LavorPro FF 125 User's Manual & Operating Instructions - Table of Contents

Summary of FF 125

  • Page 1

    Model numbers ff 45 / ff 70 / ff 125 / ff 175 / ff 215 © 2017 lavorwash australia pty ltd 7/76 rushdale street, knoxfield, vic. 3180 user’s manual & operating instructions consumer: read and save these instructions general hazard warning: read and understand all of the instructions in this manual be...

  • Page 2: Table of Contents

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 1 table of contents safety information.............................................1-2 features and specifications.................................3 ff 45 and f...

  • Page 3: Safety Information

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 2 safety information the products described in this manual are paraffin direct-fired, forced air heaters. Paraffin forced air heaters are primarily intended for...

  • Page 4: Specifications

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 3 specifications features model # ff 45 ff 70 ff 125 ff 175 ff 215 rating: kw 13.0 20.5 36.6 51.2 63.0 fuel consumption: l/hr 1.32 2.00 3.60 5.07 6.17 fuel tank...

  • Page 5: Assembly Instructions

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 4 assembly instructions models: ff 45 / ff 70 what’s in the box cord wraps (2) carry handle (1) black screws (4) carry handle assembly 1. Align holes in the upp...

  • Page 6: Assembly Instructions

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 5 - remove the heater and all packaging materials from the shipping carton. Tools needed: - phillips head screw driver - 8 mm open end wrench - 19 mm open end w...

  • Page 7: Assembly Instructions

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual assembly instructions models: ff 125 / ff 175 / ff 215 1. Insert axle through holes in wheel support. 2. Slide washer, then spacer onto axle. 3. Slide wheel ont...

  • Page 8: Operation

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual operation fueling the heater: paraffin for optimal performance of this heater, it is strongly suggested that paraffin be used. Paraffin has been refined to virt...

  • Page 9: Operation

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual operation starting the heater: (ignition) 1. Fill the tank with paraffin or other approved fuel until needle on fuel gauge points to “f”. 2. Replace fuel cap an...

  • Page 10: Maintenance

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual maintenance long term storage: models ff 45 / ff 70: 1. Use an approved siphon to drain fuel through the fuel cap opening. Models ff 125 / ff 175 / ff 215: 1. D...

  • Page 11: Maintenance

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual maintenance service (continued): fan blades: blades should be cleaned at least once per heating season, depending on conditions. Remove all accumulated dust and...

  • Page 12: Wiring Diagram

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual wiring diagram control pcb power lamp (led) cn1 red red black blue black black blue red earth green spark plug ignitor pump motor capacitor 3.5uf/450vac fan 1 f...

  • Page 13: Troubleshooting Guide

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 12 troubleshooting guide problem possible cause solution heater ignites, but main pcb shuts off after a short period of time. Lamp flickers and led display show...

  • Page 14: Exploded View

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 13 17 14 16 11 15 12 40 42 46 34 4 19 17 3 5 35 8 7 1 2** 9 28 29 27 32 21 22 23 31 26 30 24 18 55** 47* 49** 50 39 38 6 45 44 43 36 10 41 20 33 37 52** 51** 53...

  • Page 15: Parts List

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 1 fuel tank assembly 70-002-0100 70-002-0100 70-002-0200 70-002-0300 70-002-0300 2 drain plug – – 70-002-0105 70-002-0105 70-002-0105 3 fuel gauge assembly 70-0...

  • Page 16

    Never leave heater unattended while burning or while connected to a power source © 2017, lavorwash kerosene forced air heater user’s manual 15 ____________________________________________________________ ____________________________________________________________ ___________________________________...