    Digital display wall clock ddc2 / ddc4 series installation & user's guide.

  • Page 2

    Omni:chron, mini:master, lathem and the lathem logo are registered trademarks of lathem time corporation. Other product names mentioned in this manual may be trademarks of their respective companies and are hereby acknowledged. Warning: changes or modifications to this product not expressly approved...

  • Page 3

    Table of contents introduction..................................................................................................................................................... 1 clock operation .........................................................................................................

  • Page 4

    Ddc4 (double mount - ceiling) .......................................................................................................... 19 setting the time............................................................................................................................................ 20 ...

  • Page 5

    As a count up timer ............................................................................................................................ 52 as a count down timer ....................................................................................................................... 52 appendi...

  • Page 7

    Page 1 digital display wall clock guide introduction the digital display series wall clocks are designed with 2-inch or 4-inch red led displays that can be viewed from great distances; the 4-inch model as far away as 100 feet, the 2-inch model from as far away as 50 feet. The bright red display show...

  • Page 8

    Digital display wall clock guide page 2 about this manual this manual will guide you through the installation, setup and wiring of your ddc series wall clock. This manual covers the four available ddc series models. The available models and their descriptions are: ddc2-rs / ddc4-rs equipped with a 2...

  • Page 9

    Page 3 digital display wall clock guide optional accessories vse0050 power cord, 6 feet. Ddc series wall clocks are shipped without power cords. Sam0626 double ceiling mount kit for ddc2 or ddc4 series sam0630 double wall mount kit for ddc2 series sam0625 double wall mount kit for ddc4 series vse005...

  • Page 10

    Digital display wall clock guide page 4 sam0626 kit (left) includes: 1 - mounting plate assembly 2 - chase nipples 4 - #10 screws 8 - #10 lock washers 8 - #10 hex nuts sam0630 kit (middle) includes: 1 - mounting plate assembly 2 - modified end caps 2 - chase nipples 4 - #10 screws 8 - #10 lock washe...

  • Page 11

    Page 5 digital display wall clock guide configuring the ddc series wall clock setting the dip switches - ddc2 / ddc4 series ddc2 remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and circuit board assembly out of the case. Place the lens aside and car...

  • Page 12

    Digital display wall clock guide page 6 dip switch settings table 1 - s1 (1-5) secondary clock correction 1 2 3 4 5 secondary clock selection 0=closed 1=open *=factory default 0 0 0 0 0 stand alone * 1 0 0 0 0 3-wire synchronous 0 1 0 0 0 3-wire minute impulse (59 th minute) 1 1 0 0 0 3-wire minute ...

  • Page 13

    Page 7 digital display wall clock guide configuring rs485 communications - ddc2/4-rs series when multiple ddc2 (4)-rs series wall clocks are installed as slave units to either the lathem ltr4- 512 or ltr8-512 master, ltr0 mini-master, terminal manager software or the omni:chron time clock, the last ...

  • Page 14

    Digital display wall clock guide page 8 when used as a rs485 clock, the master clock will send a signal to the wall clock every minute. The 9- volt alkaline battery (not included) is optional in these types of installations. Battery installation - ddc2 / ddc4 series ddc2 remove the four phillips hea...

  • Page 15

    Page 9 digital display wall clock guide ac return) attach the ground wire of the cord (normally green) to the green ground screw located on the inside back of the case. Slide the lens and circuit board assembly back into the case, replace the end cap and secure with the four phillips head screws. Dd...

  • Page 16

    Digital display wall clock guide page 10 replacing an existing ddc4 wall clock when replacing an older style ddc4 wall clock it will be necessary to remove any connectors used by the older style clock and attach the wires to the new ddc series wall clock as described above. Board layout diagram j2 f...

  • Page 17

    Page 11 digital display wall clock guide mounting - ddc2 / ddc4 series the ddc series wall clocks can be mounted directly to a wall, to a single gang outlet box, double hung from the wall or double hung from the ceiling. When deciding where the clock will be mounted, keep in mind that 115vac power m...

  • Page 18

    Digital display wall clock guide page 12 » slide the lens and circuit board assembly back into the case, replace the end cap and secure with the four phillips head screws. Ddc4 » after deciding the location where the clock will be mounted, make two marks 12" apart and horizontal. Note: if mounting n...

  • Page 19

    Page 13 digital display wall clock guide ddc2 note: if mounting near a ceiling, make sure the top of the single gang box is at least 2 1/4" away from the ceiling. Note: make sure you have at least 10 1/2" of side clearance on one side in order to remove the lens and circuit board assembly. » remove ...

  • Page 20

    Digital display wall clock guide page 14 » slide the front panel display back into the case, replace the end cap and secure with the two phillips head screws. Double mount - wall ddc2 requires optional mounting kit (sam0630) ddc4 requires optional mounting kit (sam0625) tools required for mounting t...

  • Page 21

    Page 15 digital display wall clock guide note: the long dimension of the mounting plate must be perpendicular to the ground to assure proper alignment of wall clocks. See page 15, figure 4 for ddc2 details. See page 16, figure 5 for ddc4 details. Ddc2 (double mount - wall) » remove the four phillips...

  • Page 22

    Digital display wall clock guide page 16 ddc4 (double mount - wall) » remove the two phillips head screws from the left and the right end caps of the two ddc4 clocks and remove. Slide the front panel assemblies out of the cases and set aside. » place the two ddc4 clocks back to back and secure by in...

  • Page 23

    Page 17 digital display wall clock guide double mount - ceiling requires optional mounting kit (sam0626) tools required for mounting the clock: flat blade screwdriver phillips head screwdriver 15/16" open end wrench the double ceiling mount plate attaches to a double or single gang box installed sec...

  • Page 24

    Digital display wall clock guide page 18 ddc2 (double mount - ceiling) note: make sure you have at least 10 1/2" of side clearance on one side in order to remove the lens and circuit board assembly. » remove the four phillips head screws from the left and the right end caps of the two ddc2 clocks an...

  • Page 25

    Page 19 digital display wall clock guide ddc4 (double mount - ceiling) note: make sure you have at least 16" of side clearance on one side in order to remove the front panel assembly. » remove the two phillips head screws from the left and the right end caps of the two ddc4 clocks and remove. Slide ...

  • Page 26

    Digital display wall clock guide page 20 setting the time time is set on the ddc series wall clocks by depressing buttons located on the left side of the front panel. There are two setting buttons, "h" for hour and "m' for minute. » to advance the hour or minute to the correct time one digit at a ti...

  • Page 27

    Page 21 digital display wall clock guide ddc2 / 4-rs wiring appendix a - ddc2-rs / 4-rs secondary clock wiring diagrams note: see appendix b for ddc2-rs-24 / ddc4-rs-24 wiring. Stand-alone (115vac) grnd ac in ac rtn b l k b l k 115vac local power set switches 1-5 of s1 as shown. Indicates depressed ...

  • Page 28

    Ddc2 / 4-rs wiring digital display wall clock guide page 22 3-wire synchronous (115vac) open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch wiring applies to secondary wall clocks such as: lathem type ss cincinnati d10 ibm 77 series simplex 77 series, 93-9, 91-9,...

  • Page 29

    Page 23 digital display wall clock guide ddc2 / 4-rs wiring 3-wire synchronous (24vac correction) open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch wiring applies to secondary wall clocks such as: lathem type ss cincinnati d10 ibm 77 series simplex 77 series, 9...

  • Page 30

    Ddc2 / 4-rs wiring digital display wall clock guide page 24 3-wire minute impulse (59 th minute) wiring applies to secondary wall clocks such as: lathem isc 3-wire standard impulse cincinnati d2, d4 stromberg impulse edwards impulse faraday impulse simplex 75 series, 91-4, 93-4, 941-4, 943-4 ibm 75 ...

  • Page 31

    Page 25 digital display wall clock guide ddc2 / 4-rs wiring 3-wire minute impulse (59 th minute with 12 hour correction) b r n / w h t grnd ac in ac rtn a b c v io / w h t y e l / w h t b l k b l k wiring applies to secondary wall clocks such as: lathem isc 3-wire 12hour simplex 91, 941 set switches...

  • Page 32

    Ddc2 / 4-rs wiring digital display wall clock guide page 26 standard electric synchronous to other clocks 115vac from master clock open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m for 24vac correction, use wiring shown on page 23 b l u / w h t run correcti...

  • Page 33

    Page 27 digital display wall clock guide ddc2 / 4-rs wiring standard electric ar-2a 2-wire dual voltage b r n / w h t grnd ac in ac rtn ab pc y e l / w h t b l k b l k to other clocks 24vdc / 48vdc from master clock 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates d...

  • Page 34

    Ddc2 / 4-rs wiring digital display wall clock guide page 28 standard electric ar-2 2-wire dual voltage b r n / w h t grnd ac in ac rtn ab pc y e l / w h t b l k b l k to other clocks 24vdc / 48vdc from master clock 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates de...

  • Page 35

    Page 29 digital display wall clock guide ddc2 / 4-rs wiring synchronous wired to other clocks 115vac from master clock open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch wiring applies to secondary wall clocks such as: cincinnati d8 faraday honeywell st402a h m ...

  • Page 36

    Ddc2 / 4-rs wiring digital display wall clock guide page 30 simplex 59 th minute dual motor to other clocks 115vac from master clock open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m for 24vac correction, use wiring shown on page 23 b l u / w h t run correc...

  • Page 37

    Page 31 digital display wall clock guide ddc2 / 4-rs wiring simplex 45 th minute dual motor to other clocks 115vac from master clock open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m for 24vac correction, use wiring shown on page 23 b l u / w h t run correc...

  • Page 38

    Ddc2 / 4-rs wiring digital display wall clock guide page 32 edwards dual motor to other clocks 115vac from master clock open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m for 24vac correction, use wiring shown on page 23 b l u / w h t run correction b r n / ...

  • Page 39

    Page 33 digital display wall clock guide ddc2 / 4-rs wiring standard electric ar-3 3-wire minute impulse to other clocks 24vdc / 48vdc from master clock 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch b r n / w h t 24 vdc pulse common y e l...

  • Page 40

    Ddc2 / 4-rs wiring digital display wall clock guide page 34 national synchronous wired to other clocks 115vac from master clock open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m for 24vac correction, use wiring shown on page 23 b l u / w h t run correction ...

  • Page 41

    Page 35 digital display wall clock guide ddc2 / 4-rs wiring stromberg synchronous wired (56 th minute) to other clocks 115vac from master clock open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m for 24vac correction, use wiring shown on page 23 b l u / w h t...

  • Page 42

    Ddc2 / 4-rs wiring digital display wall clock guide page 36 cincinnati d1 b r n / w h t grnd ac in ac rtn a common y e l / w h t b l k b l k to other clocks 24vdc / 60vdc from master clock 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m...

  • Page 43

    Page 37 digital display wall clock guide ddc2 / 4-rs wiring cincinnati d6, edwards 2406 ab pc y e l / w h t grnd ac in ac rtn b l k b l k v io / w h t to other clocks 24-36vdc from master clock 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of sw1 as shown. Indicates depressed side of set ...

  • Page 44

    Ddc2 / 4-rs wiring digital display wall clock guide page 38 2-wire pulse alternating (24vdc) open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch a b y e l / w h t grnd ac in ac rtn b l k b l k v io / w h t to other clocks 24vdc from master clock 115vac local powe...

  • Page 45

    Page 39 digital display wall clock guide ddc2 / 4-rs wiring electronic coded b r n / w h t grnd ac in ac rtn b l u / w h t b l k b l k red gray w h t 3510 hz reciever 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m requires 3510hz recei...

  • Page 46

    Ddc2 / 4-rs wiring digital display wall clock guide page 40 straight frequency b r n / w h t grnd ac in ac rtn b l u / w h t b l k b l k red gray w h t 3510 hz reciever 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch h m requires 3510hz rec...

  • Page 47

    Page 41 digital display wall clock guide ddc2 / 4-rs wiring 3-wire minute impulse (58 th minute) b r n / w h t grnd ac in ac rtn a b c v io / w h t y e l / w h t b l k b l k to other clocks 24vdc from master clock 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates dep...

  • Page 48

    Ddc2 / 4-rs wiring digital display wall clock guide page 42 3-wire minute impulse (44 th minute) b r n / w h t grnd ac in ac rtn a b c v io / w h t y e l / w h t b l k b l k to other clocks 24vdc from master clock 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates dep...

  • Page 49

    Page 43 digital display wall clock guide ddc2 / 4-rs wiring 2-wire reverse polarity minute impulse (59 th minute) ab pc y e l / w h t grnd ac in ac rtn b l k b l k v io / w h t to other clocks 24vdc from master clock 115vac local power open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates ...

  • Page 50

    Ddc2 / 4-rs -24 wiring digital display wall clock guide page 44 appendix b - ddc2-rs-24 / ddc4-rs-24 wiring the ddc2-rs-24 and the ddc4-rs-24 allow for 24vac supplied from the master clock or power supply to power it for normal operation. These models can be used in installations where local 115vac ...

  • Page 51

    Page 45 digital display wall clock guide ddc2 / 4-rs -24 wiring ddc2-rs-24 / ddc4-rs-24 wiring h m open 1 2 3 4 5 6 7 8 set switches 1-5 of s1 as shown. Indicates depressed side of switch to other clocks 24vac from master clock b l u / w h t run correction b r n / w h t b l k b l k ac return.

  • Page 52

    Ddc2 / 4-rs -485 wiring digital display wall clock guide page 46 appendix c - rs485 wiring diagrams rs485 data format the data string that sends the time to the ddc2 / ddc4 series wall clocks is formatted in such a manner that a utility can be written to achieve time updates from a personal computer...

  • Page 53

    Page 47 digital display wall clock guide ddc2 / 4-rs -485 wiring omcii to ddc2-rs / 4-rs pin signal signal jp4 connection 1 transmit data (-) transmit data (-) d- 2 transmit data (+) transmit data (+) d+ 8 signal ground signal ground gnd to other clocks blk blk 115vac local power omcii db9 female pl...

  • Page 54

    Ddc2 / 4-rs -485 wiring digital display wall clock guide page 48 ltr0 to ddc2-rs / 4-rs wire signal signal jp4 connection gray transmit data (-) transmit data (-) d- orange transmit data (+) transmit data (+) d+ black signal ground signal ground gnd blk blk 115vac local power to other clocks ltr0 fl...

  • Page 55

    Page 49 digital display wall clock guide ddc2 / 4-rs -485 wiring ltr4 / 8-512 to ddc2-rs / 4-rs terminal # signal signal jp4 connection 9 (d-) transmit data (-) transmit data (-) d- 8 (d+) transmit data (+) transmit data (+) d+ blk blk 115vac local power to other clocks ltr4 / 8-512 terminal connect...

  • Page 56

    Ddc-tc timer control panel digital display wall clock guide page 50 appendix d - ddc-tc timer control panel wiring the ddc-tc can be connected to the ddc series wall clock with a 6 conductor cat3 or cat5 network cable. The ddc-tc can be mounted up to 200 feet from the ddc series wall clock. The ddc-...

  • Page 57

    Page 51 digital display wall clock guide ddc-tc timer control panel installation the ddc-tc mounts directly to a standard, double-gang wall box. (not included) once the wiring has been attached, place the wires inside the double-gang wall box and mount the ddc-tc to the box with the four screws supp...

  • Page 58

    Ddc-tc timer control panel digital display wall clock guide page 52 operation as a count up timer to start the count: press count up to pause the count: press stop / continue to continue the count: press stop / continue to return to clock mode: press quit as a count down timer to set hours: press se...

  • Page 59

    Page 53 digital display wall clock guide specifications appendix e - ltr-gps satellite receiver / clock synchronizer lathem’s ltr-gps is a global positioning satellite receiver using 12-channels to access the accurate date and time signal transmitted each second by 24 satellites in geosynchronous or...

  • Page 60

    Warranty digital display wall clock guide page 54 the ltr-gps package includes: ltr-gps satellite synchronizer 115vac, 2.7w, 50/60hz power adapter active gps antenna with 25ft. Cable antenna mounting bracket and hardware installation and set-up guide separately, from lathem, for installer convenienc...

  • Page 61

    Page 55 digital display wall clock guide specifications connecting to a lathem ddc2-rs or ddc4-rs digital clock ddc2 -rs / ddc4 -rs.

  • Page 62

    Warranty digital display wall clock guide page 56 appendix f - specifications dimensions ddc2 4 7/8" h x 10 1/4" w x 3 1/8" d 12.4 cm h x 26.2 cm w x 7.9 cm d ddc4 6 3/4" h x 15 1/2" w x 3 1/8" d 17.1 cm h x 39 cm w x 7.9 cm d weight ddc2 3.2 lbs (1.451 kg) ddc4 9 lbs. (4.086 kg) display ddc2 1 3/4-...

  • Page 63

    Page 57 digital display wall clock guide specifications appendix g - warranty limited one-year limited warranty lathem warrants the hardware products described in this guide against defects in material and workmanship for a period of one year from date of original purchase from lathem or from an aut...