Lancer 500 Series Operation Manual

Other manuals for 500 Series: Installation And Service Manual
Manual is about: Counter Electric Dispenser

Summary of 500 Series

  • Page 1

    Lancer corp 6655 lancer blvd. San antonio, texas 78219 to order parts, call customer service: 800-729-1500 warranty/technical support: 800-729-1550 email: custserv@lancercorp.Com www.Lancercorp.Com manual pn: 28-0063/06 november 10, 2014 for qualified installer only counter electric dispenser lancer...

  • Page 2

    About this manual this booklet is an integral and essential part of the product and should be handed over to the operator after the instal- lation and preserved for any further consultation that may be necessary. Please read carefully the guidelines and warn- ings contained herein as they are intend...

  • Page 3

    3 4.11 compressor does not start (no hum), but condensor fan motor runs..................................................................................................................................18 4.12 compressor starts and continues to run unbtil freeze up and will not cut off..................

  • Page 4

    Touchpoint specifications dimensions width: 10 3/8 in (264 mm) depth: 25 1/4 in (641 mm) height (w/out legs): 22 15/16 in (583 mm) space required left side: 4 in (101.6 mm) right side: 4 in (101.6 mm) back: 4 in (101.6 mm) top: 8 in (203.2 mm) electrical 115vac/60hz/4.3amps 230-240vac/50-60hz/2.6amp...

  • Page 5

    Pre-installation checklist before getting started each unit is tested under operating conditions and is thoroughly inspected before shipment. At the time of shipment, the carrier accepts responsibility for the unit. Upon receiv- ing the unit, carefully inspect the carton for visible damage. If damag...

  • Page 6

    Warning/advertencia/avertissement ! The dispenser is for indoor use only. This appliance is intended for use in commercial applications such as res- taurants, stores or similar. This unit is not a toy. It should not be used by children or infirm persons without supervi- sion. This appliance is not i...

  • Page 7

    Dispenser installation highlights this unit has been factory sanitized per lancer specifications. Listed below are six critical elements which will aid in a successful installation. 1. Fill water bath until water overflows from tank overflow tube. 2. The carbonator pump motor must be disconnected fr...

  • Page 8

    Electrical warning/advertencia elÉctrica/ avertissement Électrique f check the dispenser serial number plate for correct electrical requirements of unit. Do not plug into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all loca...

  • Page 9

    Automatic agitation/agitaciÓn automÁtica/ ! Units are equipped with an automatic agitation system and will activate unexpectedly. Do not place hands or for- eign objects in the water bath tank. Unplug the dispenser during servicing, cleaning, and sanitizing. To avoid personal injury, do not attempt ...

  • Page 10

    1. Installation 1.1 recieving the unit each unit is completely tested under operating conditions and thoroughly inspected before ship- ment. At time of shipment, the carrier accepts the unit and any claim for damage(s) must be made with carrier. Upon receiving units from the delivering carrier, care...

  • Page 11

    11 1.4 connecting to electrical power note: adhere to the electrical warnings/cautions, page 8. F grounding warning the dispenser must be properly electrically grounded to avoid serious injury or fatal electrical shock. The power cord has a three-prong grounded plug. If a three-hole grounded electri...

  • Page 12

    1.6 connecting the co2 supply a. Connect high pressure co2 regulator assembly to co2 cylinder or bulk system. Use a new co2 tank washer if regulator does not have built-in o-ring seal. B. Place co2 cylinder in service location under counter, etc., and secure it with a safety chain. C. Install second...

  • Page 13

    1.10 adjusting water flow (lev ® ) a. The water flow can be adjusted between 1.25 oz/ sec (37 ml/sec) and 2.50 oz/sec (74 ml/sec) on all dispensing valves using the following procedures. B. The refridgeration unit should have been running for at least one (1) hour before you attempt to brix the valv...

  • Page 14

    2.5 yearly a clean water bath interior, including evaporator coils and refrigeration components. B. Clean the entire exterior of the unit. C. Sanitize syrup lines. 3. Dispenser cleaning and sanitization 3.1 general information a. Lancer equipment (new or reconditioned) is shipped from the factory cl...

  • Page 15

    15 3.4 valves a. Valves may be cleaned and sanitized in the same manner b. Remove cover and disconnect power so not to activate the valve while cleaning. Remove nozzle and diffuser. Wash these parts in cleaning solution, then immerse them in a bath of sanitizing solution for 15 minutes. C. Visually ...

  • Page 16

    Trouble cause remedy 4.1 water leakage around nozzle. A. Damaged or improperly installed o-ring above diffuser. A. If damaged, replace. If imporoperly installed, adjust. 4.2 leakae between upper and lower valve bodies. A. Gap between upper and lower valve bodies. B. Worn or damaged paddle arm assemb...

  • Page 17

    Trouble cause remedy 4.7 no product dispensed a. Water and syrup shutoffs on mounting block not fully open. B. The key switch on an electric valve is in the off position. C. Cup lever arm or id panel actuator on electric valve is not actuating the switch. D. Electric current not reaching valve. E. I...

  • Page 18

    Trouble cause remedy 4.11 compressor does not start (no hum), but condenser fan motor runs a. Compressor relay or overload malfunctioning. B. Inadequate voltage. C. Incorrect wiring. D. Compressor malfunctioning a. Replace compressor relay or overload. B. Measure voltage across common and run termin...

  • Page 19

    5. Dispenser disposal to prevent possible harm to the environment from improper disposal, recycle the unit by locating an authorized recycler or contact the retailer where the product was pur chased. Comply with local regulations regarding disposal of the refrigerant and insulation. Trouble cause re...

  • Page 20

    6.2 cabinet assembly 9 4 1 2 22 6 7 8 16 22 11 21 23 24 10 14 12 13 17 3 27 18 15 22 5 24 25 26 16 15 22 19 20 20

  • Page 21

    Item part no. Description 1 30-5260/01 wrapper, cabinet 2 07-0347 plate, cover 3 23-1111 cup rest 4 51-0735 drip tray assy 5 30-5037 frame, drip tray 6 52-0843 wire harness, 2 valve - 52-2103 wire harness, 3 valve - 52-0842 wire harness, 4 valve 7 52-0849/01 wire harness, key lock (optional) 8 42-00...

  • Page 22

    6.3 compressor deck assembly 2 4 4 7 3 6 5 29e 29b 29d 29c 29a 23 16 22 17 27,28 20 30a,30b,30c 6 30 18 13 9 4 31 14 31 10c 10a 10d 10b 19 8 1 4 24 29 10 21 12 32 26 25 11 15 33 34 22.

  • Page 23

    6.3 compressor deck assembly (continued) item part no. Description - 82-2662 compressor deck assy, 115v/60hz - 82-2665 compressor deck assy, 230v/50hz - 82-2666 compressor deck assy, 240v/60hz 1 82-2096 deck sub assy, with insulation 2 23-0955 condenser 3 30-5884 fan shroud 4 04-0504 screw, 8 - 18 x...

  • Page 24

    6.4 500 ced wiring diagram, 115v/60hz, lancer electronic ice bank control label, wiring diagram, ced, pn 06-0031/01 control housing connections 24 green black white 120 ac jct. Agitator motor 24v leads transformer lancer ice bank control probe relay fan motor compressor overload c m s l m s label, w...

  • Page 25

    25 6.5 500 ced wiring diagram, 220-240v/50-60hz, lancer electronic ice bank control when starting unit or if current is interrupted, there is a five (5) minute delay before the compressor/fan starts. Important 06-2093 used on pn 82-2665 (230v/50hz) and pn 82-2666 (240v/60hz) green black white jct 22...

  • Page 26

    Lancer to order parts, call customer service: 800-729-1500 warranty: 800-729-1550 email: custserv@lancercorp.Com www.Lancercorp.Com.