    Distributed by pure n natural systems, inc. 1-800-237-9199 www.Purennatural.Com operating and service instructions model la-1000fm (lafc) & la-800h (hepa lafc) manufactured by:.

  • Page 2

    Table of contents introduction 3 3 3 providing clean fresh air energy consumption is lower recirculated air for comfort and savings 3 4-5 5 components of the lafc and hepa lafc how your lafc model works installation instructions important safety instructions equipment needed for installation items s...

  • Page 3

    Owner’s manual introduction your lakeair model lafc is a self-contained ceiling mounted electronic air cleaner. Model hepa lafc uses a high efficiency non-electric media. They are designed for installation in a standard t-bar ceiling in the space occupied by a 2 x 4 drop ceiling panel. Each unit is ...

  • Page 4

    Electronic collection cell thee electronic model lafc uses one large collection cell positioned behind the pre filter screen which collects the majority of the air-borne particles that enter the system. Hepa pad media and carbon afterfilter carbon afterfilter is standard with all lafc units, and is ...

  • Page 5

    Adjustable exhaust grille large adjustable exhaust grille with individu-ally adjustable vanes allows a variable air-flow to be presented to the room according to size and traffic pattern. Safety interlock system located in the channel behind the collecting cell, the micro- switch controlled interloc...

  • Page 6

    Installation instructions it is important to read the following instructions carefully. Damage to the product or to installer and property could re-sult if instructions are not followed. Important safety precautions 1. Do not connect the power source until after the unit is mounted. Shock and/or dam...

  • Page 7

    Installation of the electrical wiring caution: this procedure should only be attempted by persons qualified to install electrical wiring. All wiring must comply with applicable codes and ordinances. 1. Locate a 120v ac, 60 hz (alternative power sources would be used in the case of the lafc 230v unit...

  • Page 8

    General information: application the model lafc should be mounted in the room or area where the air is to be cleaned. Removal of such pollutants as tobacco smoke and pollen from the air in areas like conference rooms, lounges, bingo halls, offices and the like is the goal of the unit. The lafc provi...

  • Page 9

    Maintenance washing the electronic cells and prefilter in order for your lakeair model lafc to maintain peak operating efficiency, the prefilter screen and the electronic cells must be washed regularly. The frequency of this cleaning will depend on the atmosphere in which the units are operating. Re...

  • Page 10

    Lakeair model lafc troubleshooting guide and chart warning!!! The following instructions are intended for qualified service personnel only. Dangerous line voltage circuits are exposed during these procedures. Disconnect power at fuse before servicing the unit. Trouble shooting the lafc can be accomp...

  • Page 11

    Component checks 1. Check fan motor and power source if the fan does not run when the switch is on either in the high or low position, check the voltage supplied to the motor. 1. If the motor does not turn when the proper voltage is supplied to it, check to see that the shaft turns freely. Replace t...

  • Page 12

    Trouble shooting flowchart the following trouble shooting procedure has been designed to speed the serviceman’s work and insure that any malfunction in the electronic air cleaner is quickly and properly repaired. Refer first to flow chart below for an outline of the procedure, and then refer to the ...

  • Page 13

    13 electrical connections energized conductor 115v power wire blue or black wire from power supply in lafc brown or white wire from power supply in lafc green ground wire from power supply in lafc neutral conductor wire green ground wire.

  • Page 14

    Electrical schematic model lafc, 120v, 230v 14 lafc electronic 120v 230v safety interlock micro switch 497576 497567 on/off switch 497612 497612 motor/blower 497602 497609 fuse 497547 497547 indicator lamp 497570 497592 power supply 10079 10179.

  • Page 15

    Part# description qty. Used 10 0 79 complete power supply 120v (electronic only) ( contains 497606 transformer & 497524 voltage quad) 1 101 79 complete power supply 230v (electronic only) (contains 497607 transformer & 497524 voltage quad) 1 10107 complete electronic filter cell (electronic only) 1 ...

  • Page 16

    Lakeair electronic air cleaners 7 year limited warranty the complete lakeair electronic or hepa air cleaner is warranted by lakeair international, inc. To the original purchaser to be free from defects in material and workmanship under nor- mal use and service for a period of one year from the date ...