Lancaster 7-LMC56-75B Installation, Operating And Service Manual

Summary of 7-LMC56-75B

  • Page 1

    Page 1 installation, operating and service manual econo-mist water softener demand regeneration in the event that you need assistance for servicing your water softener, please first contact the professional contractor who installed the system. Congratulations on purchasing your new lancaster water f...

  • Page 2

    Page 2 installation place softener in desired location close to water supply inlet, after pressure tank, and near a source for waste water, (utility sink, floor drain or sewer line). Keep far enough away from walls and other obstructions to allow enough room for servicing the unit. All sillcocks and...

  • Page 3

    Page 3 placing unit into service: 1. Manually index the softener control into the backwash position. Slowly open bypass valve and allow water to flow into the resin tank. When the water flows steadily to drain without the presence of air, index control to service position. Note: the various regenera...

  • Page 4

    Page 4 no. 60353-10 power head assembly (less cover) item no. Qty. Part no. Description item no. Qty. Part no. Description 1 1 15494 drive panel 22 1 19205 24 hour gear assy. 2 1 14333 front label 24 1 14176 valve position dial 3 1 13018 idler pinion 25 1 14177 knob 4 1 13312 idler spring 26 1 15151...

  • Page 5

    Page 5 control valve assembly item no. Qty. Part no. Description item no. Qty. Part no. Description item no. Qty. Part no. Description 1 4 13255 adapter clips 22 1 13163 injector body 42 1 12086 1.5 gpm button 2 5 13424 seals 23 1 10913 injector nozzle 1 12089 2.4 gpm button 3 1 61400-12 valve body ...

  • Page 6

    Page 6 item no. Qty. Part no. Description 1 1 h4600 3/8” safety brine valve 2 1 10151 pin 3 1 h4640-9.5 float assembly 4 1 h4500-48 air check assembly (uncut length) 4740 brine valve assembly • • • •• •• • • • • • • • •• • • • • • • • • • • • • • •• • • • • • • • •• • • • • • • • • click to buy now!...

  • Page 7

    Page 7 service instructions to replace brine valve, injectors, and screen: unplug electrical cord from outlet. Turn off water supply to softener. Relieve water pressure in the softener by putting the control in the backwash position momentarily. Return the con- trol to the service position. Disconne...

  • Page 8

    Page 8 a division of c-b tool co. 1340 manheim pike ● lancaster pa 17601-3196 ● tel:717-397-3521 ● fax: 717-392-0266 www.Lancasterwatertreatment.Com ● e-mail: info@lancasterpump.Com 11/16 troubleshooting procedures problem possible cause solution 1. Softener fails to regenerate. A. Electrical servic...