Lanier Toner for 6113, 6213, 6413, 6514 117- 0225 Datasheet
Lanier Worldwide, Inc.
2300 Parklake Dr., N. E.
Atlanta, GA 30345-2979
Emergency Telephone: (800)526-4371
MATERIAL SAFETY DATA SHEET
1
Section 1: Chemical Product and Company Information
Identity:
Toner for 6113, 6213, 6413, 6514
MSDS No.
CP-300
Product ID:
117- 0225
Issued:
9/17/98
Synonyms
& Common
Names:
Uses:
Chemical
Formula:
Toner, Black Toner for Lanier
M6113, 6213, 6413, 6514
M6113, 6213, 6413, 6514 Copier
Mixture, Inert resinated black
powder
Supersedes:
Date:
Prepared by:
European
Contact:
3/11/96
9/17/98
Lanier QA/EH&S Department
Lanier Worldwide, WSM Europe,
Walter Fricke,
Im Taubental D-41468 Neuss,
Germany +49-2131-387-177
Section 2: Composition / Information on Ingredients
PERCENT
CAS No.
EXPOSURE LIMITS
SOURCE
Styrene-acrylic resin
85 ~ 90
25767-47-9
not listed
n/a
Carbon black
5 ~ 10
1333-86-4
3.5mg/m
3
3.5mg/m
3
OSHA PEL ACGIH TLV
Wax
1 ~ 5
9003-07-7
not listed
n/a
Organic pigment
1 ~ 5
102561-46-6
not listed
n/a
Silica
< 1
7631-86-9
not listed
n/a
*PEL of the product: 15mg/m
3
(total dust), 5mg/m
3
(respirable dust)
*TLV of the product: 10mg/m
3
(total dust), 5mg/m
3
(respirable dust)
Section 3: Hazards Identification
HMIS Rating:
FLAMMABILITY = 0 HEALTH = 0
REACTIVITY = 0 SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-toxic dust. May
cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test toner revealed there
were no lung changes at all in the lowest exposure level (1mg/m
3
), the most relevant level to potential human exposures. A very slight degree of fibrosis was
noted in 25% of the animals at the middle exposure level (4mg/m
3
), while a slight degree of fibrosis was observed at the highest exposure level (16mg/m
3
) in
all animals. These findings are attributed to “Lung Overloading”, a generic response to excessive amount of any dust retained in the lungs for a prolonged
interval. The special test toner was ten times more respirable than commercially available toner to comply with EPA testing protocol and would not function
properly in xerographic equipment.
Section 4: First Aid Measures
Inhalation:
Remove to fresh air if effects occur. Consult
local medical personnel
Eye Contact
:
In case of contact, immediately flush eyes with
water for 5 minutes.
Skin Contact:
Wash with soap and water.
Ingestion
:
Dilute stomach contents with water. Call a
physician.
Section 5: Fire Fighting Measures
Suitable extinguishing media:
CO
2
, dry chemical, foam or water.
Extinguishing media which may not be used for safety reasons: none
This material will burn in case of fire.
The decomposition products are CO, CO
2
, and No
x
. Avoid inhalation of smoke.
Special protective equipment for fire fighters: none
UEL: n/a LEL: n/a