Landa VLP10-2000 Operator's Manual

Summary of VLP10-2000

  • Page 1

    96-610 operator’s manual for technical assistance or the dealer nearest you consult our web page at www.Landa.Com or call 360-833-1600 ■ vng/vlp4-2000 ■ vng/vlp4-3000 ■ vng/vlp6-3000 ■ vng/vlp8-3000 ■ vng/vlp10-2000 vng vlp p r e s s u r e w a s h e r s ®.

  • Page 3: Contents

    3 contents 96-610 • landa vng/vlp • rev. 9/05 introduction & important safety information 5-6 component identification 7 installation 8-12 location 8 gas codes 8 electrical 8 gas piping 8,10 installation guide 9 propane gas 10 natural gas 10 venting 10 draft diverter 10 water source 11 water connect...

  • Page 4: Contents

    Contents 4 96-610 • landa vng/vlp • rev. 9/05 model number ______________________________ serial number ______________________________ date of purchase ____________________________ the model and serial numbers will be found on a decal attached to the pressure washer. You should record both serial nu...

  • Page 5: Important Safety

    96-610 • landa vng/vlp • rev. 9/05 5 pressure w asher opera t or’s manu al introduction & important safety information thank you for purchasing a landa pressure washer. This manual covers the operation and maintenance of the vng/vlp4-20021a, 4-20021a/r, 4-20021b, 4-20021b/r, 4-20021c, 4-20021c/r, 4-...

  • Page 6: Important Safety Information

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 6 important safety information caution: hot discharge fluid. Do not touch or direct dis- charge stream at persons. 9. Never make adjustments on machine while in operation. Warning: high pressure can cause paint chips or other p...

  • Page 7: Component Identification

    96-610 • landa vng/vlp • rev. 9/05 7 pressure w asher opera t or’s manu al component identification side panel spray gun draft diverter high pressure nozzle & coupler water supply hose (not included) high pressure hose variable pressure control handle trigger voltage light pump light pressure gauge ...

  • Page 8: Installation

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 8 installation place machine in a convenient location providing ample support, drainage and room for maintenance. Location: this machine is certified for indoor installation. Its location should protect the machine from damag- ...

  • Page 9: Installation

    96-610 • landa vng/vlp • rev. 9/05 9 pressure w asher opera t or’s manu al 12.00" 2.00" high pressure out 3/8" hp nipple 12.00" dia. 25.00" dia. 24.00" control panel detergent in 5.00" 1.00" 2.00" 1.50" 1.50" 8.75" 5.75" 5.00" 6.00" 57.00" gas in 1" npt-m elect. In 3/4 npt 42.63" 5.75" 21.21" 8.75" ...

  • Page 10: Installation

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 10 propane gas: the following pipe sizes should be used between the regulator and the gas valve on the burner. Distance from regulator pipe size 0 - 50' 1" 1 ps 50' - 100' 1-1/2" 1 ps 100' - 200' 1-3/4" 1 ps natural gas: the fo...

  • Page 11: Warning & Check List

    96-610 • landa vng/vlp • rev. 9/05 11 pressure w asher opera t or’s manu al water source: water source for machine should be supplied by a 5/8" i.D. Garden hose with a city water pressure of not less than 30 psi. If the water supply is inadequate, or if the garden hose is kinked, the machine will ru...

  • Page 12: Installation

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 12 installation check list before starting: warning has electronic spark ignition. Do not attempt to light manually. Caution: if “no” has been checked on any of the above questions, do not operate the machine. Caution: this mac...

  • Page 13: Operation Instructions

    96-610 • landa vng/vlp • rev. 9/05 13 pressure w asher opera t or’s manu al operation instructions 1.Stop! Read operator’s manual before operating this machine. Failure to read operation and warning instructions may re- sult in personal injury or prop- erty damage. 2. Turn all switches off. 3. Revie...

  • Page 14: Cleaning Techniques

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 14 cleaning techniques pre-rinse cleaning surface with fresh water. Place de- tergent suction tube directly into cleaning solution and apply to surface at low pressure (for best results, limit your work area to sections approxi...

  • Page 15: Maintenance

    96-610 • landa vng/vlp • rev. 9/05 15 pressure w asher opera t or’s manu al maintenance preventative maintenance 1. Check to see that water pump is properly lubri- cated. 2. Follow winterizing procedures to prevent freeze damage to the pump and coils. 3. Always neutralize and flush detergent from sy...

  • Page 16: Maintenance & Service

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 16 maintenance & service heating coil condensation from heating coil when cold water is being pumped into the water heater coil, and the burner is on, condensation will form on the coil and drip down into the burner compartment...

  • Page 17: Maintenance & Service

    96-610 • landa vng/vlp • rev. 9/05 17 pressure w asher opera t or’s manu al maintenance & service exterior regulators are needed to control the system. Propane bottles are not included with the machine. A high pressure regulator should be installed on the pro- pane bottle and a low pressure regulato...

  • Page 18: Preventative Maintenance

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 18 preventative maintenance this pressure washer was produced with the best available materials and quality craftsmanship. However, you as the owner have certain responsibilities for the correct care of the equipment. Attention...

  • Page 19: Troubleshooting - Burner

    96-610 • landa vng/vlp • rev. 9/05 19 pressure w asher t ro u b leshooting guide troubleshooting - burner problem possible cause solution flow & burner switch on; no spark, no pilot gas a. No main power with power switch on, open trigger on spray gun and set your test meter to the 24 volt scale. Pro...

  • Page 20: Troubleshooting - Burner

    96-610 • landa vng/vlp • rev. 9/05 pressure w asher t ro u b leshooting guide 20 troubleshooting - burner problem possible cause solution have pilot flame, main burner will not turn on faulty main valve coil in the gas valve set test meter to 24 volt scale. Faulty ignitor/sensor and/or its wiring wi...

  • Page 21: Troubleshooting

    96-610 • landa vng/vlp • rev. 9/05 21 pressure w asher t ro u b leshooting guide troubleshooting problem possible cause solution low operating pressure faulty pressure gauge install new gauge. Insufficient water supply use larger garden hose; clean filter washer at water inlet. Old, worn or incorrec...

  • Page 22: Troubleshooting

    96-610 • landa vng/vlp • rev. 9/05 pressure w asher t ro u b leshooting guide 22 troubleshooting problem possible cause solution water temperature too hot incoming water to machine warm or hot lower incoming water temperature. Gas pressure too high call local gas company. Detergent line sucking air ...

  • Page 23: Troubleshooting

    96-610 • landa vng/vlp • rev. 9/05 23 pressure w asher t ro u b leshooting guide troubleshooting problem possible cause solution fluctuating pressure valves worn check and replace if necessary. Blockage in valve check and replace if necessary. Pump sucking air check water supply and air seepage at j...

  • Page 24

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 24 exploded view - 4-2000, 4-3000 for detail see electrical box illus. 39 2 4 3 1 2 5 5 37 38 35 36 40 41 40 41 34,98 10 10 9 6 31 28 8 7 6 8 7 12 15 16 30 14 30 11 for detail see electrical box illus. 20 21 25 18 19 17 97 24 2...

  • Page 25

    96-610 • landa vng/vlp • rev. 9/05 25 pressure w asher opera t or’s manu al exploded view - 4-2000, 4-3000 45 remote control box 54 80 53 52 44 42 43 104 50 51 49 46 55 56 57 60 58 59 90 87 81 82 87 91 86 63 84 85 92 88 87 91 64 62 65 66 29 71 69 68 67 72 75 70 79 93 73 76 74 61 94 40 41 101 41 41 4...

  • Page 26

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 26 4-2000, 4-3000 exploded view parts list item part no. Description qty 1 95-07163062 panel, side vng-s 2 2 90-50033 latch, vise action 4 3 2-011041 trim, w/sponge 26.5 ft. 4 95-07163057 panel, top vng-s 1 5 90-2022 nut, cage,...

  • Page 27

    96-610 • landa vng/vlp • rev. 9/05 27 pressure w asher opera t or’s manu al 4-2000, 4-3000 exploded view parts list item part no. Description qty 72 95-071210136 platform, motor 3/16" 1 73 95-07121112 rail, pump, general combo 1 74 90-1016 bolt, 3/8" x 1" nc hh 16 75 2-01011 isolator, 5/16" fem x fe...

  • Page 28

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 28 exploded view - 6-3000, 8-3000, 10-2000 for detail see electrical box illus. 5 3 4 2 1 12 31, 77 29 30 25 26 27 28 24 34 17 17 10 6 7 7 8 6 for detail see control panel illus. 32 32 32 11 17 69 42 66 6 62 11 - for detail see...

  • Page 29

    96-610 • landa vng/vlp • rev. 9/05 29 pressure w asher opera t or’s manu al exploded view - 6-3000, 8-3000, 10-2000 33 45 30 65 44 65 71 63 64 44 46 29 29 30 74 41 23 67 48 23 opt. Remote control box 55 61 60 59 56 53 57 58 51 30 29 45 45 54 76 29 74 72 18 73 15 16 68 for detail see burner illus. Mo...

  • Page 30

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 30 6-3000, 8-3000, 10-2000 exploded view parts list item part no. Description qty 1 95-07163020 panel, side, small, vng-l 2 2 95-07163018 panel, side, large, vng-l 2 3 2-011041 trim, 1/16", w/sponge 55 ft. 4 90-50033 latch, vis...

  • Page 31

    96-610 • landa vng/vlp • rev. 9/05 31 pressure w asher opera t or’s manu al 6-3000, 8-3000, 10-2000 exploded view parts list item part no. Description qty 63 95-07121112 rail, pump (6-3) 1 95-071211129 rail, pump (8-3,10-2) 1 64 95-07163042 power platform, vng-l 1 65 2-0108 bumper pad, engine 21 66 ...

  • Page 32: Control Panel Assembly

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 32 control panel assembly 1 16 18 18 18 17 16 13 16 16 9 22 32 11 17 17 4 7 31 25 20 40 detergent remote operating system 24 23 28 19 26 8 27 10 5 37 36 - detergent line to pump inlet 18 30 1 steam line to pump steam line to pu...

  • Page 33: Control Panel Parts List

    96-610 • landa vng/vlp • rev. 9/05 33 pressure w asher opera t or’s manu al control panel parts list item part no. Description qty 1 4-05088 thermostat, general, 302° 1 2 2-0026 elbow, 1/4" female pipe 1 3 4-02021236 hose, 1/4" x 36", 2 wire ga. (s) 1 4 90-4005 washer, 5/8" flat 2 5 2-9040 clamp, ho...

  • Page 34: Control Panel Parts List

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 34 item part no. Description qty 36 4-02090000 tube, braided vinyl (small) 36" (large) 41" 37 2-9000 clamp, screw 1 38 2-1085 hose barb, 1/4" barb x 1/4 1 39 4-02080000 tube, 1/4" x 1/2", clear vinyl 10 ft. 2-1905 ▲ strainer, 1...

  • Page 35

    96-610 • landa vng/vlp • rev. 9/05 35 pressure w asher opera t or’s manu al vngl float tank (#30-536) exploded view 9 9 7 4 3 5 2 6 6 1 9 8 vngl float tank (#30-536) parts list item part no. Description qty 1 95-07163021 assembly, float tank, s.S. 1 2 2-30110 valve, float, 3/4" brass 1 3 2-1112 stem...

  • Page 36

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 36 vng 6-300, 8-3000 burner assembly 22 6 4 8 4 21 4 51 15 19 14 33 6 22 2 23 1 3 4 5 10 13 37 7 17 22 18 29 25 24 31 28 32 30 4 22 16 35 33 4 34 42 41 40 39 43 36 12 38 from pump/unloader to machine outlet 44 50 48 11 20 27 26...

  • Page 37

    96-610 • landa vng/vlp • rev. 9/05 37 pressure w asher opera t or’s manu al vng 6-300, 8-3000 burner parts list item part no. Description qty 1 95-07163087 module, wrap, outer, large coil 1 2 95-031610/54l burner ring, w/jets 54" 1 95-031610/65l burner ring, w/jets 65" (lp option) 1 3 95-07163084 do...

  • Page 38

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 38 vng-l 10-2000 burner assembly 17 31 15 8 42 21 18 6 5 2 11 25 26 27 38 29 28 24 39 37 4 30 38 6 25 35 36 37 7 11 10 9 7 6 6 13 12 6 14 34 11 33 20 3 ignitor assy. W/cable 19 23 22 45 47 46 43 42 40 41 16 48.

  • Page 39

    96-610 • landa vng/vlp • rev. 9/05 39 pressure w asher opera t or’s manu al vng-l 10-2000 burner parts list item part no. Description qty 1 2-00295 elbow, 1" x 3/4" reducing, blk 2 2 2-001312 nipple, 1" x 5", black pipe 1 3 6-01352 cable, ignitor, 48" 1 4 7-70003 valve, gas, v8943b1010/b (ng) 1 7-70...

  • Page 40

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 40 vng electrical box - auto start 8 15 17 18 6 4 5 5 2 4 1 19 7 12 14 11 3 16 13 9 24 2 9 9 10 9 1 1 8 6 20 20 2 21 23 remote option 23 25 25.

  • Page 41

    96-610 • landa vng/vlp • rev. 9/05 41 pressure w asher opera t or’s manu al vng electrical box - auto start parts list item part no. Description qty 1 90-1991 screw, 10/32" x 1/2" bhsoc 15 2 95-07163030 panel, electrical box, side 2 3 6-0504 block, terminal, 4 pole 1 90-16 ▲ screw, 8/32" x 3/4" 2 90...

  • Page 42

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 42 vng electrical box - time delay 17 5 1 7 16 13 6 3 4 2 18 15 16 8 8 10 9 22 1 1 14 12 11 2 15 5 6 16 21 20 remote option item part no. Description qty 1 90-1991 screw 10/32" x 1/2" bhsoc 15 2 95-07163030 panel, electrical bo...

  • Page 43

    96-610 • landa vng/vlp • rev. 9/05 43 pressure w asher opera t or’s manu al vng remote electrical box - all models 6-0517 6-05041 10-3014 6-020530 6-2020 6-0390 6-2001 6-2000 6-03901 cable to electrical box remote unit (customer installed) 6-2020 cable to remote unit (to be installed by electrician).

  • Page 44

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 44 vng 4-2000, 4-3000, 6-3000 pump assembly 1 16 14 15 18 3 5 6 4 7 8 9 11 12 20 10 17 13 19 3 6 17 9 22 10 12 11 12 15 1 16 18 4 8 7 14 5 19 13 from float tank 20 21 22.

  • Page 45

    96-610 • landa vng/vlp • rev. 9/05 45 pressure w asher opera t or’s manu al vng 4-2000, 4-3000, 6-3000 parts list item part no. Description qty 1 pump, see parts specifications pages 2 95-07121112 ▲ rail, pump 1 3 6-021730 switch, flow mv60, yellow 1 4 5-3208 unloader, al-vrt607, 7.8gpm 1 5-3027 unl...

  • Page 46

    96-610 • landa vng/vlp • rev. 9/05 opera t or’s manu al pressure w asher 46 vng 8-3000, 10-2000 pump assembly to pressure gauge 6 7 7 3 5 4 29 9 8 15 to float tank 10 9 11 13 12 14 3 to float tank 1 22 18 19 17 21 16 23 24 26 25 24 27 3 20 28 30

  • Page 47

    96-610 • landa vng/vlp • rev. 9/05 47 pressure w asher opera t or’s manu al vng 4-2000, 4-3000, 6-3000 parts list item part no. Description qty 1 5-1743 pump, landa lx8030/l (8-3) 1 5-1748 pump, landa lx1025/l (10-2) 1 2 95-071211129 ▲ rail, pump combo 1 3 2-10620 elbow, 3/4" sae x 3/4", 90°, brass ...

  • Page 48: Basic Facts

    96-610 • landa vng/vlp • rev. 9/05 pressure w asher specifications 48 basic facts based on 60 o f propane butane formula c3h8 c4h10 vaporization point ( o f) -43.7 31.1 specific gravity (vapor) 1.522 2.006 specific gravity (liquid) 0.508 0.584 lbs. Per gallon (liquid) 4.23 4.87 b.T.U. Per cubic foot...

  • Page 49: Burner Specifications

    96-610 • landa vng/vlp • rev. 9/05 49 pressure w asher specifications burner specifications l e d o m r e n r u b y l b m e s s a e z i s t e j e v l a v s a g e c i f i r o t o l i p n o i s r e v n o c 0 0 0 2 - 4 g n v 6 4 - x 4 5 # 4 0 3 8 b v " 4 / 3 o n 0 0 0 3 - 4 g n v 6 4 - x 4 5 # 4 0 3 8 ...

  • Page 50: Specifications

    96-610 • landa vng/vlp • rev. 9/05 pressure w asher specifications 50 specifications parts specifications: landa pump machine pump pulley bushing pulley model model part # pulley part # bushing part # size voltage/ph hertz part # pulley part # bushing 4-20024a lt5030 5-1728 2ak84h 5-40208401 25mm 5-...

  • Page 51: Specifications

    96-610 • landa vng/vlp • rev. 9/05 51 pressure w asher specifications specifications parts specifications: landa pump (con't) model bushing belt belt motor motor stepdown primary primary secondary secondary stepdown (con't) part # size/qty part # contact overload transformer fuse fuse part # fuse fu...

  • Page 52: Specifications

    96-610 • landa vng/vlp • rev. 9/05 pressure w asher specifications 52 specifications parts specifications: general pump machine pump pulley bushing voltage/ pulley model model part # pulley part # bushing part # size ph hertz part # pulley part # bushing 4-20021a t-1011 5-2304 2ak84h 5-40208401 24mm...

  • Page 53: Specifications

    96-610 • landa vng/vlp • rev. 9/05 53 pressure w asher specifications specifications parts specifications: general pump (con't) model bushing belt belt motor motor stepdown primary primary secondary secondary stepdown (con't) part # size/qty part # contactor overload transformer fuse fuse part # fus...

  • Page 55

    96-610 • landa vng/vlp • rev. 9/05 55 pressure w asher w arranty landa limited new product warranty pressure washers what this warranty covers all landa pressure washers are warranted by landa to the original purchaser to be free from defects in materials and workmanship under normal use, for the pe...

  • Page 56

    Form #96-610 • revised 9/05 • printed in u.S.A. Water cleaning systems ®.