Lantech IES-0208CA User manual

Manual is about: 8 10/100TX + 2 10/100/1000T/DUAL Speed Combo Industrial Switch

Summary of IES-0208CA

  • Page 1

    Lantech ies-0208ca 8 10/100tx + 2 10/100/1000t/dual speed combo industrial switch user manual v1.00 apr 2014.

  • Page 2: Fcc Warning

    Fcc warning this equipment has been tested and found to comply with the limits for a class-a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, an...

  • Page 3: Content

    Content introduction .............................................................. 1 features ................................................................. 1 package contents .................................................. 2 hardware description .................................................

  • Page 4: Introduction

    1 introduction the 8 10/100tx + 2 10/100/1000t/dual speed sfp combo industrial switch is a cost- effective solution and meets the high reliability requirements demanded by industrial applications. Using fiber port can extend the connection distance that increases the network elasticity and performan...

  • Page 5: Package Contents

    2 package contents please refer to the package content list below to verify them against the checklist. 8 10/100tx + 2 10/100/1000t/dual speed sfp combo industrial switch pluggable terminal block user manual 2 wall mount plates with screws one din-rail (attached on the switch) compare the contents o...

  • Page 6: Hardware Description

    3 hardware description in this paragraph, it will describe the industrial switch ’s hardware spec, port, cabling information, and wiring installation. Physical dimension 8 10/100tx + 2 10/100/1000t/dual speed sfp combo industrial switch dimension (w x d x h) is 72mm x 105mm x 152mm front panel the f...

  • Page 7: Top View

    4 front panel of the industrial switch top view the top panel of the 8 10/100tx + 2 10/100/1000t/dual speed sfp combo industrial switch has one terminal block connector of two dc power inputs. Top panel of the industrial switch.

  • Page 8: Led Indicators

    5 led indicators the diagnostic leds located on the front panel of the industrial switch provide real-time information of system and optional status. The following table provides description of the led status and their meanings for the switch. Led status meaning pwr1 green power 1 is active off powe...

  • Page 9: Ports

    6 p9 ~ p10 (10/100/1000t) green (upper led) connected to network blinking (upper led) networking is active off (upper led) not connected to network green (lower led) the port is operating at speed of 1000m off (lower led) the port is disconnected or operates at speed of 10/100m p9 ~ p10 link/active ...

  • Page 10

    7 6 rx- note “+” and “-” signs represent the polarity of the wires that make up each wire pair. All ports on this industrial switch support automatic mdi/mdi-x operation, user can use straight-through cables (see figure below) for all network connections to pcs or servers, or to other switches or hu...

  • Page 11: Cabling

    8 cable for the connection up to 1000mbps. The sfp slots supporting dual mode can switch the connection speed between 100 and 1000mbps. They are for connecting to the network segment with single or multi-mode fiber. You can choose the appropriate mini-gbic module to plug into the slots. You can use ...

  • Page 12

    9 bottom of the module. Figure 2.8: transceiver to the sfp module make sure the module is aligned correctly and then slide the module into the sfp slot until a click is heard. Figure 2.9: transceiver inserted.

  • Page 13

    10 second, insert the fiber cable of lc connector into the transceiver. Figure 2.10: lc connector to the transceiver to remove the lc connector from the transceiver, please follow the steps shown below: first, press the upper side of the lc connector from the transceiver and pull it out to release. ...

  • Page 14

    11 second, push down the metal loop and pull the transceiver out by the plastic part. Figure 2.12: pull out from the sfp module.

  • Page 15: Wiring The Power Inputs

    12 wiring the power inputs please follow the steps below to insert the power wire. 1. Insert the positive and negative wires into the v+ and v- contacts on the terminal block connector. 2. To tighten the wire-clamp screws for preventing the dc wires to loose..

  • Page 16

    13 wiring the fault alarm contact the fault alarm contact is in the middle of terminal block connector as the picture shows below. Inserting the wires, it will detect the fault status which the power is failure or port link failure (for managed model) and form an open circuit. Note the wire gauge fo...

  • Page 17: Mounting Installation

    14 mounting installation din-rail mounting the din-rail is screwed on the industrial switch when out of factory. If the din-rail is not screwed on the industrial switch, please see the following pictures to screw the din- rail on the switch. Follow the steps below to hang the industrial switch..

  • Page 18

    15 1. First, insert the top of din-rail into the track. 2. Then, lightly push the din-rail into the track. 3. Check if the din-rail is tightened on the track or not. 4. To remove the industrial switch from the track, reverse steps above..

  • Page 19: Wall Mount Plate Mounting

    16 wall mount plate mounting follow the steps below to mount the industrial switch with wall mount plate. 1. Remove the din-rail from the industrial switch; loose the screws to remove the din- rail. 2. Place the wall mount plate on the rear panel of the industrial switch. 3. Use the screws to screw ...

  • Page 20: Hardware Installation

    17 hardware installation in this paragraph, we will describe how to install the 8 10/100tx + 2 10/100/1000t/dual speed sfp combo industrial switch and the installation points to be attended to it. Installation steps 1. Unpack the industrial switch packing. 2. Check if the din-rail is screwed on the ...

  • Page 21: Network Application

    18 network application this chapter provides some sample applications to help user to have more actual idea of industrial switch function application. A sample application of the industrial switch is shown as below:.

  • Page 22: Troubles Shooting

    19 troubles shooting verify that you are using the right power cord/adapter (dc 12-48v). Please don’t use the power adapter with dc output higher than 56v, or this switch will be burned down. Select the proper utp/stp cable to construct the user network. Use unshielded twisted-pair (utp) or shield t...

  • Page 23: Technical Specification

    20 technical specification the 8 10/100tx + 2 10/100/1000t/dual speed sfp combo industrial switch technical specifications are as follows. Standard ieee 802.3 10base-t ieee 802.3u 100base-tx ieee 802.3ab 1000base-t ieee 802.3z gigabit fiber ieee 802.3x flow control and back-pressure protocol csma/cd...

  • Page 24

    21 1000base-t: 2-pair utp/stp cat. 5e or 6 cable eia/tia-568 100-ohm (100m) optical cable lc (multi-mode): 50/125um or 62.5/125um lc (single mode): 9/125um back-plane 5.6 gbps packet throughput ability 6.2 mpps at 64bytes power supply 12~ 48 v dc with redundant power input -48 v dc with single power...

  • Page 25

    22 ce en61000-4-11 ce en61000-4-12 ce en61000-6-2 ce en61000-6-4 stability testing iec60068-2-32 (free fall) iec60068-2-27 (shock) iec60068-2-6 (vibration).