Landa ENG10-3000 Operator's Manual

Summary of ENG10-3000

  • Page 1

    Operator’s manual for technical assistance or the dealer nearest you, consult our web page at www.Landa.Com eng4-2000 eng4-2200 eng4-3000 eng5-2300  eng5-3000 eng6-3200  eng8-3200 eng10-3000 eng listed ® 9.801-511.0 98015100-1 gr ou nd 8 10 12 14 16 0 2 4 6 tach/hou r tach/hou r 1. Pla ce all sw i...

  • Page 2: Symbols

    Eng • 9.801-511.0 • rev. 9/13a symbols pump switch detergent steam combination hour meter motor overload when the light is on, it means the overload is tripped. Reset overload. Pilot light when the light is on, it means there is power to the pilot control. If there is no light, see troubleshooting g...

  • Page 3: Contents

    3 contents eng • 9.801-511.0 • rev. 9/13a identification of operational label symbols 2 introduction & safety information 4-6 component identification-all models 7 installation eng 4-2000, 4-2200, 4-3000, 5-2300, 5-3000 8 installation eng 6-3200, 8-3200, 10-3000 9 installation 10-16 assembly instruc...

  • Page 4: Important Safety

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 4 introduction & important safety information thank you for purchasing this pressure washer. We reserve the right to make changes at any time without incurring any obligation. Owner/user responsibility: the owner and/or user must have ...

  • Page 5: Important Safety Information

    Eng • 9.801-511.0 • rev. 9/13a 5 pressure w asher deale r’s manu al important safety information warning use protective eye wear and clothing when operating this equipment. Warning: high pressure spray can cause paint chips or other particles to become airborne and fly at high speeds. To avoid perso...

  • Page 6: Important Safety Information

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 6 important safety information 22. Install optional lp gas regulator assembly, item 9.802-633.0 or obtain a proper size regulator. 23. Install this machine about 2 feet from wall to provide adequate ventilation and servicing space. Thi...

  • Page 7

    Eng • 9.801-511.0 • rev. 9/13a 7 pressure w asher deale r’s manu al component identification - all models pump — delivers a specific gpm to the high pressure nozzle which develops pressure. (not shown) spray gun — controls the application of water and detergent onto cleaning surface with trigger dev...

  • Page 8

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 8 installation eng 4-2000, 4-2200, 4-3000, 5-2300, 5-3000 98015100-3 36.00" minimum control panel 19.50" dia. Customer supplied draft diverter 24.00" 24.87" 4.00" high pressure out 3/8" qc nipple 48.54" 36.68" 24.50" 24.00" 12.00" 49.0...

  • Page 9

    Eng • 9.801-511.0 • rev. 9/13a 9 pressure w asher deale r’s manu al 98015100-4 installation eng 6-3200, 8-3200, 10-3000 36" minimum piping to outside floor mounting dimensions 19.50" dia customer supplied draft diverter control panel 61.00" 17.33" 34.79" 17.36" 26.18" 3.64" high pressure out 3/8" qc...

  • Page 10: Installation

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 10 installation install a gas union in the gas line adjacent to and up- stream from the control manifold and downstream from the manual main shut-off valve. A 1/8" npt plugged tapping accessible for test gauge connection shall be insta...

  • Page 11: Installation

    Eng • 9.801-511.0 • rev. 9/13a 11 pressure w asher deale r’s manu al containers are equipped with a fixed liquid level gauge which contacts the liquid level at 80% of container ca- pacity, allowing 20% for expansion. Lp-gas containers not equipped with a fixed liquid level gauge can only be filled b...

  • Page 12: Installation

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 12 two inches from combustibles. Vents passing through enclosed spaces and vents exposed to the weather should also be the double-wall type. Sometimes vents have to be built of such great length that they come apart at their joints und...

  • Page 13: Installation

    Eng • 9.801-511.0 • rev. 9/13a 13 pressure w asher deale r’s manu al inspection and testing gas piping: the building structure should not be weakened by installing the gas piping. The piping should not be supported by other piping, but should be firmly sup- ported with gas hooks, straps, bands or ha...

  • Page 14: Installation

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 14 installation this process can also be used when turning down the firing rate for high altitude installations above 2000 ft. 1. Adjust the gas pressure down 4% for every 1000 ft of elevation. Example: recommended firing rate for a 4....

  • Page 15: Installation

    Eng • 9.801-511.0 • rev. 9/13a 15 pressure w asher deale r’s manu al warning read safety instructions prior to installing or servicing machine . Installation for your safety read before lighting warning if you do not follow these instructions exactly, a fire or explosion may result, causing property...

  • Page 16: Installation

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 16 installation yes no has gas supply been inspected by an authorized contractor to meet local codes? Is machine protected from downdraft and excessive wind? Is machine shielded from moisture or water spray? Is the voltage correct and ...

  • Page 17: Assembly Instructions

    Eng • 9.801-511.0 • rev. 9/13a 17 pressure w asher deale r’s manu al 98015100-6 98015100-5 assembly instructions step 1: attach the high pressure hose to the spray gun using teflon tape on hose threads. Move safety latch into locked position to prevent spray gun trigger from activating. Step 4: conn...

  • Page 18: Operating Instructions

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 18 8 10 12 14 16 0 2 4 6 tach/h our tach/h our inst rucciones de oper ac ion lea el manu al de oper ac iÓn a ntes de u sarse. La oper aciÓn nad ec ua da pued e oc asiona r lesiones perso nales o da Ños a las pr opie dade s. Rup tore s ...

  • Page 19: Thermal Pump

    Eng • 9.801-511.0 • rev. 9/13a 19 pressure w asher deale r’s manu al 98015100-19 detergent valve warning: some detergents may be harmful if inhaled or ingested, causing severe nau- sea, fainting or poisoning. The harmful elements may cause property damage or severe injury. Step 1: use detergent desi...

  • Page 20: Shutting Down and Cleanup

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 20 ru cciones d er ac iÓn an te ona r l es opie 98015100-21 caution: failure to follow the above directions will result in damage to your pressure washer. After extended storage caution: prior to restarting, thaw out any possible ice f...

  • Page 21: Troubleshooting

    Eng • 9.801-511.0 • rev. 9/13a 21 pressure w asher tr oub leshooting guide troubleshooting problem possible cause solution water temperature too hot incoming water to machine warm or hot lower incoming water temperature. Gas pressure too high see specifications for proper gas pressure. Detergent lin...

  • Page 22: Troubleshooting

    Eng • 9.801-511.0 • rev. 9/13a p ressure w asher tr oub leshooting guide 22 troubleshooting problem possible cause solution oil dripping oil seal worn check and replace if necessary. Low operating pressure faulty pressure gauge install new gauge. Insuffient water supply use larger garden hose. Clean...

  • Page 23: Troubleshooting

    Eng • 9.801-511.0 • rev. 9/13a 23 pressure w asher tr oub leshooting guide troubleshooting problem possible cause solution flow & burner switch on; no spark, no pilot gas a. No main power b. Faulty transformer c. Faulty burner & flow switch d. Faulty ignition control unit with power switch on, open ...

  • Page 24: Troubleshooting

    Eng • 9.801-511.0 • rev. 9/13a p ressure w asher tr oub leshooting guide 24 troubleshooting problem possible cause solution have pilot flame, main burner will not turn on faulty main valve coil in the gas valve set test meter to 24 volt scale. Faulty ignitor/sensor and/or its wiring with pilot flame...

  • Page 25: Maintenance and Service

    Eng • 9.801-511.0 • rev. 9/13a 25 pressure w asher deale r’s manu al maintenance and service spray nozzles: each machine is equipped with one or more spray nozzles, depending on the model. Different spray nozzles are calibrated for each machine, depending on the flow and pressure of that particular ...

  • Page 26: Maintenance & Service

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 26 maintenance & service gas valve regulator adjustment 98015100-26 on/off switch inlet view outlet manifold pressure adjustment screw under cap gas valve regulator adjustment lines to pilot light gas valve regulator adjustment adjustm...

  • Page 27: Maintenance & Service

    Eng • 9.801-511.0 • rev. 9/13a 27 pressure w asher deale r’s manu al maintenance & service 2. To clean burner jets: select proper size drill for type gas involved. Use pin vise to hold drill and ream out each jet orifice. Caution: do not ream out orifices to a larger size. If the water heater will b...

  • Page 28: Maintenance and Service

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 28 maintenance and service basic facts based on 60° propane butane 1 cu. Ft. Ng approx 1000 btu formula c3h8 c4h10 vaporization point (°f) -43.7 31.1 specific gravity (vapor) 1.522 2.006 specific gravity (liquid) 0.508 0.584 lbs. Per g...

  • Page 29: Oil Change Record

    Eng • 9.801-511.0 • rev. 9/13a 29 pressure w asher deale r’s manu al oil change record pressure equivalents simply stated, pressure is the force exerted by a gas or liquid attempting to escape from a container. It is useful to know how strong this “attempt to escape” is. Pressure can be measured wit...

  • Page 30: Preventative Maintenance

    Eng • 9.801-511.0 • rev. 9/13a dealer’s manu al pressure w asher 30 preventative maintenance this pressure washer was produced with the best available materials and quality craftsmanship. However, you as the owner have certain responsibilities for the correct care of the equipment. Attention to regu...

  • Page 31

    Eng • 9.801-511.0 • rev. 9/13a pressure w asher w arranty landa limited new product warranty pressure washers what this warranty covers all landa pressure washers are warranted by landa to the original purchaser to be free from defects in materials and workmanship under normal use, for the periods s...

  • Page 32

    Form #9.801-511.0 • revised 9/13a • printed in u.S.A..