Maintenance manual for technical assistance - LB GUZZINI
Manual code 10083088 / Rel. 0.00 / January 2008
- Hydraulic group
- To remove the electrovalve (
30) you must disconnect
the relevant faston then unscrew the two screws (
31).
31
25
- To remove the valve (
25) you should remove the pipe
(
27), disconnect the pipe (28) and remove the spring
(
29) using a pliers.
30
27
29
28
31
- Remove the two faston from the pump (
32).
- Disconnect the pump connector (
33) using a pliers.
33
32
- Shift the sheathing (
34) and remove the spring (35)
using a pliers (
35).
34
35