Lamona LAM2502 User's installation manual - page 12
www.howdens.com
Page _ 12
LAMONA Appliances
Electrical
Connections
,03257$17(QVXUHWKDWWKHHOHFWULFLW\VXSSO\LVVZLWFKHGRIIEHIRUHFRQQHFWLQJ
with at least 3mm contact separation, The isolation switch must be accessible after installation. (See technical data for fuse rating). :HVWURQJO\UHFRPPHQGWKHDSSOLDQFHLVFRQQHFWHGE\DTXDOLÀHGHOHFWULFLDQ The terminology DOUBLE POLE -/+ means that both the live and neutral supplies are switched and disconnected at the same time. The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the appliance. ,03257$177KHZLUHVLQWKHPDLQVOHDGDUHFRORXUHGLQDFFRUGDQFHZLWKWKHIROORZLQJFRGH Blue.....................Neutral Brown..................Live Green/ Yellow.....Earth As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your spur box, proceed as follows; The wire which is coloured blue must be connected to the terminal which is marked with the letter ‘N’ or coloured BLACK. The wire which is coloured brown must be connected to the terminal which is marked with the letter ‘L’ or coloured RED. The wire which is coloured Green and Yellow must be connected to the terminal which is marked with the letter ‘E’ or Symbol Fig 3. Fig 4. N L L N LOAD SUPPLY LOAD SUPPLY DP 13A 250V~ FUSE ON Blue. (Neutral) Brown. (Live)