Operation of the Model DA924 Digital to Analog Converter requires the use of two
push button switches located on the front panel.
POLARITY inverts the absolute polarity of the signal.
INPUT SELECT
controls selection of digital inputs to the DAC.
Input signal selection
The INPUT SELECT lamp indicators show the selected input signal. Pressing the
INPUT SELECT push button moves to the next input position.
Holding the INPUT SELECT button for more then a second makes the DA924 go into
search mode: the unit will step through the inputs but will skip the inactive input connectors
(where no signal is present).
Holding the INPUT SELECT button for more than one second switches between manual
input selection and the input search mode, or visa versa. The mode selected is retained
when power is removed.
Input signal connection
The unit can be connected to one, two or three digital input connectors located on the rear
panel:
AES/EBU input to the XLR connector designated as AES INPUT 1
AES/EBU input to the XLR connector designated as AES INPUT 2
SPDIF (consumer format) input to IEC INPUT.