cable (signal) to (transformer) balanced input balanced incoming signal xlr male plug shield = signal ground = pin 1 hot / + phase = pin 2 cold / - phase = pin 3 the case of the connector should not be wired to ...
Page 18
18 general the lake people converters f444 / f446 / f466 consists of one or two a/d and/or d/a converter modules of highest quality. A/d converts also include a sync module. The a/d part converts a stereophonic analog input signal into a linear (pcm) 24 bit digital output signal with a dynamic range...
Page 19
19 the external sync inputs the sync inputs are located on the rear panel and marked according to their function. They accept aes/ebu (sync) – signals, aes-id (sync)-signals and wclk signals. According to aes 3/11, the aes/ebu input is equipped with an xlr typ socket, transformer balanced with 110 o...
Page 20
20 - the unit is set to consumer mode when the yellow “con” led is lit. The format of the digital outputs of the connected a/d modules is set to consumer format, inde- pendent from a coding of the sync-signal. - the unit is set to professional mode when the yellow “pro” led is lit. The format of the...
Page 21
21 hint: adc f444 may contain one or two a/d mo- dules. The settings of the sync module are valid for both src modules. If two a/d modules are present, their digital outputs are synchronized relative to the sync the analog inputs the analog inputs are situated on the rear panel and equipped with bal...
Page 22
22 the digital outputs the a/d part offers two digital outputs – bal- anced and unbalanced. Independent from their design, data words – professional or consumer - on all outputs are identical. The outputs are situated on the rear panel and marked to their function. - the balanced output is equipped ...
Page 23
23 hint: dac f466 may contain one or two d/a modules. The modules may work totally inde- pendendly from each other as they only share the common power supply. The digital inputs two digital inputs are situated on the rear panel and marked to their function. On both inputs professional or consumer co...
Page 24
24 when the sample rate of the emphasis signal is different to 44.1 khz, wrong conversion of higher frequency analog signals has to be calculated. Key-lock to avoid unwanted operation, the keys of the dac module may be locked. Pushing the “input” button for > 2 seconds will activate / de-activate th...
Page 25
25 the option "digital outputs" as an option dac f466 may be equipped with digital outputs for both d/a modules. Here, the selected input signal is output as an active refreshed signal as follows: - balanced out via xlr, according to aes 3- 1992, transformer balanced, impedance 110 ohms. - coaxial o...
Page 26
26 technical data adc f444 / addac f446 / dac f466 (all measurements a-weighted, 20 hz... 20 khz, 48 khz internal sample rate, referred to digital full scale and +20 dbu analog input/output level) sync module external inputs: 1 x xlr female, transformer balanced, impedance 110 ohms 2 x bnc, unbalanc...
Page 27: A/d-Modul
27 pcb layout and jumper setting modul 1 1 - 2 1 - 2 modul 2 configuration of optional digital out modul ground-lift jumper pin 1 from xlr socket connected to internal ground-plane. (ex works setting) pin 1 from xlr socket lifted. Pin 1 from xlr socket connected to case. . C l g c l g c l g a/d-modu...
Page 28: Konformitätserklärung
28 konformitÄtserklÄrung conformity statement ----------------------------------------------------------------------------- konstanz 26.09.2014, fried reim, geschäftsführer / ceo wir bestätigen hiermit, dass das folgende gerät: bezeichnung: adc f444 addac f446 dac f666 serien nr. : -alle- mit folgen...