Lampoassa P 10-15 User Manual

Summary of P 10-15

  • Page 1

    User manual lÄmpÖÄssÄ t/p 10 – 31 lÄmpÖÄssÄ 5/2013 ground source heat pumps since 1983 as long as the sun exists let mother earth heat your home.

  • Page 2

    2 ground source heat pumps since 1983.

  • Page 3

    3 ground source heat pumps since 1983 content 1. General information 4 1.1. Safety precautions 4 1.2. Transportation 4 1.3. Installation area 4 1.4. Removing the packaging 5 1.5. Structure and operating principles 5 1.5.1. Structure 5 1.5.2. Operation 5 2. Installation 6 2.1. Before installation 6 2...

  • Page 4

    4 ground source heat pumps since 1983 1. General information we thank you for your confidence in our products and congratulate you on making an excellent choice! You have selected a long-lasting and environmentally friendly lämpöässä geothermal heat system. We hope that you will enjoy lämpöässä’s he...

  • Page 5

    5 ground source heat pumps since 1983 1.4. Removing the packaging remove the plastic wrapping and corner padding from around the product. Check that the heat pump has not suffered any damage during transportation. If the heat pump is found to be damaged, the company which delivered the product must ...

  • Page 6

    6 ground source heat pumps since 1983 2. Installation 2.1. Before installation pipe assemblies for the installation of the lämpöässä system may only be installed by qualified persons. The unit must be installed in accordance with the instructions provided and a check list must be reviewed after inst...

  • Page 7

    7 ground source heat pumps since 1983 2.3. Connecting the collector pipe assemblies of the: lämpöässä t 10-15 lämpöässä p 10-15 1 2 collector pipe assemblies optionally on both sides. Connect asseblies to the collector pipe with care. 1. Collector pipe, flow (cu 28mm) 2. Collector pipe, return (cu 2...

  • Page 8

    8 ground source heat pumps since 1983 the filling and de-aeration process of t 10-15 / p 10-15 please check that the ground loop has been correctly connected (see “connecting the ground loop” section) and that the compressor has been preheated (see ”safety precautions” section). 1. Install filling a...

  • Page 9

    9 ground source heat pumps since 1983 the filling and de-aeration process of t 21-31 / p 21-31 please check that the ground loop has been correctly connected (see “connecting the ground loop” section) and that the compressor has been preheated (see ”safety precautions” section). 1. Install filling a...

  • Page 10

    10 ground source heat pumps since 1983 2.6. Heating connection the heating circuit 1 is the main circuit with higher temperature e.G. Heating with radiators. The heating circuit 2 is the secondary circuit with lower temperature e.G underfloor heating. Pipes in the heating network are connected to th...

  • Page 11

    11 ground source heat pumps since 1983 2.9. Electrical installation only qualified electricians are permitted to carry out electrical work on the heat pump according to general regulations. Device t 10 / p 10 t 13 / p 13 t 15 / p 15 t 21 / p 21 t 31 / p 31 electrical connection 400v 3n~ 400v 3n~ 400...

  • Page 12

    12 ground source heat pumps since 1983 2.9.3. Actuators ouman 201 connection strip cable type mixing valve motor 51, 52, 53 3 x 1,5 mm 2 ouman 203 connection strip cable type heating circuit 1 mixing valve motor 51, 52, 53 3 x 1,5 mm 2 heating circuit 2 mixing valve motor 55, 56, 57 3 x 1,5 mm 2 dhw...

  • Page 13

    13 ground source heat pumps since 1983 possible problems during startup problem cause solution fuses always blow when the compressor is being started. You are using the wrong type of fuse. Check that the fuse is automatic: c or d/ ceramic fuse: slow or with a snail icon. Temporary connections at the...

  • Page 14

    14 ground source heat pumps since 1983 3. User information 3.1. Lämpöässä settings information in this section has been compiled from the lämpöässä 201gt/203gt manual, which, in addition to the following, includes more detailed information on the various functions and detailed reading(s). 3.2. Care ...

  • Page 15

    15 ground source heat pumps since 1983 thermal relays go off immediately when power is switched on. The protection switch for the motor goes off if the equipment is short-circuited or one of the phases is not on. Contact an electrician. Fuses in the master switchboard of the building are faulty. Che...

  • Page 16

    16 ground source heat pumps since 1983 4. Technical specifications 4.1. Chart lämpöässä t 10 / p 10 t 13 / p 13 t 15 / p 15 t 21 / p 21 t 31 / p 31 dimensions width depth height mm mm mm 590 640 1400 780 780 1300 weight kg 180 200 220 280 318 electrical connection 400v 3n~ supplied output 35/50°c * ...

  • Page 17

    17 ground source heat pumps since 1983 5. Warranty suomen lämpöpumpputekniikka oy offers a two- (2) year warranty with the lämpöässä t geothermal heat pumps it manufactures. The manufacturer shall not be responsible for any breakages of equipment which is not installed cor- rectly, any brekages of e...

  • Page 28

    LÄmpÖÄssÄ is a registered trademark of suomen lämpöpumpputekniikka oy. All rights reserved. Suomen lämpöpumpputekniikka oy unikontie 2 fi-62100 lapua finland www.Lampoassa.Com r.