LAUER EPC PM 1200 User Manual

Manual is about: Elektronik Systeme LAUER Embedded PC User manual

Summary of EPC PM 1200

  • Page 1

    Cis-nr.: 360.610.0110 reg 10508/0605 version 2/09.05 © elektronik-systeme lauer gmbh & co. Kg user manual epc pm 1200 epc pm 1500 epc pm 1700 epc pm 2100 epc pm box.

  • Page 2

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 0-2 elektronik systeme lauer gmbh & co. Kg p.O box 1465 d-72604 nürtingen operating instructions: embedded pc pentium mobile issue: 01. September 2005 editor: jung operating instru...

  • Page 3: User Tips

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 0-3 user tips please read the manual prior to using for the first time and keep it in a safe place for future use. Target group the documented information in this manual refers to ...

  • Page 4: User Tips

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 0-4 user tips icons the following icons are used in the manual to mark certain paragraphs: danger means that death or severe injury will occur when the relevant precautionary measu...

  • Page 5: Contents

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 0-5 user tips 3 contents 5 preamble 6 certificates and guide lines 7 1 preparation 9 1.1 list hof supplied equipment ................................................... 9 1 prepara...

  • Page 6: Preamble

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 0-6 preamble elektronik-systeme lauer gmbh & co. Kg kelterstraße 59 d-72669 unterensingen tel. +49 (0) 7022 / 9660-0 fax +49 (0) 7022 / 9660-274 http://www.Lauer-systeme.Net our ph...

  • Page 7: Certificates and Guide Lines

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 0-7 certificates and guide lines the following applies for the products described in this documentation: emv-directives alternating - ac supply the appliances running on ac supply ...

  • Page 8

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 0-8.

  • Page 9: Preparation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 9 1 preparation 1.1 list hof supplied equipment the transport cardboard box contains the following parts and materials: cd with operating system. Driver software cd for all pre-ins...

  • Page 10: Preparation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 10 1 preparation 1.1.1 organisation driver-cd on the supplied driver cd you will find the available drivers necessary for your installation. • audio (onboard sound) • chipset • gra...

  • Page 11: Description

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 11 2 description 2.1 installation the installation of the ppc is independent of the display size, shown as follows: 1 frontunit 2 pc-unit 1 2.

  • Page 12: Description

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 12 2.2 display display sizes of 12", 15", 17"and 21" are available, alternatively with touch or keyboard and touch. Pure touch variants available in 12", 15", 17"and 21" touch/key ...

  • Page 13: Description

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 13 2.3 ports 24 v panel 2 description.

  • Page 14: Description

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 14 230 v panel 2 description.

  • Page 15: Description

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 15 2.4 motherboard – slots, memory module the panel-pc and the pc-module have 2 dimm slots for the main storage, 2 pci-slots. Further details on the motherboard can be found in the...

  • Page 16: Description

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 16 2 description.

  • Page 17: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 17 3 putting in to operation 3.1 power supply the embedded pc pentium mobile are available as ac-115/230v-power system or dc-24v-power system. Power supply system 24v dc the epc pm...

  • Page 18: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 18 power supply system 230 vac the epcpm is certified for the connection to protective grounded power supply after en60950. 1 supply connection 230 vac 2 earth screw 3.2 earthing s...

  • Page 19: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 19 3.3 assembly assembly the epc pm is to be inserted in a hf close housing or switchgear cabinet made of metal to dissipate the heat generated in the appliance a free space for ai...

  • Page 20: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 20 3.4 operating system supply incl. Operating system hard disk version: we offer our appliances with installed operating system software. In this case we opt for following install...

  • Page 21: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 21 3.5 bios-settings settings dfi-acp g5m100n: switch on the epc pm and press the [del] i.E. [entf]-button shown in the first screen image, to start the set up. 3 putting in to ope...

  • Page 22: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 22 settings for the mini-itx board dfi acp g5m100n: 1. Load “load optimized default“ and carry out the respective settings in the shown menus. Menü/untermenü menüpunkt einstellung ...

  • Page 23: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 23 3.6 important items regarding software installation to carry out a successful re-installation you have to observe the following items: • for the set up please use the supplied o...

  • Page 24: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 24 3.7 touch installation 6.10 windows 2000 / xp technical data: (check the bios entries when re-installing) • serial tsharc 12 touch-controller • com 3 (check the bios entries) • ...

  • Page 25: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 25 • follow the instructions on the monitor. Press [continue]. • accept the license provisions 3 putting in to operation.

  • Page 26: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 26 • select the „auto detect function“ or manually select the technical connection data. 3 putting in to operation.

  • Page 27: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 27 • press the [finalise]-button and follow the instructions for a re-start. • after a re-start of the operating system you will find amongst the programs the entry „hampshire cont...

  • Page 28: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 28 3.8 graphic board installation after conclusion the windows installation (chip set driver) and restart of the device, close the installation window for the automatic driver sear...

  • Page 29: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 29 3.9 installation lan-/network card proceed as follows to install the lan-/network card(s): • following the installation of the operating system and the chipset driver, the syste...

  • Page 30: Putting In to Operation

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 30 3 putting in to operation.

  • Page 31: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 31 4 service tools you can carry out the assembly with an allan key 2,5 and a phillips screw driver size 3. Preparation disconnect the appliance from the power supply. Attention! D...

  • Page 32: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 32 4.1 changing the fan to change the fan you have to remove the left hand part of the rear enclosure. To open the enclosure remove the marked screws with an allen key. Then lift t...

  • Page 33: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 33 please note the correct location of the cable prior to pulling the cable out so that the new fan can be plugged in correctly. Remove the protective cover of the fan and remove t...

  • Page 34: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 34 4.2 pci-board installation to install a pci-board the right hand side part of the rear enclosure has to be removed. To open the enclosure remove the marked screws with an allen ...

  • Page 35: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 35 a look at the opened appliance shows the 2 pci-slots and the board holder. Remove the slot cover of the desired slot to insert your pci-board. 4 service.

  • Page 36: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 36 unscrew the board holder. Insert your pci-board. Please ensure a correct fit at the lower edge of the slot. Screw your pci-board tight. 4 service.

  • Page 37: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 37 subsequently the board holder has to be re-fixed. To ensure an optimal use of the board holder, we suggest that you put wide boards in the lower slots and narrow boards in the u...

  • Page 38: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 38 4.3 memory expansion, -change to change the memory board you have to remove the left hand part of the rear enclosure. To open the enclosure remove the marked screws with an alle...

  • Page 39: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 39 put the enclosure to one side and you have a free view of the slots. Pull out ribbon cable (see arrow) and move it to the top. The picture shows a free and an occupied slot. If ...

  • Page 40: Service

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 40 if a memory board is changed then the holding brackets have to be pushed outwards simultaneously. The memory board is now loose and can be removed. Locate the memory board verti...

  • Page 41: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 41 5 technical data the following technical data divide on into cpu unit and display unit. Cpu-unit cpu long life cycle embedded board processor low power mobile cpu intel celeron-...

  • Page 42: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 42 display-unit ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ screen size (inch) 10,4" 12,1" 15,0" 17,0" 21,3" ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...

  • Page 43: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 43 5.1 detailed drawings 5.1.1 epc pm 1200 frontal view overall measurement: 364,0 x 296,0 mm front panel assembly aperture aperture size : 344,0 x 276,0 mm type of mounting with 8...

  • Page 44: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 44 view of the appliance’s underneath lateral view appliance’s rear view lateral view view of the equipment top side 5 technical data.

  • Page 45: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 45 5.1.2 epc pm 1500 frontal view overall measurement: 452,0 x 357,0 mm front panel assembly aperture aperture size : 429,0 x 334,0 mm type of mounting with10 pieces into the front...

  • Page 46: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 46 view of the appliance’s underneath lateral view appliance’s rear view lateral view view of the equipment top side 5 technical data.

  • Page 47: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 47 5.1.2 epc pm 1700 frontal view overall measurement: 480,0 x 377,0 mm front panel assembly aperture aperture size : 454,0 x 351,0 mm type of mounting with14 pieces into the front...

  • Page 48: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 48 view of the appliance’s underneath lateral view appliance’s rear view lateral view view of the equipment top side 5 technical data.

  • Page 49: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 49 5.1.3 epc pm 2100 frontal view overall measurement: 527,0 x 419,0 mm front panel assembly aperture aperture size : 498,0 x 390,0 mm type of mounting with14 pieces into the front...

  • Page 50: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 50 view of the appliance’s underneath rear view of the appliance lateral view 5 technical data.

  • Page 51: Technical Data

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 51 5.1.4 epc pm box view of the appliance’s underneath rear view of the appliance lateral view 5 technical data.

  • Page 52

    © elektronik-systeme lauer gmbh & co. Kg • kelterstr. 59 • 72669 unterensingen • tel. 07022/9660-0 • fax 07022/9660-103 52.