Lava Aire Aviator X2 Instruction Manual

Other manuals for Aviator X2: Owner's Manual
Manual is about: ELECTRIC COMMERCIAL GRADE PATIO COOLER

Summary of Aviator X2

  • Page 1

    Electric commercial grade patio cooler instructions manual.

  • Page 2

    @2012.11-v1.1 aviator x2 page 2 of 15 contents Ø instruction............................................................................ ....3 Ø outline drawing.......................................................................3 Ø wiring diagram...................................... ...............

  • Page 3

    @2012.11-v1.1 aviator x2 page 3 of 15 fan head mist regulating switch water tank wheels control panel pushing handle ■ instruction aviator x2 misting air coolers adopt user-friendly design and appearance. The mist particles (diameter of 10-25 microns) emitted by misting device will take away the hea...

  • Page 4: ■    Wiring Diagram

    @2012.11-v1.1 aviator x2 page 4 of 15 ■ wiring diagram aviator x2 aviator x4.

  • Page 5

    @2012.11-v1.1 aviator x2 page 5 of 15 ■ installation instructions 1、 wheels installation take out the water tank from the box, overturn it, and then fasten the 4 wheels on the corresponding position with 16 sets of m8x16 hex head cap screw, spring washer and flat washer. (picture 1) when using " aut...

  • Page 6

    @2012.11-v1.1 aviator x2 page 6 of 15 fasten by sucks installed beneath the pump. Fasten the level sensor with the nut into the corresponding trench. Make sure the floater is flapped down like the picture shows. 3、 combine main part and water tank lock the 4 wheels, and then place the main part on t...

  • Page 7

    @2012.11-v1.1 aviator x2 page 7 of 15 connect the blue outlet pipe to the quick coupling of the mist regulating switch, and then tie up the orange return pipe and blue outlet pipe with ribbon. (see picture 5) picture 5 connect the 2-core interface from the submersible pump and level sensor with the ...

  • Page 8

    @2012.11-v1.1 aviator x2 page 8 of 15 after ensuring all the cables are connected right, fasten two button positions to the fan body firstly, then fix the electric box with two 5x16 screws and flat washers (shown as picture 7). Installation completed. Picture 7 n checking after installation ² 1、inst...

  • Page 9

    @2012.11-v1.1 aviator x2 page 9 of 15 n trial operation after installation, fill the water tank with water to the depth of 20 cm. Then you can try to operate it. Manual adding water: insert a hose to the tank through the hole (as shown). Don’t go away while adding water. You can view the water level...

  • Page 10

    @2012.11-v1.1 aviator x2 page 10 of 15 electric control box: way of trial operation: 1. Power on, switch to the speed 1. The product would begin blowing. Observe whether the fan blows normally, by switching the speed 1 / 2 / 3. 2. Press the button “mist”, the centrifugal disc would begin rotating an...

  • Page 11

    @2012.11-v1.1 aviator x2 page 11 of 15 ■ attentions: please carefully read the following items: caution:the product must be connected to the power with leakage protection device. ¨ make sure firmly plugged ¨ be sure not to take off the plug while operating. Otherwise, it may cause electric shock or ...

  • Page 12

    @2012.11-v1.1 aviator x2 page 12 of 15 ■ attentions caution:the product must be connected to the power with leakage protection device. ◆ earthing: make sure the earthing wire is connected to specified earthing system of the construction. ◆ power off the product if you don’t use for a long time. ◆ pl...

  • Page 13

    @2012.11-v1.1 aviator x2 page 13 of 15 ■ common malfunction analysis and maintenance common malfunction analysis warning: wrong operation and maintenance will cause electric shock or a fire. Please contact the agent or dealer to repair the product by professionals. It can save your time and expense ...

  • Page 14: Maintenance

    @2012.11-v1.1 aviator x2 page 14 of 15 maintenance – water tank cleaning warning: ¨ to ensure the cleanness of the mist, the product should be cleaned before each use. ¨ before cleaning the product, stop it and unplug the power, otherwise there would be risk of electric shock. ¨ do not use high-pres...

  • Page 15

    @2012.11-v1.1 aviator x2 page 15 of 15 ² thoroughly cleaning ( suitable for cleaning after 60 hours’ operation) 1. Take the main body apart with the water tank. 1.1 loosen the 4 butterfly screws on the plate inside the tank (refer to the installation instruction—step 3 / picture 4) 1.2 take the main...

  • Page 16: Five-Year Limited Warranty

    16 the appliance has been manufactured under the highest standards of quality and workmanship. We warrant to the original consumer purchaser that all aspects of this product will be free of defects in material and workmanship for five (5) year from the date of purchase. A replacement for any defecti...

  • Page 17: Lava Aire Italia

    Manufactured by: lava aire italia t. 888.779.Lava t. 888.779.5282 vernon, ca 90058 www.Lavaaire.Com dear valued lava aire italia customer, thank you for purchasing a lava aire italia product! Congratulations and welcome to the lava aire italia family. Our mission is to design and construct beautiful...