Lantech IPES/IES-5416DFT Series User Manual

Manual is about: 16 10/100TX + 2 1000T + 2 100/1000FX Dual Speed Fiber L2+ 8 PoE at/af Industrial Managed Switch w/ITU G.8032 Ring

Summary of IPES/IES-5416DFT Series

  • Page 1

    Ipes/ies-5416dft series 16 10/100tx + 2 1000t + 2 100/1000fx dual speed fiber l2 + 8 poe at/af industrial managed switch w/itu g.8032 ring user manual (hardware) ip-67 ip-43 sep. 2015.

  • Page 2

    Recommendation for shielded network cables stp cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an stp network cable in demanding electrical environments...

  • Page 3: Important Notice

    Important notice lantech communications global, inc. Reserves the right to modify the equipment, its specification or this manual without prior notice, in the interest of improving performance, reliability, or servicing. At the time of publication all data is correct for the operation of the equipme...

  • Page 4: Fcc Warning

    Fcc warning this equipment has been tested and found to comply with the limits for a class-a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, an...

  • Page 5: Content

    Content chapter 1 introduction ............................................. 5 specification ............................................................. 5 chapter 2 hardware description .......................... 12 2.1 physical dimension ...................................... 12 2.2 ip protection...

  • Page 6: Chapter 1  Introduction

    5 chapter 1 introduction lantech ies-5416dft & ipes-5416dft-8(ip67/ip43) series is a high performance l2 + ip67/ip43 industrial gigabit uplink switch with 8x10/100tx + 2 gigat + 2dual speed giga fx w/8 poe at/af injectors by m12 connectors which provides l2 wire speed and advanced security function ...

  • Page 7

    6 jumbo frame 10kb on all ports connectors 10/100tx: 16 x ports m12 4-pole d-coded with auto mdi/mdi-x function 10/100/1000t: 2 x ports m12 8-pole a-coded with auto mdi/mdi- x function 100/1000 dual speed fiber: 2 x lc connector for single-mode or multi-mode type fiber cable rs-232 connector: 1 x m1...

  • Page 8

    7 1 digital output(do): open collector to 40 vdc, 200ma operating humidity 5% ~ 95% (non-condensing) operating temperature -40°c~75°c / -40°f~167°f (72v model: -40°c~60°c / -40°f~140°f) storage temperature -40°c~85°c / -40°f~185°f power supply standard model:9.5~60vdc dual input 72v model: 50.4~90vd...

  • Page 9

    8 ipes-5416dft-8 series standards ieee 802.3 10base-t ethernet ieee 802.3u 100base-tx ieee802.3z gigabit fiber ieee802.3x flow control and back pressure ieee802.3ad port trunk with lacp ieee802.1d spanning tree ieee802.1w rapid spanning tree ieee802.1s multiple spanning tree ieee 802.3ad link aggreg...

  • Page 10

    9 relay contact : 1 x m12 5-pole a-coded network cable 10base-t: 2-pair utp/stp cat. 3, 4, 5/ 5e/ 6 cable eia/tia-568 100-ohm (100m) 100base-tx: 2-pair utp/stp cat. 5/ 5e/ 6 cable eia/tia-568 100-ohm (100m) 1000base-tx: 2-pair utp/stp cat. 5/ 5e/ 6 cable eia/tia-568 100-ohm (100m) giga optical cable...

  • Page 11

    10 72v model: 50.4~90vdc dual input 110v model: 43~137.5vdc dual input poe budget 240w for 45~56v input (55v input is recommended for 802.3at 30w applications) 80w for 12v input 120w for 24v input 80w for 72v input 80w for 110v input poe pin assignment m12 port # 1~#8 support ieee 802.3at/af end-poi...

  • Page 12

    11 warranty 5 years *future release **optional.

  • Page 13: 2.1  Physical Dimension

    12 chapter 2 hardware description in this paragraph, it will describe the industrial switch’s hardware spec, port, cabling information, and wiring installation. 2.1 physical dimension aluminum case. Ip-67, 285 (w) x 201.4 (d) x 84.4 (h) mm.

  • Page 14

    13 port description of ip-67 series switch aluminum case. Ip-43, 273 (w) x 188.4(d) x 84.4 (h) mm **the description of interface of ip-43 model is the same as ip-67 series..

  • Page 15: 2.2  Ip Protection

    14 2.2 ip protection the ip code, ingress protection rating, sometimes also interpreted as international protection rating, classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water in mechanical...

  • Page 16

    15 liquid ingress protection the second digit indicates the level of protection that the enclosure provides against harmful ingress of water. Level protected against testing for details 0 not protected — — 1 dripping water dripping water (vertically falling drops) shall have no harmful effect. Test ...

  • Page 17

    16 6 powerful water jets water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects. Test duration: at least 3 minutes water volume: 100 litres per minute pressure: 100 kpa at distance of 3 m 7 immersion up to 1 m ingress of water in harm...

  • Page 18: 2.3  Led Indicators

    17 2.3 led indicators the diagnostic leds that provide real-time information of system and optional status are located on the front panel of the industrial switch. The following table provides the description of the led status and their meanings for the switch. Led color status meaning r.M green on ...

  • Page 19

    18 off no device attached..

  • Page 20

    19 chapter 3 hardware installation 3.1hardware installation 3.1.1unpack switch and check the accessory with packing list 3.1.2 mount the switch on desired position 3.1.3 connect the m23 connector of power input. The poe supply voltage for ipes-5416dft-8 series is connected via a 5-pin m23 connector ...

  • Page 21

    20 the 802.3af and 802.3at standardized devices. 72v model: the power input voltage can be from 50.4v to 90vdc to feed power on both 802.3af/at standardized devices. 110v model: the power input voltage can be from 43v to 137.5vdc to feed power on both 802.3af/at standardized devices. Make sure that ...

  • Page 22

    21  dual power input the power input can be supported redundantly. The supply voltage is electrically isolated from the housing. Note: with single power supply of the mains voltage, the device will report a power failure. You can disable this power fail event via web browser. Pin assignment of alar...

  • Page 23

    22 ground screw of ipes-5408t switch 3.1.5 connect the m12 connector with rj-45 data cable, ports are not used shall be caped that comes with the package to insulate the surrounding..

  • Page 24

    23 pin assignment of m12 10/100tx network connector pin assignment of m12 10/100/100t network connector.

  • Page 25

    24 3.1.6 check the status of led, make sure the switch was in working status. Note:  the protection class ip67/ip43 is only achieved when bolted together.  the other components attaching to the system have to meet with the ip67/ip43 protection class in order to reach the whole system ip 67/ip43 pr...

  • Page 26: 4.2    Ring Coupling

    25 chapter 4 network application 4.1 itu g.8032 scheme lantech g.8032 protocol is following itu (international telecommunication unit) g.8032 v2 draft. The benefits of g.8032 are: 1. 2. G.8032 has defined the protocol scheme, parameters, functions, test measures to be unified that the users can eval...

  • Page 27: 4.3    Multiple Rings

    26 4.3 multiple rings.

  • Page 28: 4.4    Dual Homing

    27 4.4 dual homing 4.5 chain.

  • Page 29

    28.

  • Page 30

    29 chapter 5 console management 5.1 connecting to the console port the supplied cable which one end is m12 5-pole connector and the other end is rs- 232 connector. Attach the end of rs-232 connector to pc or terminal and the other end of m12 connector to the console port of the switch. The connected...

  • Page 31

    30 the settings of communication parameters having finished the parameter settings, click ‘ok’. When the blank screen shows up, press enter key to have the login prompt appears. Key in ‘admin’ (default value) for both user name and password (use enter key to switch), then press enter and the main me...