Lanex TM-78 Operating manual - Operating Safety
10Base-T/100Base-TX/E1 Converter
Operating Manual
IOA78-1C IV January 2005
Operating Safety
The EtherTel TM-78 converter has been designed and tested in the range of safety and
operation in accordance with the PN-EN-60950 standards. It conforms to Class I safety
requirements.
!
The earthing clamp located on the rear wall of the device should be connected
to earth.
!
The device is not provided with an integrated tripping system. Such system
should be located outside the device.
The manufacturer shall not be held liable for use of the device contrary to this
operating manual.
The operating manual is a part of supply and is delivered to users together with
the device.
Summary of TM-78
Page 1
Ioa78-1c january 2005 lanex s.A., 8 ceramiczna street, 20-150 lublin poland service phone no. +48 81 443 96 39 ethertel 10/100base-t/ e1 converter tm-78 operating manual.
Page 2: Table of Contents
10base-t/100base-tx/e1 converter operating manual ioa78-1c i january 2005 table of contents 1. G eneral description ......................................................................................... 1 1.1. Designed use .............................................................................
Page 3: Drawings
10base-t/100base-tx/e1 converter operating manual ioa78-1c ii january 2005 drawings figure 1-2: example application ii. ............................................................................... 2 figure 1-3: example application iii..................................................................
Page 4: Abbreviations
10base-t/100base-tx/e1 converter operating manual ioa78-1c iii january 2005 abbreviations ais alarm indication signal nual non-urgent alarm ual urgent alarm es errored seconds es15 15-minute errored seconds counter es es24 24-hour errored seconds counter es hdlc high level data link control ieee ins...
Page 5: Operating Safety
10base-t/100base-tx/e1 converter operating manual ioa78-1c iv january 2005 operating safety the ethertel tm-78 converter has been designed and tested in the range of safety and operation in accordance with the pn-en-60950 standards. It conforms to class i safety requirements. ! The earthing clamp lo...
Page 6: 1. G
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 1 january 2005 1. G eneral description 1.1. Designed use ethertel tm-78 is a converter that enables connecting independent segments of local area networks in eth...
Page 7
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 2 january 2005 1.2. Sample applications one of the simplest applications is the possibility of providing internet access service using telecommunication network ...
Page 8
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 3 january 2005 e1/g.703 ethernet object 1 2048kbit/s e1/g.703 2048kbit/s 2048kbit/s e1/g.703 ethernet ethernet ethernet switch e1/g.703 2048kbit/s host ethernet ...
Page 9: 2. C
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 4 january 2005 2. C onnectors and led indicators 2.1. Front panel 10/100base-t/e1 converter ethertel rs-232 5-rx 4-sg 6-tx loop1 10/100base-t e1 loop2 lo s lo f ...
Page 10
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 5 january 2005 2.2. Rear panel 1 2 3 4 5 mdi 1 mdi 2 mdix 2 10/100base-t 5v e1 figure 2-2: layout and description of the rear panel. 1. Ethernet interface jacks ...
Page 11
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 6 january 2005 2.3. Description of connectors description of rj-45 connector 4 – supply common 5 – rxd 1 8 6 – txd figure 2-3: rj-45 surveillance connector descr...
Page 12: 3. F
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 7 january 2005 3. F unctional description 3.1. Rule of operation the converter is equipped with 3 ports. Two ports are used for connecting external network segme...
Page 13
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 8 january 2005 ethernet interface: • loss of connection • packets transmission • port configuration following automatic negotiation alarm conditions are signaled...
Page 14: Testing Tract E1/g.703.
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 9 january 2005 use of diagnostic loops is only justified during installation of devices, for testing tract e1/g.703. The loops may not be activated during normal...
Page 15
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 10 january 2005 3.5. Quality management quality management refers to surveillance of transmissoin quality in line g.703/e1 ensured by the device, and to package ...
Page 16
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 11 january 2005 unavailability detection unavailable period available period time availability detection severely errored second errored second, no ses unerrored...
Page 17: 4. I
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 12 january 2005 4. I nstallation & o peration 4.1. Introduction proper installation and configuration of the device in accordance with guidelines contained in th...
Page 18
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 13 january 2005 4.4. Connecting connection cables 4.4.1. Ethernet interface pin1 pin8 1 white-orange 2 orange 3 white-green 4 white-blue 5 blue 6 green 7 white-b...
Page 19
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 14 january 2005 4.5. Attachment of surveillance cables so that management of devices is possible, the monitored device must be connected with a pc with lanwin so...
Page 20
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 15 january 2005 4.6. Clock setup three variants of converter operation are possible. The converters may transmit data, depending on conditions and capacity of th...
Page 21: 5. C
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 16 january 2005 5. C onverter setup with l an w in software the lanwin application in its local version enables surveillance and monitoring of the tm-78 converte...
Page 22
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 17 january 2005 5.1.1. Device name after you press the device name button, a window will open for entering the name. During work with the device, the name entere...
Page 23
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 18 january 2005 5.2. Interfaces the interfaces tab is designed for managing e1 and ethernet interfaces. It contains subtabs of the above interfaces. Each subtab ...
Page 24: Testing Tract E1/g.703.
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 19 january 2005 5.2.1.1. E1, loops tab figure 5-6: interfaces - e1, loops. This tab allows activation of the following loops on the side of the e1 interface: • l...
Page 25
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 20 january 2005 5.2.1.2. E1, monitoring tab. Figure 5-7: interfaces - e1, monitoring. This tab enables viewing the e1 interface signaling. An event is signaled t...
Page 26
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 21 january 2005 5.2.1.3. Ethernet, setup tab figure 5-8: interfaces - ethernet, setup. In this tab, you can change transmission parameters of ethernet interfaces...
Page 27
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 22 january 2005 5.2.1.4. Ethernet, monitoring tab. Figure 5-9: interfaces - ethernet, monitoring. In this tab, you can view the ethernet interface signaling. The...
Page 28
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 23 january 2005 5.3. Global clock figure 5-10: global clock. In this tab you can select clock source for data transmitted in the direction of e1/g.703 line inter...
Page 29
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 24 january 2005 5.4. Log 5.4.1. Event log tab figure 5-11: log - event log. The event log tab displays recorded events related to the converter. The types of rec...
Page 30
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 25 january 2005 5.4.2. Event log tab, event log filters figure 5-12: log - event log filters. This tab is divided into two parts. The upper section of the tab di...
Page 31
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 26 january 2005 figure 5-13. Event log filter – date..
Page 32
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 27 january 2005 figure 5-14. Event log filter – ual/nual..
Page 33
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 28 january 2005 5.5. G.826 statistics in this tab, you can set start time for counting: • of errored seconds - es • of severely errored seconds - ses • of errore...
Page 34
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 29 january 2005 figure 5-15. G.826 statistics – 15-minute counters. Figure 5-16. G.826 statistics – 24-hour counters..
Page 35
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 30 january 2005 figure 5-17. G.826 statistics – time periods. Figure 5-18. Count initialization time. Figure 5-19. Ranges..
Page 36
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 31 january 2005 figure 5-20. Alarm on thresholds. Figure 5-21. Alarms hierarchy..
Page 37: 6. T
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 32 january 2005 6. T echnical specification 6.1. Electrical characteristics 6.1.1. Ethernet interface parameter value of the parameter standard describing the el...
Page 38
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 33 january 2005 6.3. Environmental requirements 6.3.1. Operation the converter may operate indoors, in unevenly heated rooms, in the following ambient conditions...
Page 39: 7. P
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 34 january 2005 7. P roduct elements and accessories the complete packing list of the product delivered to the customer includes: 1. Ethertel tm-78 converter 1 p...
Page 40
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 35 january 2005.
Page 41
10base-t/100base-tx/e1 converter operating manual _______________________________________________________________________________ ioa78-1c 36 january 2005 manufacturer: lanex s.A. 8 ceramiczna street 20-150 lublin poland phone: +48 81 444-10-11 fax: +48 81 740-35-70 e-mail: info@lanex.Pl web: www.La...