Lampoassa V 10.5 User Manual

Summary of V 10.5

  • Page 1

    1 ground source heat pumps since 1983 user manual lÄmpÖÄssÄ v 7.0 — 30.0 lÄmpÖÄssÄ 3/2010 as long as the sun exists let mother earth heat your home.

  • Page 2

    2.

  • Page 3

    3 ground source heat pumps since 1983 contents 1. General information 5 1.1. Safety precautions 5 1.2. Transportation 5 1.3. Installation area 5 1.4. Removing the packaging 6 1.5. Structure and operating principles 6 1.5.1. Structure 6 1.5.2. Operation 6 2. Installation 7 2.1. Before installation 7 ...

  • Page 4

    4.

  • Page 5

    5 ground source heat pumps since 1983 1. General information we thank you for your confidence in our products and congratulate you on making an excellent choice! You have selected a long-lasting and environmentally friendly lämpöässä geothermal heat system. We hope that you will enjoy lämpöässä’s he...

  • Page 6

    6 1.4. Removing the packaging remove the plastic wrapping and corner padding from around the product. Check that the heat pump has not suffered any damage during transportation. If the heat pump is found to be damaged, the company which delivered the product must be immediately notified. Also check ...

  • Page 7

    7 ground source heat pumps since 1983 2. Installation 2.1. Before installation pipe assemblies for the installation of the lämpöässä system may only be installed by qualified persons. The unit must be installed in accordance with the instructions provided and a check list must be reviewed after inst...

  • Page 8

    8 2.4. Filling and de-aeration of the ground loop equipment required for the filling and deaeration of the ground loop: • mixing tank, 60 litres • a submersible pump fitted with a filter, lifting height approximately 30 m • water and ethyl alcohol, or glycol-water mixture (1:1) with a frost resistan...

  • Page 9

    9 ground source heat pumps since 1983 deaeration can be made more efficient by using the pump on the ground loop of the heat pump. The circulation water pump on the ground loop and the submersible pump used in the deaeration are then connected in series. The circula- tion water pump on the ground lo...

  • Page 10

    10 2.7. Hepac check list check that • the connections are tight and there are no leaking valves • the expansion tank on the heating system and fill side is properly installed • the overflow pipe on the shut-off valve and the pressure gauge on the heating system have been properly installed • the hea...

  • Page 11

    11 ground source heat pumps since 1983 2.9. Electricity check list check that • all phases going to the switchboard are in the correct phase sequence • the fuse size is correct (slow) 2.10. Startup before startup, check that: • the heating system has been connected, filled and deaerated appropriatel...

  • Page 12

    12 3. User information 3.1. Lämpöässä settings information in this section has been compiled from the lämpöässä 203/gt manual, which, in addition to the following, includes more detailed information on the various functions and detailed reading(s). 3.1.1. Settings for heating curve the single most i...

  • Page 13

    13 ground source heat pumps since 1983 use the browser button to move the cursor to “heating curve”. Press ok. Press ok. Use keys – or + to set the value for the output water when the outdoor tempe- rature is -20°c. Press ok. Press ok. Use keys – or + to set the value for the output water when the o...

  • Page 14

    14 the most common set values: set value setting range comment room temperature 21.5°c 5–45°c room temperature set value set by the user. During the night reduction, the regulator uses the calculated room temperature value. Effect of night reduc- tion 0°c 0–35°c the amount of night reduction for out...

  • Page 15

    15 ground source heat pumps since 1983 3.1.3. Measurements the lämpöässä 203 regulator can take 14 concurrent readings (11 ntc readings and 2 digital inputs). The display only shows the readings related to the regulator. There are 2 free readings. Operating instructions: press esc until the display ...

  • Page 16

    16 3.2. Care and maintenance the lämpöässä heat pump is an easy-care heating system. It requires no regular maintenance. If the installation is carried out carefully and in accordance with the instructions provided, there is usually no need for maintenance. The fill container inside the geothermal h...

  • Page 17

    17 ground source heat pumps since 1983 the set value and measured value for the regulator do not match. A maximum limit has been used for the set values. A spiking over-voltage caused by a lightning strike has caused a fault in the condenser, causing the temperature to drop from the actual values. T...

  • Page 18

    18 4. Technical specifications 4.1. Chart lämpöässä heat pump v 7.0 v 9.0 v 10.5 v 13.0 v 15.0 v 20.0 v 30.0 dimensions width depth height mm mm mm 900 650 1900 900 650 1900 900 650 1900 1050 650 1900 1050 650 1900 1250 800 1900 1250 800 1900 weight kg 430 435 440 490 495 600 630 compressor scroll s...

  • Page 19

    5. Warranty suomen lämpöpumpputekniikka oy offers a two- (2) year warranty with the lämpöässä v geothermal heat pumps it manufactures. The manufacturer shall not be responsible for any breakages of equipment which is not installed cor- rectly, any brekages of equipment which is installed contrary to...

  • Page 20

    Current control relays adjusting and connecting these values are default values you can get change those values. Relays have to adjust always case sensitive. 1. Choice correct current area • turn switch 2 position on (when main fuse are less than 50a) • others switchs 1,3-6 position off. 2. Adjust h...

  • Page 32