Laskomex CD-2502 Series Installation, Service And Programming Manual

Manual is about: DIGITAL ENTRY PHONE SYSTEM

Summary of CD-2502 Series

  • Page 1

    Digital entry phone system installation, service and programming manual cd-2502xx.

  • Page 2

    Contents contents contents 1 conditions of operation 3 2 installation of entry phone 4 3 elements of entry phone 5 4 numbering modes 9 4.1 normal mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4.2 numbering mode with range shift . . . . . . . . . . . . . . . . . ....

  • Page 3

    Contents contents 10 restoring the initial settings 45 11 maintenance of entry phone 46 12 conformity with previous versions 47 12.1 electronic cassette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 12.2 external panel . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 4

    1 conditions of operation note! Entry phone cd-2502 is available in two versions: audio and video. In both versions the same electronic cassette ec-2502 and power supply adapters are used, in both versions parameters are set in the same way. The two versions differ mainly with the types of used pane...

  • Page 5

    2 installation of entry phone it is forbidden to hold the receiver near an ear and push the lever (hook- switch) in the uniphone/monitor base at the same time or hold the receiver near an ear while the lever (hook-switch) is pushed because this may cause a loud call signal in a receiver that can res...

  • Page 6

    3 elements of entry phone in case the system of entrance hierarchy is activated, set the range limits for the apartments in cassettes operating as ec-2502/u (for subordinate entrances). Leaving default settings in these cassettes may cause wrong operation of the entry phone system. In case of need t...

  • Page 7

    3 elements of entry phone illuminator in panels in version video makes it possible to recognize the face at a distance of approx. 50 cm from the video camera. Lighting diodes are placed be- hind the display, so they are effective only if the face of a visiting person is directed towards the entry ph...

  • Page 8

    3 elements of entry phone enclosed to it. Monitor mvc–6550 and 6650 colour monitors for laskomex digital systems. They are loud speaking monitors without receivers with tft display operating in duplex system. Detailed information on monitor assembly and use are included in the instruction enclosed t...

  • Page 9

    3 elements of entry phone power supply ac power supply adapter zs-k-25/01 art.0018 or tszzm 25/021m should be used for supplying electronic cassette. Electro-catch or electromagnetic lock entry phone cd-2502 can control electro-catch or electromagnetic lock. Op- eration time is programmed and can be...

  • Page 10

    4 numbering modes name of casing destination - type of panel description da-1 one segment casing da-2h two segment casing, horizontal da-2v cp-2502xx two segment casing, vertical da-3h three segment casing, horizontal da-3v three segment casing, vertical dax1-1 one segment casing dax1-2h cp-2510 two...

  • Page 11

    4.3 hotel numbering mode 4 numbering modes the number from the keyboard). This numbering mode is used for apartments of numbers higher than 255. Logical number = physical number + range shift this numbering mode is switched on in a moment of setting of parameter value ‘range shift‘ to the value high...

  • Page 12

    4.4 mode with building numbering 4 numbering modes of entry phone programming procedures in the exchange can be used (p-3-5, p-3-6). Numbers of rooms 1... 20 uniphone number 1, 2, ..20 ground floor numbers of rooms 101...120 uniphone number 21, 22,...41 i floor numbers of rooms 201...220 uniphone nu...

  • Page 13

    4.6 additional numbers 5 configurations of entry phone operation 4.6 additional numbers in many cases it is necessary to operate numbers which do not belong to the operated range. In entry phone cd-2502 these numbers can be associated with fourteen physical numbers: 241...254 (parameter un in proced...

  • Page 14

    5.2 system with entrance hierarchy 5 configurations of entry phone operation 3 2 230v 2 2 2 3 3 3 2 230v mv-6450 b ) 3 2 2 ec-2502/u 2 16 4 4 4 2 230v c ) 3 16 2 2 4 4 3 2 2 2 2 cvr-1 cvr-2 mv-6451 230v a ) 2 2 ec-2502/u 2 16 4 2 mvc-6x50 mv-6450 mvc-6x50 mv-6450 mvc-6x50 mvc-6x50 figure 1: basic sy...

  • Page 15

    6 installation and activation ec-2502/u to next distributor ec-2502/u to next distributor signal branches 6 staircase b main entrance 4 18 2 staircase a 2 230 vac power supply 4 cp-25xx ec-2502/h power supply 2 cp-25xx cvp-1 2 230 vac 4 4 4 2 6 cvr-2 18 5 power supply 2 cp-25xx cvp-1 2 230 vac 4 4 4...

  • Page 16

    6.1 performance of wiring system 6 installation and activation in installations with the main entrance operation mode is set in electronic cassette. Depending on the selection they can function as cassettes servicing the main entrance (ec-2502/h) or subordinate entrance (ec-2502/u). Default setting ...

  • Page 17

    6.1 performance of wiring system 6 installation and activation a uniphone and an electronic cassette should not exceed 150m for wire dia. 0.5 mm. This distance can be extended by increasing the cross-section of connecting wires. Ec-2502/u 230 vac 4 power supply 2 2 2 2 2 2 2 figure 4: method of conn...

  • Page 18

    6.1 performance of wiring system 6 installation and activation it is forbidden to make wire branching (e.G. In junction boxes). Wire should be routed from one receiver (monitor, distributor, switch) to the next one. A rule should be obeyed that signal sent to the receiver by one wire and goes out by...

  • Page 19

    6.2 installation of external panel 6 installation and activation ec-2502/u 230 vac 4 branch 1 branch 2 branch 3 branch 4 cvr-x figure 6: branching of video entry phone system by means of distributor cvr-x 6.2 installation of external panel setting jumpers. Set correctly contact jp1 in symmetrizator ...

  • Page 20

    6.3 installation of electronic cassette and power supply adaptor 6 installation and activation is not recommended. 100 136 124 k1 k2 k3 k4 k5 k6 m j g k d p4 j - + jp1 figure 8: external panel – setting output impedance in a panel in video version. Jp2 4 segments display jp2 3 segments display jp1 c...

  • Page 21

    6.3 installation of electronic cassette and power supply adaptor 6 installation and activation dents on the frame left side should be put in the openings in a casing panel. The frame should be pushed so that screws are inserted in frame openings move the frame as shown on the drawing and tighten the...

  • Page 22

    6.4 installation of modules cvp–1 and cvp–2 6 installation and activation entry phone cd-2502 can control electro-catch or electromagnetic lock (or reverse electro-catch). Both elements are controlled in different ways. In case of electro- catch release of entrance interlock takes place after supply...

  • Page 23

    6.5 installation of distributor cvr–1 and cvr–2 6 installation and activation distributors, switches) to wire impedance. Load at c1 input should be set only in one of the switches - installed at the end of the line (by means of jp1 joint) in others all jumpers should be removed from the joint. Load ...

  • Page 24

    6.5 installation of distributor cvr–1 and cvr–2 6 installation and activation it is not recommended to use with mv645x series monitors. It is recommended that wires sections connecting distributor with monitor connected to sockets mon1 and mon2 have comparable length. The same principle refers to wi...

  • Page 25

    6.6 installation of monitor. 6 installation and activation 6.6 installation of monitor. Installation and connection of monitors should be made on the basis of instruction enclosed to models that were used. 6.7 installation and programming of uniphone we assume that for each apartment a uniphone conn...

  • Page 26

    6.8 activation 6 installation and activation start installation procedure (p-3-0). Exit programming mode (e.G. P-8). On display message u lub loc will appear informing about installation proce- dure. Message u informs that installation procedure operates and occupants can use the entry phone. Messag...

  • Page 27

    7 entry phone adjustment cd–2502. 7 entry phone adjustment cd–2502. Elements of entry phone system are preliminarily adjusted and position of internal potentiometers should not be changed without necessity. Entry phone cd-2502 has the following adjustment elements (see dwg. 17): p1 — volume control ...

  • Page 28

    8 programming of entry phone balance control if during a conversation or replacing the receiver there are acoustic disturbances (whistles, squeaks etc.) line balance should be adjusted. For this purpose we call a uniphone installed more or less in the middle of the line length l+, l-. By potentiomet...

  • Page 29

    8 programming of entry phone presented on the following drawing. Scroll right scroll left edition / approval cancel value preview figure 19: function keys in programming mode function key key is used for switching to parameter edition mode and accepting entered values. Using key key it is possible t...

  • Page 30

    8 programming of entry phone p-1 operation parameters of entry phone param. No 1 edition - old value 1 3 param. No 2 1 2 edition - new value return c change acceptation in first column with bold font is a message that is shown on panel‘s display during edition of parameter. In third column are accep...

  • Page 31

    8 programming of entry phone video signal service cain supported video in- puts 0...1234 0 u inputs of cvp-x switch which are serviced by cd system. Value ’0’ of parameter means using a cvp-1 switch, while a value greater than zero means cvp-2 switch - the individual digits in the number means which...

  • Page 32

    8 programming of entry phone p-2 functions realized by entry phone parameters p2 can have values [-0-] or [-1-]. In third column default value of parameter is given. Value [-1-] means switched on function, value [-0-] – switched off function. In fourth column type of electronic cassette (u or h) is ...

  • Page 33

    8 programming of entry phone 3c switching on three- position display 0 u,h function should be switched on when electronic cassette ec-2502 coop- erates with the panel with three position of old type. In such case some messages appearing on the display will be distorted. Switching on the three positi...

  • Page 34

    8 programming of entry phone p-3 installation procedure the procedure facilitates the activation of an entry phone system. Starting procedure p3 enables the installing specialist to check the correctness of functioning of uniphones mounted in apartments without any help of other persons. Activation ...

  • Page 35

    8 programming of entry phone p-4 electronic keys entry phone cd-2502 can be equipped with ibutton and/or rfid electronic key reader. There are three kinds of keys in entry phone. Service keys enable change of entry phone configuration, special keys are used by postmen, administration etc. And keys f...

  • Page 36

    8 programming of entry phone p-4-2 adl addition of key with attributing to apartment u 4 2 1 0 end of operation apartment number position in memory procedure enables adding of key and attributing it to selected apart- ment number, which facilitates keys management. The use of the key is signalled in...

  • Page 37

    8 programming of entry phone p-4-4 del key deleting u,h 4 4 apartment number deleting the key from memory will take place after applying it to the reader. On the display a message cas will appear and a number which defines the memory item in which the deleted key was recorded. Note: to delete specia...

  • Page 38

    8 programming of entry phone p-4-9 ser programming of service key (ad- ministrator) u,h 4 9 service key functions similarly to administrator‘s code it enables to enter programming procedures and service key functions independently of ad- ministrator‘s code. This operation results in replacing the ol...

  • Page 39

    8 programming of entry phone p-5 individual settings in system cd-2502 there is a possibility of individual settings of some parameters of entry phone connected with uniphone calling and functions of combination lock. Values of parameters 1-3 may be changed by occupants by user‘s menu (see page. 43)...

  • Page 40

    8 programming of entry phone parameter no. 5. Entrance service, key 5 in the entry phone it is possible to define how the pushbutton operates the electro-catch at the individual entrances. – — no electro-catch control from the uniphone (monitor). U — pushbutton activates electro-catch at the subordi...

  • Page 41

    9 entry phone use p-6 change of installing specialist‘s code the code of an installing specialists enables entering the entry phone programming code. In case of installing specialists or property administrators it is convenient to use one common code for all entry phones which should be maintained. ...

  • Page 42

    9.2 connection from the main entrance 9 entry phone use receiver. If the receiver in the apartment is picked up, this symbol changes to ouo and a conversation can be conducted. If the receiver in the apartment is not picked up then after several seconds the entry phone will return to normal operatio...

  • Page 43

    9.3 use of uniphone 9 entry phone use be signaled with message call entry phone cd-2502 realizes functions ”fast en- trance” which is used only in entry phone with the main and subordinate entrances. In entry phone without this function one must ring the occupant twice in order to get to his apartme...

  • Page 44

    9.5 using coded lock function 9 entry phone use 9.5 using coded lock function to each apartment one four digit number is attributed which is preliminary defined in the entry phone production process. This code can be changed by an installing specialist or occupant (unless this option is blocked). Do...

  • Page 45

    9.7 user‘s menu 9 entry phone use register new electronic keys. To make changes an occupant must activate user’s menu. Some person in the apartment must help. User‘s menu activation: a) make connection with the apartment (only from the subordinate entrance panel). B) press button with a sign of a ke...

  • Page 46

    10 restoring the initial settings registering of a new electronic key in user’s menu after selecting 8, message [add] will appear on the display. Elec- tronic key should be put to the reader. Message [neu] means that key was recorded in memory and attributed to the apartment. If a key, which was rec...

  • Page 47

    11 maintenance of entry phone default settings the cassette was configured as ec-2502/h, after finishing of this operation the cassette will still operate in this mode. Pushbutton reset is used for momentary stopping the operation of a processor. Its pressing makes that the processor stops working, ...

  • Page 48

    12 conformity with previous versions uniphones should be cleaned with a damp cloth or using the means for cleaning plastics. It is forbidden to use solvents. In case the monitor gets dirty it should be cleaned with a soft and damp cloth. It is recommended to do it with power cut off. No abrasive mat...

  • Page 49

    14 technical data system built on the basis cd-2501 or cd-2502, where to one of the staircases the service of the next staircase should be added entry phone cd-2501/u or cd-2502 can be replaced with entry phone cd-3100. 13 messages about faults the doorphone cd-2502 can signal the following faults: ...

  • Page 50

    14.1 description of terminals 14 technical data ambient temperature (-25 ö+55)‰ degree of protection electronic cassette ec-2502: ip20 external panel cp-xxx: ip44 uniphone (each model for cd-2502): ip30 monitor (each model for cd-2502): ip30 cvr-1, cvr-2, cvp-1, cvp-2, mrl-1: ip30 14.1 description o...

  • Page 51

    14.1 description of terminals 14 technical data external panel k1 el. Supply of the cassette digital part k2 digital data from/to cassette k3 digital mass (display system) k4 loudspeaker of talking cassette k5 analogue mass k6 microphone of talking cassette c1+ video signal output c1- video signal o...

  • Page 52

    15 dimensions of elements 15 dimensions of elements figure 22: dimensions of electronic cassette ec-2502 34 82 132 figure 23: dimensions of distributor cvr-1, cvr-2 and switch cvp-1 and cvp-2 51.

  • Page 53

    15 dimensions of elements figure 24: dimensions of panels cp-2502xx with a frame for mounting under plaster 42 100 80 100 214 10 130 48 364 56 65 38 31 48 9 otw. O 5.5 42 100 80 100 214 10 130 48 544 56 65 38 31 100 80 13 otw. O 5.5 da-2v da-3v figure 25: dimensions of casings mounted on plaster in ...

  • Page 54

    15 dimensions of elements 10 100 634 210 80 130 130 42 48 48 48 48 10 otw. O 5.5 56 65 48 185 210 130 80 38 31 10 100 424 210 80 130 130 42 48 48 48 48 10 otw. O 5.5 56 65 38 31 185 42 100 214 10 130 48 48 5 otw. O 5.5 da-1 185 56 65 38 31 da-2h da-3h figure 26: dimensions of casings mounted on plas...

  • Page 55

    15 dimensions of elements dax1-2v figure 28: dimensions of casings mounted on plaster in vertical arrangement, for cp-2510 dax1-1 dax1-2h figure 29: dimensions of casings mounted on plaster in horizontal arrangement, for cp-2510 54.

  • Page 56

    15 dimensions of elements cp-2520 160 246 81 266 88 np2521 np2522 64 140 34 2,5 64 figure 30: dimensions of panels cp-2520 and panels np2522, np2521 dax2-2v figure 31: dimensions of casings mounted on plaster in vertical arrangement, for cp-2520 55.

  • Page 57

    15 dimensions of elements dax2-1 dax2-2h figure 32: dimensions of casings mounted on plaster in horizontal arrangement, for cp-2520 a) b) figure 33: the way of connection cp panel with np list of occupants using fixing elements a) cp-251x and cp-252x panels, b) cp-2530 panel 56.

  • Page 58

    15 dimensions of elements a) np2531 cp-2530 b) dax3-2v dax3-1 figure 34: a) dimensions of panels cp-2530 and np2531; b) dimensions of casings mounted on plaster in vertical arrangement, for cp-2530 57.

  • Page 59: Staircase 1

    16 selection of wires and connection diagrams 16 selection of wires and connection diagrams cp-25xx electro-catch staircase 1 to another staircases accumulator 12v/6ah 15v dc/1a doorbell button 15v dc/4a option dooropen button list of occupants cp-25xx power supply of electronic cassette power suppl...

  • Page 60: Staircase 1

    16 selection of wires and connection diagrams cvp-1 cp-25xx electro-catch staircase 1 to another staircases accumulator 12v/6ah dooropen button list of occupants cp-25xx distribution cabinet cvr-2 15v dc /4a mvc-6x50 13,5v dc mvc-6x50 to another cvr cvr-1 mv-645x 15v dc mon1 mon2 mon3 mon4 mon4 mon3...

  • Page 61

    16 selection of wires and connection diagrams ec-2502/u 230 v ac 14,5 v ac 0,8 a white brown ac2 ac1 electro-catch button l+ l- l+ l- uniphone uniphone cp-25xx np-xxxx power supply of electronic cassette 12 v ac 1 a ac4 ac3 br own brown lm l+ l- k6 k5 k4 k2 k3 k1 x gs’ k6 k5 k4 k2 k3 k1 x gx gz vz k...

  • Page 62

    16 selection of wires and connection diagrams ec-2502/u 230 v ac 14,5 v ac 0,8 a white brown ac2 ac1 electro-catch l+ l- l+ l- uniphone uniphone cp-25xx 12 v ac 1 a ac4 ac3 brown brown lm l+ l- k6 k5 k4 k2 k3 k1 x gs’ k6 k5 k4 k2 k3 k1 x gx gz vz kz gza vza vp gp gs pr b+ b- ec-2502/h 230 v ac 14,5 ...

  • Page 63

    16 selection of wires and connection diagrams demagnetising zt1 a b ac1 ac2 ac3 ac4 vp vs gs gp 1,85 a vza gza ga vz kz gz electro-catch lock +12v stabilizer l+ l- mc sp pr cs t gd x nc nc jp3 key up figure 39: electronic cassette block diagram monitor feeder* plug rj 45 utp note! - in every monitor...

  • Page 64

    16 selection of wires and connection diagrams electronic cassette ec2502 power supply 13,5v dc/1a local power supply 13,5v dc/1a 230v ac/50hz cvr-2 in mvc-6x50 mon4 mon1 ...... Nc1 l+ l- nc2 230v ac/50hz vc b1 c+ c- gb gnd +15v aud cc gc gs vs 1c- l+ l- 1c+ l+ l- gnd +15v c- l+ l- c+ ac ac - + c- c+...

  • Page 65

    16 selection of wires and connection diagrams to another distributor or change-over switch cvr-x ec-2502/h 14,5 v ac 0,8 a white brown ac2 ac1 cp-25xxv 12 v ac 1 a ac4 ac3 brown brown k6 k5 k4 k2 k3 k1 x gx gz vz kz gza vza vp gp gs pr b+ b- c- c+ cs ec-2502/u 14,5 v ac 0,8 a white brown ac2 ac1 cp-...

  • Page 66

    16 selection of wires and connection diagrams in distributor cvr-x used for branching signal, set load (jumper jp1) to value equal to wire impedance. Electro-catch ec-2502/u 230 v ac 14,5 v ac 0,8 a white brown ac2 ac1 cp-25xxv 12 v ac 1 a ac4 ac3 brown brown lm l+ l- k6 k5 k4 k2 k3 k1 x gs’ k6 k5 k...

  • Page 67

    P–1 operation parameters of entry phone etyp 0,1 0 u,h operation mode of electronic cassette toc 10...255 30 u,h waiting time for picking up the receiver in seconds tro 10...255 120 u,h time of conversation t1d 10...255 100 u,h time of signal generation tpa 20...255 150 u,h pause time try 1...31 5 u...

  • Page 68

    Ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax 671 88 88 e-mail: laskomex@laskomex.Com.Pl, http://www.Laskomex.Com.Pl list of collecting units of used laskomex equipment is available on www.Laskomex.Com.Pl website or telephone no. 42 671 88 68. Product packing should be removed accordin...